180-CL2118-SP v1.00
May 22, 2018
Page 25
Clarity CL2118 SP
INSTALLATION
9. If installing the optional log set (
Fig.17
) refer to
installation instructions supplied with log set, if
not continue below.
10. Repeat “
GLASS DOOR REMOVAL
” steps in
reverse order to complete initial setup.
Fig.17
VENT TERMINATION LOCATION
• Establish a suitable vent termination location (see
“VENT TERMINATION RESTRICTIONS”
)
• In heavy snowfall areas make sure vent termination is located where it will not be blocked by snowfall or
snow from snow removal equipment.
• Locate vent termination away from plants, bushes, or any other object on or near the vent termination that
will interfere or obstruct the air fl ow around it.
• DO NOT recess vent termination into walls, sidings, or planters.
• Vent terminations located below 7 ft (2130 mm) from grade level or anywhere that it is a burn hazard to the
public, such as patios and balconies, must be protected with an approved termination cage.