INSTALLATION INSTRUCTIONS cont.
MOBILE HOME (AND RESIDENTIAL ALCOVE INSTALLATIONS)
Use double wall listed pipe, side shields, and rear shield (See next page for kits and part numbers). Mobile home
installations also requires an outside air kit #Z1526. Th
ey are easiest to mount before the stove is installed.
See instructions packed with each kit.
NOTE: UNDER NO CIRCUMSTANCES SHOULD THE FRESH
AIR TUBE EVER BE INSTALLED HIGHER THAN THE BOTTOM OF THE APPLIANCE FIREBOX
FLOOR
When a metal prefabricated chimney is used, the manufacturer’s installation instructions must be followed
precisely. You must also purchase (from the same manufacturer) and install the ceiling support package, fi re
stops (when needed), insulation shield, roof fl ashing, chimney cap, etc. Maintain the proper clearance to the
structure as recommended by the manufacturer.
Chimney connector must be double wall close clearance type with either ULC629 or ULCS610 designation.
Single wall pipe is not allowed in Mobile Homes or in Alcove Installations. Insulated chimney components
must be a listed factory built chimney suitable for use with solid fuels and conforming to, ULC629 in Canada or
UL-103HT in the USA. For Mobile home, the chimney needs to be removable to allow for transportation of the
mobile home.
DO NOT INSTALL IN SLEEPING ROOM. THE STRUCTURAL INTEGRITY OF THE MOBILE
HOME FLOOR, WALL AND CEILING / ROOF MUST BE MAINTAINED.
In mobile home installations the stove must be
securely fastened to the fl oor using the lag bolts
provided in the outside air kit:
1. Position the stove on the fl oor protector so that
the minimum clearances are met.
2. Remove the back pedestal cover.
3. Drill down through the holes in the base of the
stove, penetrating both the fl oor protector and
the fl oor of the home.
4. Place two lag screws through the holes and fasten
them securely to the fl oor of the structure. (Make
sure the stove cannot shift or move.)
ALSO, a #8 ground wire must be attached to the
stove and an appropriate ground.