20. The Limited Warranty is automatically voided if the stove’s serial number has been removed or altered in any 

way. If the stove is used for commercial purposes, it is excluded from the Limited Warranty. 

21. No dealer, distributor, or similar person has the authority to represent or warrant Blaze King Products beyond the 

terms contained within the Limited Warranty. Blaze King assumes no liability for such warranties or representations. 
22. Blaze King will not cover the cost of the removal or re-installation of the stove, hearth, facing, mantels, venting 

or other components. 

23. Labor to replace or repair items under this Limited Warranty will be covered per our warranty service fee 

reimbursement and labor rates are set per component schedule. Labor rates vary from location to location and as 

such total labor costs may not be covered. Please consult with your dealer or service technician for any additional 

charges such as travel time or additional labor charges that may apply.

 

24. For parts of the Blaze King woodstove or fireplace insert warranted beyond the first year, the five year limited 
warranty will have the same obligations as described in this document, provided, however that the purchaser shall 
pay the following percentage of the then current retail cost of the repair or the replacement, according to the year 
after purchase in the which the defect is brought to the attention of Blaze King.*** During the 2

nd

 year----purchaser 

pays 20%.  
3

rd

 year ----purchaser pays 40%.  4

th

 year -----purchaser pays 60%. 5

th

 year---- purchaser pays 80%.

 

25. If a defect or problem is determined by Blaze King to be non warrantable, Blaze King is not liable for travel costs 
for service work. In the event of in-home repair work, the customer will pay any in-home travel fees or service 
charges required by the Authorized Dealer. 
26. At no time will Blaze King be liable for any consequential damages which exceed the purchase price of the unit. 
Blaze King has no obligation to enhance or modify any stove once manufactured (example: as a stove model 
evolves, field modifications or upgrades will not be performed). 
27. This Limited Warranty is applicable only to the original purchaser and it is non-transferable. 
28. This warranty only covers Blaze King Products that are purchased through an authorized Blaze King dealer. 
29. If for any reason any section of the Limited Warranty is declared invalid, the balance of the warranty remains in 
effect and all other clauses shall remain in effect. 
30. The Limited Warranty is the only warranty supplied by Blaze King, the manufacturer of the stove. All other 
warranties, whether express or implied, are hereby expressly disclaimed and the purchaser’s recourse is expressly 
limited to the Limited Warranty. 
31. Blaze King and its employees or representatives will not assume any liability for damages, either directly or 
indirectly, caused by improper usage, operation, installation, servicing or maintenance of this stove. 
32. Blaze King reserves the right to make changes without notice. Please complete and mail the warranty 
registration card and have the installer fill in the installation data sheet in the back of the manual for warranty and 
future reference. 
33. Blaze King is responsible for stocking parts for a maximum of seven (7) years after discontinuing the 
manufacture or incorporation of the item into its products. An exception to this would be if an OEM supplier is not 
able to supply a part. 

Warranty cont. 

Содержание BRIARWOD BRII/90

Страница 1: ...THESE INSTRUCTIONS FOR FUTURE REFERENCE LISTED BY Valley Comfort Systems Inc 1290 Commercial Way Penticton BC V2A 3H5 CANADA Phone 250 493 7444 Fax 250 493 5833 Blaze King Industries 146 A Street Walla Walla WA 99362 U S A Phone 509 522 2730 Fax 509 522 9803 Manufactured By Blaze King Pour la version française de nos manuels S V P vous référez à notre site web www blazeking com ...

Страница 2: ...by a qualified licensed installer have it checked by your local inspector Disregarding inspection and code requirements may jeopardize your homeowner s insurance Since some insurance carriers require notification of a stove installation you should contact your insurance agent We want your stove to give you many years of trouble free operation While we have made every effort to make these instructi...

Страница 3: ...imney Draft 14 Chimney height 14 Chimney requirements 14 Chimney Installation Masonry Chimney 15 Mobile Home Installation Instructions 16 Grounding 16 Chimney Height 16 Outside Air 16 Floor Protection 16 Attaching Stove to Floor 16 Operation 17 Grates 17 First Fire 17 Curing Paint 17 Starting Fire 17 Controls 17 Do Not Burn 17 Heat Output 17 Do Not Over fire 17 Accessories Installation Fan Kit and...

Страница 4: ...owner End User except as noted for replacement parts Warranty Period Components Covered Parts Labor Wood 1 Year X All parts materials and surface finishes flaking and peeling Subject to Conditions Exclusion and Limitations listed 2 Years X Fan assemblies and motors thermal sen sors catalytic thermometer bi metallic thermostat assembly 5 Years 2 Year X Firebox Heat Exchanger Bypass Door Steel Compo...

Страница 5: ...aser Please see the exclusions and limitation section below as certain restrictions and exclusions apply to this warranty How the Warranty Works 1 All warranties by the manufacturer are set herein and no claim shall be made against the manufacturer on any oral warranty or representation All claims under this Limited Warranty must be made in writing by your dealer 2 Any stove or part thereof that i...

Страница 6: ...environmental conditions Environmental conditions include but are not limited to nearby trees buildings roof tops wind hills mountains inadequate venting or ventilation excessive offsets negative air pressures or other influences caused by mechanical systems such as furnaces fans clothes dryers etc 11 The Limited Warranty does not cover damage caused by burning salt saturated wood corrosive driftw...

Страница 7: ...King to be non warrantable Blaze King is not liable for travel costs for service work In the event of in home repair work the customer will pay any in home travel fees or service charges required by the Authorized Dealer 26 At no time will Blaze King be liable for any consequential damages which exceed the purchase price of the unit Blaze King has no obligation to enhance or modify any stove once ...

Страница 8: ...TIBLES See owners manual for complete description of all requirements Mobile Home and Alcove Installations must use double wall listed pipe side shields and rear shield Mobile Home Installations require Outside Combustion Air Kit Z1526 Floor protection may be any non combustible material or Listed Floor Protector and must extend at least 18 406 mm in front of the loading door opening Minimum size ...

Страница 9: ...ST HOME FIRES CAUSED BY WOODBURNING STOVES ARE THE RESULT OF IMPROPER INSTALLATION AND OPERATION READ ALL INSTRUCTIONS THOROUGHLY BEFORE INSTALLING AND OPERATING YOUR Briarwood II STOVE SAVE THESE INSTRUCTIONS SAFETY PRECAUTIONS 1 CONSULT YOUR LOCAL BUILDING INSPECTOR TO ENSURE YOUR INSTALLATION COMPLIES WITH BUILDING AND FIRE CODES 2 Design your installation with safety as the primary considerati...

Страница 10: ...ely obtain a copy of the National Fire Protection Association publication Using Coal and Wood stoves Safely NFPA Number HS 6 1974 The address of the NFPA is 470 Atlantic Avenue Boston MA 02210 24 For further information refer to NFPA 211 25 Do not over fire your woodstove Although the Briarwood II is designed to heat efficiently it should never be fired to a red hot condition 26 CHIMNEY CONNECTOR ...

Страница 11: ...closed container of ashes should be placed on a non combustible material pending final disposal Once they are cooled they can be disposed of by burial in soil or other suitable methods WET OR GREEN FUEL Wet or green fuel should not be used Wood should be cut into pieces and allowed to air dry for several months before you attempt to burn it After the wood supply is cured dry ensure it is protected...

Страница 12: ...er minimum distances from combustible materials FLOOR PROTECTION Floor protection may be any non combustible material or Listed Floor Protector In the USA It must extend at least 18 in front of the loading door opening and 8 inches beyond the sides of the door opening In Canada 18 in front and 8 inches beyond the side and inline with the rear of the stove In certain installations floor protection ...

Страница 13: ...e on your stove 3 If you are installing a new chimney follow the manufacturer s installation instructions very carefully Be sure to comply with all safety recommendations Use only insulated pipe and components with approved shields to pass through combustible walls and ceilings 4 Make a mark on the floor around each corner of the heater Move the stove and install the floor protector Be sure to ext...

Страница 14: ...ney installations Listed solid fuel chimney liners are required for masonry installations in Canada Mobile home units require certain listed components and chimney manufacturers See Mobile Home Instructions page 16 for details Refer to the chimney and chimney connector manufacturer s instructions for additional information If this stove and its chimney components are not properly installed a house...

Страница 15: ...eed three feet NOTE THE CONNECTOR MUST SLOPE UPWARD TOWARD THE CHIMNEY AT THE RATE OF 1 4 PER FOOT This slope in the horizontal connection is required to encourage the water vapor to drain back into the stove Use a carpenter s level and a ruler or tape measure to check the slope Under no condition should the chimney connector have more than one 90 degree bend or two 45 degree bends The distance be...

Страница 16: ... of the stove Always use a star lock washer to ensure a good electrical connection between the ground wire and the stove CHIMNEY HEIGHT The chimney system must have a section joint so that any parts extending over 13 feet 6 inches above ground level can be removed when transporting the mobile structure Care must be taken when dissembling so no hidden joints are loosened to allow flue emissions to ...

Страница 17: ...d 6 You may now place several larger pieces of wood on the fire In order to insure complete combustion of the organic compounds released from the wood load the fuel as far back in the firebox as possible The charcoal bed can be sloped slightly towards the rear so that the fuel does not tend to fall forward Close the door with the draft control open until a robust fire occurs 7 Clean away any coals...

Страница 18: ...n the stove top B Attach the rear heat shield through the shield and into the back of the stove with 4 bolts C Position the fan kit on the rear heat shield The mounting holes are pre punched and located near the bottom Attach using four 10 sheet metal screws USE CARE WHEN ROUTING THE POWER CORD MAKE SURE IT IS NOT UNDERNEATH THE BASE OF THE STOVE Fan Kit Electrical Diagram Rheostat Green Ground Sc...

Отзывы: