INSTALLATION INSTRUCTIONS cont.
MINIMUM CLEARANCES for SC30
.1
G = 3 3/4” (96mm) in USA
8” (203mm) in Canada
H = 16” (406mm) in USA
18” (456mm) in Canada
I = 0” (0mm) in USA
8” (203mm) in Canada
K = 18” (456mm) for single wall pipe in Canada
Ember protection shield (not required to have an insulation value) or
a listed UL 1618 Type 1 fl oor protector must have a minimum size of:
In USA: 35” x 42 1/8” (889 mm x 1070 mm)
In Canada: 43 1/2” x 52 1/8”(1105 mm x 1324 mm)
Min. Alcove minimum width 49”, maximum depth 48”, minimum height above stove top 37”.
This stove must be installed in compliance with all local codes and regulations.
*1
*1
F
E
G
I
H
K
J
C
A
G
G
D
I
2"(51 mm)
H
B
" in USA
4
*1= 4
3
4
" in Canada and 2
1
8
" in USA
*2 = 59
1
4
" in Canada and 57
1
*2
*3ft recomended
MIN.2ft*
Residential Installations
A
B
C
D
E
F
J
Roof exit, parallel and corner.
10.75”
273 mm
6”
153 mm
24.5”
623 mm
16.375”*
416 mm
4”
102 mm
18”*
458 mm
37”
940 mm
Wall exit, parallel and corner.
10.75”
273 mm
6”
153 mm
24.5”
623 mm
16.375”*
416 mm
4”
102 mm
18”*
458 mm
37”*
940 mm
Alcove, roof exit. Fan kit or rear shield required.
10.75”
273 mm
6”
153 mm
24.5”
623 mm
16.375”*
416 mm
37”
940 mm
Mobile Home Installation
Roof exit, parallel and corner. Fan kit or rear shield required. Outside air kit
required.
10.75”
273 mm
6”
153 mm
24.5”
623 mm
16.375”*
416 mm
4”
102 mm
18”*
458 mm
37”
940 mm
* Check with local codes and pipe manufacturer for pipe clearances. In Canada, 18” clearances from single wall pipe is required.
Clearances may only be reduced by means approved by the regulatory authority