Exclusions and Limitations: 

1. This Warranty does not cover tarnish, discoloration or wear on the plated surfaces   Painted finishes will change 

colour after initial firing and will continue to change through the lifetime of the stove. This is normal occurrence for 

all high temperature coatings. 
2. This Warranty does not cover gasket material or firebrick. 

3. Blaze King strongly recommends installation by a certified installer. Failure to comply may adversely affect 

coverage under the terms of this warranty. This Limited Warranty covers defects in materials and workmanship only 

if the product has been installed in accordance with local building and fire codes; in their absence refer to the 

owner’s manual. If the product is damaged or broken as a result of any alteration, wilful abuse, mishandling, 

accident, neglect, or misuse of the product, the Limited Warranty does not apply. 

4. The stove must be operated and maintained at all times in accordance with the instructions in the Owner’s 
Manual. If the unit shows signs of neglect or misuse, it is not covered under the terms of this Warranty policy. 

Performance problems due to operator error will not be covered by the Limited Warranty policy. 

5. Some minor expansion, contraction, or movement of certain parts and resulting noise, is normal and not a defect 

and, therefore, is not covered under this Limited Warranty. 

6. Misuse includes over-firing. Over-firing can be identified later by warped plates and paint pigment being burnt off. 

Over-firing this appliance can cause serious damage and will nullify the Limited Warranty. 
7. The Limited Warranty will cover glass thermal breakage only and will not cover misuse of the stove glass, 

including but not limited to: 

a) Glass that is struck, has surface contaminates or has had harsh or abrasive cleaners used on it. 

b) If the door is slammed or is closed while wood in the firebox is protruding out the stove opening thus striking the 

glass. 

8. This warranty does not cover products made or provided by other manufacturers and used in conjunction with the 

operation of this stove without prior authorization from Blaze King The use of such products may nullify the Limited 
Warranty on this stove. If unsure as to the extent of this Limited Warranty, contact your authorized Blaze King 

dealer before installation. 

9. Blaze King will not be responsible for inadequate performance caused by environmental

 

conditions. 

10. The Limited Warranty does not cover installation and operational related problems such as use of downdrafts or 

spillage caused by environmental conditions. Environmental conditions include but are not limited to nearby trees, 

buildings, roof tops, wind, hills, mountains, inadequate venting or ventilation, excessive offsets, negative air 

pressures or other influences caused by mechanical systems such as furnaces, fans, clothes dryers etc. 
11. The Limited Warranty does not cover damage caused by burning salt-saturated wood, corrosive driftwood, 

chemically treated wood or any fuel not recommended in the Owner’s Manual (use cord wood only). 

The Limited Warranty is void if: 

a) The stove has been operated in atmospheres contaminated by chlorine, fluorine or other damaging chemicals. 

b) The stove is subject to submersion in water or prolonged periods of dampness or condensation. 

c) Any damage to the unit, combustion chamber or other components due to water, or weather damage which is the 
result of, but not limited to, improper chimney/venting installation. 

d) Salt air in coastal areas or high humidity can be corrosive to the finish; these environmental conditions can cause 

rusting. Damage caused by salt air or high humidity is not covered by the Limited Warranty. 

12. Exclusions to the Limited Warranty include: injury, loss of use, damage, failure to function due to accident, 

negligence, misuse, improper installation, alteration or adjustment of the manufacturer’s settings of components, 

lack of proper and regular maintenance, alteration, or act of God. 

13. The Limited Warranty does not cover damage caused to the stove while in transit. If this occurs, do not operate 
the stove and contact your courier and/or dealer. 

14. The Limited Warranty does not extend to or include paint, door or glass gaskets or firebricks damage caused by 

normal wear and tear, such as paint discoloration or chipping, worn or torn gaskets, chipped or cracked firebrick, etc. 

15. The Limited Warranty does not include damage to the unit caused by abuse, improper installation, or 

modification of the unit. 

16. Damage to plated surfaces caused by fingerprints, scratches, melted items, or other external scores and residues 

left on the plated surfaces from the use of abrasive cleaners or polishes is not covered in this warranty. 
17. Blaze King is free of liability for any damages caused by the stove, as well as inconvenience expenses and 

materials. The Limited Warranty does not cover incidental or consequential damages. 

18. The Limited Warranty does not cover any loss or damage incurred by the use or removal of any component or 

apparatus to or from the Blaze King stove without the express written permission of Blaze King and bearing a Blaze 

King label of approval. 

19. Any statement or representation of Blaze King Products and their performance contained in Blaze King 
advertising, packaging literature, or printed material is not part of the Limited Warranty. 

 

Warranty cont. 

Содержание BRIARWOD BRII/90

Страница 1: ...THESE INSTRUCTIONS FOR FUTURE REFERENCE LISTED BY Valley Comfort Systems Inc 1290 Commercial Way Penticton BC V2A 3H5 CANADA Phone 250 493 7444 Fax 250 493 5833 Blaze King Industries 146 A Street Walla Walla WA 99362 U S A Phone 509 522 2730 Fax 509 522 9803 Manufactured By Blaze King Pour la version française de nos manuels S V P vous référez à notre site web www blazeking com ...

Страница 2: ...by a qualified licensed installer have it checked by your local inspector Disregarding inspection and code requirements may jeopardize your homeowner s insurance Since some insurance carriers require notification of a stove installation you should contact your insurance agent We want your stove to give you many years of trouble free operation While we have made every effort to make these instructi...

Страница 3: ...imney Draft 14 Chimney height 14 Chimney requirements 14 Chimney Installation Masonry Chimney 15 Mobile Home Installation Instructions 16 Grounding 16 Chimney Height 16 Outside Air 16 Floor Protection 16 Attaching Stove to Floor 16 Operation 17 Grates 17 First Fire 17 Curing Paint 17 Starting Fire 17 Controls 17 Do Not Burn 17 Heat Output 17 Do Not Over fire 17 Accessories Installation Fan Kit and...

Страница 4: ...owner End User except as noted for replacement parts Warranty Period Components Covered Parts Labor Wood 1 Year X All parts materials and surface finishes flaking and peeling Subject to Conditions Exclusion and Limitations listed 2 Years X Fan assemblies and motors thermal sen sors catalytic thermometer bi metallic thermostat assembly 5 Years 2 Year X Firebox Heat Exchanger Bypass Door Steel Compo...

Страница 5: ...aser Please see the exclusions and limitation section below as certain restrictions and exclusions apply to this warranty How the Warranty Works 1 All warranties by the manufacturer are set herein and no claim shall be made against the manufacturer on any oral warranty or representation All claims under this Limited Warranty must be made in writing by your dealer 2 Any stove or part thereof that i...

Страница 6: ...environmental conditions Environmental conditions include but are not limited to nearby trees buildings roof tops wind hills mountains inadequate venting or ventilation excessive offsets negative air pressures or other influences caused by mechanical systems such as furnaces fans clothes dryers etc 11 The Limited Warranty does not cover damage caused by burning salt saturated wood corrosive driftw...

Страница 7: ...King to be non warrantable Blaze King is not liable for travel costs for service work In the event of in home repair work the customer will pay any in home travel fees or service charges required by the Authorized Dealer 26 At no time will Blaze King be liable for any consequential damages which exceed the purchase price of the unit Blaze King has no obligation to enhance or modify any stove once ...

Страница 8: ...TIBLES See owners manual for complete description of all requirements Mobile Home and Alcove Installations must use double wall listed pipe side shields and rear shield Mobile Home Installations require Outside Combustion Air Kit Z1526 Floor protection may be any non combustible material or Listed Floor Protector and must extend at least 18 406 mm in front of the loading door opening Minimum size ...

Страница 9: ...ST HOME FIRES CAUSED BY WOODBURNING STOVES ARE THE RESULT OF IMPROPER INSTALLATION AND OPERATION READ ALL INSTRUCTIONS THOROUGHLY BEFORE INSTALLING AND OPERATING YOUR Briarwood II STOVE SAVE THESE INSTRUCTIONS SAFETY PRECAUTIONS 1 CONSULT YOUR LOCAL BUILDING INSPECTOR TO ENSURE YOUR INSTALLATION COMPLIES WITH BUILDING AND FIRE CODES 2 Design your installation with safety as the primary considerati...

Страница 10: ...ely obtain a copy of the National Fire Protection Association publication Using Coal and Wood stoves Safely NFPA Number HS 6 1974 The address of the NFPA is 470 Atlantic Avenue Boston MA 02210 24 For further information refer to NFPA 211 25 Do not over fire your woodstove Although the Briarwood II is designed to heat efficiently it should never be fired to a red hot condition 26 CHIMNEY CONNECTOR ...

Страница 11: ...closed container of ashes should be placed on a non combustible material pending final disposal Once they are cooled they can be disposed of by burial in soil or other suitable methods WET OR GREEN FUEL Wet or green fuel should not be used Wood should be cut into pieces and allowed to air dry for several months before you attempt to burn it After the wood supply is cured dry ensure it is protected...

Страница 12: ...er minimum distances from combustible materials FLOOR PROTECTION Floor protection may be any non combustible material or Listed Floor Protector In the USA It must extend at least 18 in front of the loading door opening and 8 inches beyond the sides of the door opening In Canada 18 in front and 8 inches beyond the side and inline with the rear of the stove In certain installations floor protection ...

Страница 13: ...e on your stove 3 If you are installing a new chimney follow the manufacturer s installation instructions very carefully Be sure to comply with all safety recommendations Use only insulated pipe and components with approved shields to pass through combustible walls and ceilings 4 Make a mark on the floor around each corner of the heater Move the stove and install the floor protector Be sure to ext...

Страница 14: ...ney installations Listed solid fuel chimney liners are required for masonry installations in Canada Mobile home units require certain listed components and chimney manufacturers See Mobile Home Instructions page 16 for details Refer to the chimney and chimney connector manufacturer s instructions for additional information If this stove and its chimney components are not properly installed a house...

Страница 15: ...eed three feet NOTE THE CONNECTOR MUST SLOPE UPWARD TOWARD THE CHIMNEY AT THE RATE OF 1 4 PER FOOT This slope in the horizontal connection is required to encourage the water vapor to drain back into the stove Use a carpenter s level and a ruler or tape measure to check the slope Under no condition should the chimney connector have more than one 90 degree bend or two 45 degree bends The distance be...

Страница 16: ... of the stove Always use a star lock washer to ensure a good electrical connection between the ground wire and the stove CHIMNEY HEIGHT The chimney system must have a section joint so that any parts extending over 13 feet 6 inches above ground level can be removed when transporting the mobile structure Care must be taken when dissembling so no hidden joints are loosened to allow flue emissions to ...

Страница 17: ...d 6 You may now place several larger pieces of wood on the fire In order to insure complete combustion of the organic compounds released from the wood load the fuel as far back in the firebox as possible The charcoal bed can be sloped slightly towards the rear so that the fuel does not tend to fall forward Close the door with the draft control open until a robust fire occurs 7 Clean away any coals...

Страница 18: ...n the stove top B Attach the rear heat shield through the shield and into the back of the stove with 4 bolts C Position the fan kit on the rear heat shield The mounting holes are pre punched and located near the bottom Attach using four 10 sheet metal screws USE CARE WHEN ROUTING THE POWER CORD MAKE SURE IT IS NOT UNDERNEATH THE BASE OF THE STOVE Fan Kit Electrical Diagram Rheostat Green Ground Sc...

Отзывы: