OM-BRII90 E V1.03 wo739
July 14, 2015
Page 12
BRII/90
INSTALLATION INSTRUCTIONS cont.
MINIMUM CLEARANCES for BRII/90
Residential Installations
A
B
C
D
E
F
Single wall pipe (24 MSG Black).
15”
381 mm
15”
381 mm
28.75”
731 mm
22”
559 mm
15”
381 mm
28.875”
734 mm
Listed double wall pipe - close clearances. Use side shields and rear
shield. (Must use for mobile / manufactured home installations. Alcove
Installation and close clearance installations)
14”
356 mm
8”
204 mm
27.75”
705 mm
15"
381 mm
8”
203 mm
21.875”
556 mm
Check with local codes and pipe manufacturer for pipe clearances. In Canada, 18” clearances from single wall pipe is required.
Mobile home and alcove installations must use double wall listed pipe, side shields, and rear shield.
Mobile home installations also require an outside air kit #Z1526
2"
D
C
A
G
H
G
B
I
G = 5 3/8” (137mm) in USA
8” (203mm) in Canada
H = 16” (406mm) in USA
18” (456mm) in Canada
I = 0” (0mm) in USA
8” (203mm) in Canada
K = 18” (456mm) for single wall pipe in Canada
Ember protection shield (not required to have an insulation value)
is to be listed under UL 1618-2009 (type 1) and must have a minimum size of:
In USA: 38 1/4”wide x 33 3/4”deep (972 x 858 mm)
In Canada: 43 1/2”wide x 43 3/4”deep (1105 x 1112 mm)
Min. Alcove minimum width 55 1/2”, maximum depth 32”, minimum height above stove top 36”
This stove must be installed in compliance with all local codes and regulations.