OM-SC30.1 E V1.01
January 20, 2015
Page 17
SC30
.1
INSTALLATION INSTRUCTIONS cont.
MOBILE HOME (AND RESIDENTIAL ALCOVE INSTALLATIONS)
Either Rear Shield OR Fan kit are required for these installations (See next page for kits and part numbers).
Mobile home installations also requires the Outside Air Kit: Z1726B. Th
ey are easiest to mount before the stove
is installed. See instructions packed with each kit.
When a metal prefabricated chimney is used, the manufacturer’s installation instructions must be followed
precisely. You must also purchase (from the same manufacturer) and install the ceiling support package, fi re
stops (when needed), insulation shield, roof fl ashing, chimney cap, etc. Maintain the proper clearance to the
structure as recommended by the manufacturer.
Chimney connector must be double wall close clearance type with either ULC629 or ULCS610 designation.
Single wall pipe is not allowed in Mobile Homes or in Alcove Installations. Insulated chimney components
must be a listed factory built chimney suitable for use with solid fuels and conforming to, ULC629 in Canada or
UL-103HT in the USA. For Mobile home, the chimney need to be removable to allow for transportation of the
mobile home.
DO NOT INSTALL IN SLEEPING ROOM. THE STRUCTURAL INTEGRITY OF THE MOBILE
HOME FLOOR, WALL AND CEILING / ROOF MUST BE MAINTAINED.
In mobile home installations, the stove must be securely fastened to the fl oor using the tie-downs provided
in the Outside Air kit.
(For the pedestal model, remove the ash drawer to access the screw down holes. For the
Leg model, use the Leg Anchor Kit (P/N ZR8039) to secure stove to fl oor.)
ALSO, a #8 ground wire must be attached to the stove and an appropriate ground.