Blaze King
,
Royal Guardian,
Model RGT-3001
OWNER'S INSTALLATION AND OPERATION MANUAL
Page 12
Date Printed: Wednesday, November 07, 2012
OM-RGT.PUB
Version 1.03
PREPARATION AND ASSEMBLY
WARNING
IMPROPER ASSEMBLY AND/OR INSTALLATION OF YOUR BLAZE KING WOOD STOVE OR FAILURE
TO OPERATE IT ACCORDING TO THE GUIDELINES DETAILED IN THESE INSTRUCTIONS, WILL VOID THE
STOVE WARRANTY, CAN CAUSE A HOUSE OR CHIMNEY FIRE, AND MAY ENDANGER YOU FAMILY. FOR
YOUR SAFETY, FOLLOW THE ASSEMBLY AND INSTALLATION INSTRUCTIONS CAREFULLY. CONTACT LOCAL
BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTIONS IN YOUR AREA.
PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW STOVE
This Blaze King Model RGT-3001 Wood stove is Listed by INTERTEK TESTING SERVICES, ONLY if: it is connected
to a suitable masonry chimney, or a 6 Listed Residential Type and Building Heating Appliance Type Chimney System
(hereafter referred to as Chimney) and minimum clearances to combustible (burnable) materials are observed. See
CHIMNEY and CHIMNEY CONNECTOR, and Table 1, Page 19 for minimum clearances.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
TOOLS NEEDED FOR INSTALLATION
If you are planning to install this stove yourself, you will need the tools listed below. Consult the chimney and chimney
connector manufacturer's installation instructions for tools needed for installation.
a. 1/4 Wrench, Nut driver, or Socket with Handle
b. Medium Flat Blade Screwdriver and Square Screwdriver.
c. Tape
measure.
d. Carpenters
Level.
e. See Mobile Home section for tools needed for Mobile Home stove installations.
PLANNING FOR YOUR STOVE PLACEMENT
As you plan your installation, consider the following:
a. Stove should be placed in the most central location in the home. Consider safety, convenience, traffic flow, and the
fact that the stove will need a chimney and chimney connector
b. MINIMUM CLEARANCES SHOWN IN FIGURES 21-26, PAGE 20 ARE TO PREVENT WALLS AND CEILINGS
FROM CATCHING ON FIRE.
c. The dimensions and position of the Floor Protector. See pages 19 & 20
d. The type of chimney system to be used. See page 19.
Electrical Power. (Optional) The stove can be equipped with a fan assembly and a seven foot electrical cord. Do not
route the cord in front of the stove.
REDUCED WALL CLEARANCES
The stove and chimney connector may be placed closer to the wall than shown in Figures 21-26, Page 20 if the wall is
properly protected. The two wall protection systems described on pg. 11 & 12, allow a reduced clearance from the wall
to the stove.
CHECK YOUR CHIMNEY
Before connecting any wood-burning unit to an existing chimney, inspect the chimney to be sure that it is in good
condition. There must be no cracks or holes. The cross-sectional area must not be less than that of the flue collar (6"
diameter 28.27 square inches). A proper chimney is crucial for safe, satisfactory operation of any wood heating
system. Relining or rebuilding may be necessary to make the chimney safe, efficient, and in conformity with local
codes.
Masonry chimneys that have a very large cross-section (100 square inches or more) may experience poor draft and
may require relining to reduce the cross-section and provide a proper draft.
This is also an ideal time to clean the existing chimney. For peak efficiency, a clean chimney flue is essential. A
qualified professional chimney sweep can perform both inspection and cleaning. If you choose to clean your own
chimney, use the proper tools. Homemade cleaners, such as chains, may damage your chimney.
Be sure the Ash Clean-Out door for the masonry chimney is closed tightly. This door may be in the wall in the room
below the chimney or outside near the ground level of the chimney. This is frequently overlooked, and can cause
severe drafting problems in masonry chimney installations.
The chimney MUST extend above the roof at least three feet & two feet above any area of the roof within ten feet of the
termination of the chimney.
If the chimney is a prefabricated metal chimney system be sure chimney pipe is attached, together and, to the wood-
burning unit with a minimum of three (3) screws securing each connection.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.