Blaze King BRIARWOD BRII/90 Скачать руководство пользователя страница 1

OM-BRII90 E V1.03 wo739

July 14, 2015

Th

  e authority having jurisdiction (such a municipal building department, fi re department, etc.) should be 

consulted before installation to determine the need to obtain a permit.

Pour la version française de nos manuels S.V.P. vous référez à notre site web: www.blazeking.com

Manufactured By

Valley Comfort Systems Inc.

, 1290 Commercial Way, Penticton, BC, V2A 3H5, Canada

Phone: 250-493-7444 

 Fax: 250-493-5833 

 www.blazeking.com 

 [email protected]

OPERATION & INSTALLATION MANUAL

Installer: Please complete the details on the back cover

and leave this manual with the homeowner.

Homeowner: Please SAVE THESE INSTRUCTIONS for future reference.

BRIARWOD BRII/90

SOLID FUEL STOVE

Th

  is heater meets the 2015 U.S. Environmental Protection Agency’s particulate emission limits for wood heaters sold aft er May 15, 2015.

Содержание BRIARWOD BRII/90

Страница 1: ...tured By Valley Comfort Systems Inc 1290 Commercial Way Penticton BC V2A 3H5 Canada Phone 250 493 7444 Fax 250 493 5833 www blazeking com info blazeking com OPERATION INSTALLATION MANUAL Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please SAVE THESE INSTRUCTIONS for future reference BRIARWOD BRII 90 SOLID FUEL STOVE This heater meets th...

Страница 2: ...11 FLOOR PROTECTION 11 MINIMUM CLEARANCES for BRII 90 12 COMBUSTION AIR 13 DRAFT 13 ROLE OF THE CHIMNEY 13 VENTING SYSTEMS 14 MOBILE HOME AND RESIDENTIAL ALCOVE INSTALLATIONS 17 OPTIONAL ACCESSORIES 18 OPERATING INSTRUCTIONS ___________________________________________________ 20 YOUR FIRST FIRE 20 SELECTING WOOD 20 HOW TO USE MOISTURE METERS 21 EFFICIENCY 21 LIGHTING THE FIRE 22 RELOADING PROCEDUR...

Страница 3: ...CHIMNEY DRAFTS 29 OPTIONAL FAN ASSEMBLY 29 TROUBLESHOOTING__________________________________________________________ 30 WARRANTY _________________________________________________________________ 34 INSTALLER NOTES____________________________________________________________ 40 ...

Страница 4: ...h guards to protect children from hot surfaces These guards must be fastened to a wall and or to the floor Any safety guard removed for servicing must be replaced prior to operating the appliance Under no circumstances should this appliance be modified This appliance must not be connected to a chimney flue pipe servicing a separate solid fuel burning appliance Do not operate the appliance with the...

Страница 5: ...ed and listed UL 1482 1988 and ULC S627 M93 by Intertek testing laboratories This manual describes the installation and operation of the Briarwood BRII 90 wood heater This heater is certified to comply with the 2015 U S Environmental Protection Agency s particulate emission limits for wood heaters sold after May 15 2015 Under specific test conditions this heater has been shown to deliver heat at r...

Страница 6: ...OM BRII90 E V1 03 wo739 July 14 2015 Page 6 BRII 90 APPLIANCE DIMENSIONS Briarwood PRODUCT INFORMATION Z RSWLRQDO IDQV ...

Страница 7: ...M CLEARANCES TO COMBUSTIBLES See owners manual for complete description of all requirements Mobile Home and Alcove Installations must use double wall listed pipe side shields and rear shield Mobile Home Installations require Outside Combustion Air Kit Z1526 Floor protection may be any non combustible material or Listed Floor Protector and must extend at least 18 406 mm in front of the loading door...

Страница 8: ...y fire to clean the flue When installed in a mobile home this appliance must be bolted to the floor and provided with outside air WARNING DO NOT INSTALL IN A SLEEPING ROOM CAUTION THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR WALL AND CEILING ROOF MUST BE MAINTAINED Check with local building officials If the Optional Fan Kit is installed connect this unit to a properly grounded 110 volt electr...

Страница 9: ...th a tightly fitting lid and moved outdoors immediately If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders have thoroughly cooled Other waste shall not be placed in this container SAFETY PRECAUTIONS cont It is recommended to install smoke and carbon monoxide detectors where heaters are installed Install at...

Страница 10: ...LES UNDER THE APPLIANCE WOOD PAPER etc Contact local building officials to obtain a permit and information on any installation restriction or inspection requirements in your area Notify your insurance company as well SAFETY PRECAUTIONS cont This appliance is designed and approved for burning cord wood only DO NOT burn trash garbage artificial or paper logs gift wrappings coal lighter fluids chemic...

Страница 11: ...for the installation or maintenance of the appliance and assumes no responsibility of any consequential damage s PARTS INCLUDED WITH THE BRIARWOOD 1 Poker 2 Manual kit w warranty cards fire starter OPTIONAL EQUIPMENT 1 Fan kit Z1514 2 Rear shield ZRSBRII 3 Side shields ZSSBRII requires rear sheild DECORATIVE OPTIONS 1 Door trim kit gold 2 Door trim kit satin BEFORE INSTALLING THIS APPLIANCE CONTAC...

Страница 12: ...ome and alcove installations must use double wall listed pipe side shields and rear shield Mobile home installations also require an outside air kit Z1526 2 D C A G H G B I G 5 3 8 137mm in USA 8 203mm in Canada H 16 406mm in USA 18 456mm in Canada I 0 0mm in USA 8 203mm in Canada K 18 456mm for single wall pipe in Canada Ember protection shield not required to have an insulation value is to be li...

Страница 13: ...it unsafe to operate the stove and will void manufacturers warranty ROLE OF THE CHIMNEY Without a proper installed chimney this appliance will not burn correctly The role of the chimney is to pull the proper amount of air into the firebox for the purpose of complete combustion Incomplete combustion will lead to more smoke and pollution of the outside air A proper operating chimney will allow the u...

Страница 14: ...ect the safe operation of both appliances and will void the stove warranty You must comply with the local authority having jurisdiction and or in Canada CSA installation standard B365 M87 The chimney connector must be 8 diameter 24 MSG Black Blue steel Do not use aluminum or galvanized steel They cannot properly withstand the extreme temperatures of a wood fire The chimney connector between the st...

Страница 15: ...od is to install the chimney inside the residence through the ceiling s and the roof The other method is to install an exterior chimney that runs up the outside of the residence not recommended If it is necessary to run the chimney outside build an outside chase around the chimney The chimney must be the required height above the roof or other obstruction for safety and for proper draft operation ...

Страница 16: ...or The resulting space must remain empty A flush mounted sheet metal cover may be used on one side only If covers are to be used on both sides each cover must be mounted on noncombustible spacers at least 1 clear of the wall Blaze King recommends the use of a Stainless steel liner preferably insulated inside a masonry chimney This to maintain proper draft and overall better operation of the unit Y...

Страница 17: ...le wall close clearance type with either ULC629 or ULCS610 designation Single wall pipe is not allowed in Mobile Homes or in Alcove Installations Insulated chimney components must be a listed factory built chimney suitable for use with solid fuels and conforming to ULC629 in Canada or UL 103HT in the USA For Mobile home the chimney needs to be removable to allow for transportation of the mobile ho...

Страница 18: ...osition INSTALLATION See instructions included with fan kit ELECTRICAL CONNECTION Your Blaze King fan kit is equipped with a three prong grounded plug to decrease shock hazard THIS PLUG SHOULD BE INSERTED DIRECTLY INTO A PROPERLY GROUNDED THREE HOLE RECEPTACLE DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THIS PLUG Do not route the power cord in front or under the stove OUTSIDE AIR KIT P N Z1526 R...

Страница 19: ...stove installation or to change it out follow these steps DOOR IS HEAVY PLEASE HOLD FIRMLY INSTALLATION 1 Insert the top of door hinge rod into the top hinge hole on the firebox 2 Lower door onto bottom hinge hole NOTE Ifyourdoor hasagoldorsilverplatingonit pleasefollowtheinstructions on the PLATED DOOR TRIM CARE card found in the manual pack ...

Страница 20: ...isture content of 20 or lower It takes a great deal of energy to evaporate the moisture contained in green wood and that energy will not be heating your house Also green or wet wood will greatly increase creosote problems The only accurate method to determine moisture content in wood is to use a moisture meter Never burn salt water driftwood It is very corrosive and will damage the firebox Burning...

Страница 21: ...esting contains between 19 25 water moisture included in the total calculated fuel weight Other test methods such as LHV or Low Heating Value does not take the water moisture into account Annual Fuel Utilization Efficiency AFUE attempts to represent the actual season long average efficiency of an appliance HHV is the actual calculated average efficiency obtained under test conditions Using correct...

Страница 22: ...for 20 to 30 minutes after every refuelling this will help to condition the wood load for optimum combustion During the start up of a cold stove a HIGH fire must be maintained for at least 20 30 minutes This ensures that the stove and fuel are all stabilized at proper operating temperatures If the fire is allowed to die down immediately draft control set to LOW too soon it may go out 10 The fan if...

Страница 23: ...ecide to light a fire in the spring and fall or when the outside temperature is milder perhaps 55 F to 70 F 13 C to 21 C As you light the fire with the loading door open you may notice spillage this is when a small amount of smoke comes back into the living space When your fire begins to warm the chimney and the draft improves spillage is greatly reduced After a short period of time you can adjust...

Страница 24: ... of the house to see if any part has become hot enough to catch fire If necessary spray with a fire extinguisher or water from a garden hose 4 Do not operate the appliance again until you are certain the chimney has not been damaged CREOSOTE FORMATION AND REMOVAL When wood is burned slowly it produces tar and other organic vapors which combine with expelled moisture to form creosote These vapors c...

Страница 25: ...AGE OR BASEMENT HOT ASHES WILL GENERATE CARBON MONOXIDE AND OR FLAMMABLE GASES THESE GASES MAY CAUSE SUFFOCATION AND POSSIBLE DEATH CHIMNEY MAINTENANCE The most efficient method to sweep the chimney is using a hard brush Brush downwards so soot and creosote residues will come off the inner surface and fall to the bottom of the chimney where they can be removed easily The chimney must be checked re...

Страница 26: ... 8 fiber glass gasket ready to re install as well as high temperature adhesive See your Blaze King dealer 2 Be sure the fire is out and the stove has cooled down The door should be removed by lifting up and out off of the hinge pins Then lay the door flat 3 With a pair of pliers pull the old door gasket out of the channel and dispose of it 4 Thoroughly clean out the channel so the new silicone adh...

Страница 27: ...l fasteners Ensure the glass is parallel to the frame and tighten the fasteners evenly 5 Follow steps on page 26 LOADING DOOR GASKET REPLACEMENT MAINTENANCE cont DOOR GLASS CLEANING The best way to keep the glass clean is to leave the stove on high burn for a period of time after each reloading The moisture which is driven from a new load of wood contributes much of the creosote on the inside of t...

Страница 28: ...3 if necessary To lossen the door seal 1 Open the loading door 2 Rotate the handle clockwise one rotation Fig B 3 Repeat paper test see LOADING DOOR GASKET INSPECTION on page 37 4 Repeat steps 1 3 if necessary DO NOT OPERATE THIS WOOD STOVE IF THE DOOR GASKET IS MISSING OR DAMAGED DANGEROUS OVER FIRING CAN OCCUR WHICH CAN DAMAGE THE APPLIANCE OR IGNITE CREOSOTE IN THE CHIMNEY POSSIBLY CAUSING A HO...

Страница 29: ...he chimney connector by using a sheet metal screw of proper size Recommended draft is 02 03 in w c at medium fire and 05 in on high burn Too little draft results in a sluggish fire and smoke spillage when the stove door is opened Too much draft over 0 06 in w c on high burn makes it unsafe to operate the stove and will void manufacturers warranty OPTIONAL FAN ASSEMBLY Routine maintenance of the OP...

Страница 30: ... chimney and flue connector inspected by a certified chimney sweep A damaged masonry chimney should be repaired or rebuilt A prefabricated chimney factory built that is damaged should be replaced Any damage to the flue connector should be corrected before the system is used again Possible causes of a chimney fire and remedies for those causes can be found further in this section Excessive Creosote...

Страница 31: ...is a fire hazard and demands immediate attention Poor draft caused by an oversize flue single wall pipe to many elbows etc Measure draft with Manometer See DRAFTS Consult your Blaze King dealer or a chimney sweep PROBLEM Door glass quickly becomes coated with creosote CAUSE LOW draft control setting SOLUTION Slide the draft control to HIGH during the first 20 30 minutes or until the fire is well e...

Страница 32: ...I 90 REPLACEMENT PARTS cont ITEM NO PART NUMBER DESCRIPTION QTY 1 0186A 6ft Gasket 7 8 hard rope for Briarwood 1 2 0254AS 6ft 1 8 window gasket 1 3 0730 Robax Glass 10 5 8 x 21 5 8 1 4 ZBR518 Door without glass 1 ZBR518P C Door with glass no handle 1 ...

Страница 33: ...OM BRII90 E V1 03 wo739 July 14 2015 Page 33 BRII 90 REPLACEMENT PARTS cont Briarwood Brick Layout 7 0 12 3 57 180 5 47 6L H ULFN 6 6L H ULFN 6L H ULFN 6L H ULFN ...

Страница 34: ...f America or Canada Warranty starts with date of purchase by the original owner End User except as noted for replacement parts Warranty Period Components Covered Parts Labor Wood 1 Year X All parts materials and surface finishes flaking and peeling Subject to Conditions Exclusion and Limitations listed 2 Years X Fan assemblies and motors thermal sensors door handle metal components 5 Years 2 Years...

Страница 35: ...and no claim shall be made against the manufacturer on any oral warranty or representation All claims under this Limited Warranty must be made in writing by your dealer 2 Any stove or part thereof that is repaired or replaced during the Limited Warranty period will be warranted under the terms of the Limited Warranty for a period not exceeding the remaining term of the original Limited Warranty or...

Страница 36: ...rom Blaze King The use of such products may nullify the Limited Warranty on this stove If unsure as to the extent of this Limited Warranty contact your authorized Blaze King dealer before installation 8 Blaze King will not be responsible for inadequate performance caused by environmental conditions 9 The Limited Warranty does not cover installation and operational related problems such as use of d...

Страница 37: ...s described in this document provided however that the purchaser shall pay the following percentage of the then current retail cost of the repair or the replacement according to the year after purchase in the which the defect is brought to the attention of Blaze King During the 2nd year purchaser pays 20 3rd year purchaser pays 40 4th year purchaser pays 60 5th year purchaser pays 80 25 If a defec...

Страница 38: ...OM BRII90 E V1 03 wo739 July 14 2015 Page 38 BRII 90 NOTES ...

Страница 39: ...OM BRII90 E V1 03 wo739 July 14 2015 Page 39 BRII 90 NOTES ...

Страница 40: ...__________________________________________ Installer print _______________________________________________________________ Installer sign _______________________________________________________________ Phone ____________________________________________________________________ Date Installed ________________________________________________________________ Serial No _________________________________...

Отзывы: