VENTO Solar V60 Pro

HEAT RECOVERY SINGLE-ROOM 

VENTILATION UNIT 

OPERATION MANUAL

EN

VENTO_Solar_V60_Pro_v.1(2)_EN.indd   1

07.08.2015   12:06:35

Содержание VENTO Solar V60 Pro

Страница 1: ...VENTO Solar V60 Pro HEAT RECOVERY SINGLE ROOM VENTILATION UNIT OPERATION MANUAL EN VENTO_Solar_V60_Pro_v 1 2 _EN indd 1 07 08 2015 12 06 35 ...

Страница 2: ...acturer s warranty 3 Design and operating logic 4 Modifications and options 5 Delivery set 5 Technical data 6 Mounting 7 Connection to power mains and control 10 Maintenance 15 Troubleshooting and fault handling 16 Acceptance certificate 17 Connection certificate 17 Warranty card 17 VENTO_Solar_V60_Pro_v 1 2 _EN indd 2 07 08 2015 12 06 36 ...

Страница 3: ...als The unit is not designed for use in an inflammable and explosive medium Do not close or block the unit intake or exhaust vent not to disturb the normal air passage Do not sit on the unit and do not put objects on the unit In case of unusual sounds smoke disconnect the unit from power supply and contact the service centre Follow the operation manual guidelines to ensure trouble free operation a...

Страница 4: ...nd extracted with an axial reversible EC fan with low energy demand The motor has overheating protection and ball bearings for a longer service life Two built in filters with total filter class G3 are used for supply and extract air filtration and prevent contamination of the energy regenerator The outer ventilation hood must be installed on outer side of the building to prevent ingress of large o...

Страница 5: ...port damages while accepting the goods Check the ordered and the delivered goods for compliance Fig 2 VENTO Solar V60 Pro Fig 4 VENTO Solar V60 S Pro Fig 3 VENTO Solar V60 Pro2 Fig 5 VENTO Solar V60 S Pro2 The unit has four ventilation modes 1 Ventilation mode air supply or air extract at first speed 2 Ventilation mode air supply or air extract at second speed 3 Reversible mode regeneration at fir...

Страница 6: ...ed air temperature C 20 up to 50 Total filter class 2 filters G3 Replacement filter set FP VENTO Solar V60 G3 separate order Heat recovery efficiency up to 88 Heat exchanger type Ceramic energy regenerator Ingress protection rating IP24 Parameters Solar panel Voltage V 18 Current A 1 12 Power W 20 Parameters Storage battery Voltage V 12 Charge storage capacity Ah 3 5 Parameters Charger Voltage V 1...

Страница 7: ...stall the telescopic air duct in the wall The protruding telescopic air duct section on outer wall side must be equal to the distance A max A Inside Outside Model A mm VENTO Solar V60 Pro Pro2 10 VENTO Solar V60 S Pro S Pro2 10 110 3 Fix the inner part of the telescope on inner wall using the screws 3x25 from the delivery set 4 Fill the gaps between the wall and the telescopic air duct with a moun...

Страница 8: ...2 models Disassemble the front part of the outer ventilation hood Abb 8b for the VENTO Solar V60 S Pro S Pro2 models Remove the 5 screws and take off the front part of the outer ventilation hood 12 Attach the back part of the ventilation hood to the wall Fig 9a for the VENTO Solar V60 Pro Pro2 models Attach the back part of the ventilation hood to the wall using the screws 4x40 from the delivery s...

Страница 9: ...ot place the solar panel in shadows 30 45 Horizon line 60 45 17 Install SEV T12 power and control unit in a prepared hole in the wall as shown below The installation place must be selected with respect to the supplied cable length A longer cable may be used on a customer request The cable type is LIYY UL CSA 5xAWG 7 5x0 25 А А 70 mm 48 mm 70 mm R35 SEA Т12 А А 18 Uplift gently the buttons and the ...

Страница 10: ...ic norms and standards The unit must be connected to a correct mounted socket with a grounded terminal or connected to a fixed installed cable Follow the respective electric standards safety rules DIN VDE 0100 TAB der EVUs The house cabling system must be equipped with an automatic switch at the external input Connect the unit to power mains through the automatic switch The contact gap on all pole...

Страница 11: ...wer supply to the ventilation unit 12 V VENTO SOLARV60 PRO2 VENTO SOLARV60 S PRO2 operation modes In the day time or when the storage battery is charged the unit is powered by the accumulated in the storage battery solar energy 230 V SEV T12 Solar panel Switching unit Control signal Power supply to the ventilation unit 12 V In the night time in low light conditions or when the storage battery is d...

Страница 12: ...nd control unit 1 2 3 4 5 31 32 33 34 35 36 XT1 XT2 XT4 L3 L2 L1 3 2 1 P1 P2 P3 XT3 P4 11 12 13 14 15 11 12 13 14 15 1 2 3 4 5 SEV T12 power and control unit Power input 230 V 50 Hz 120 V 60 Hz 120 V or 230 V red red white white 12 V Fig 13 External wiring diagram for VENTO Solar V60 Pro VENTO Solar V60 S Pro VENTO_Solar_V60_Pro_v 1 2 _EN indd 12 07 08 2015 12 06 48 ...

Страница 13: ...control unit 2 1 Storage battery 1 2 3 4 5 31 32 33 34 35 36 XT1 XT2 XT4 L3 L2 L1 3 2 1 P1 P2 P3 XT3 P4 11 12 13 14 15 11 12 13 14 15 1 2 3 4 5 SEV T12 power and control unit Power input 230 V 50 Hz 120 V 60 Hz 120 V or 230 V red red white white 12 V Fig 14 External wiring diagram for VENTO Solar V60 Pro2 VENTO Solar V60 S Pro2 VENTO_Solar_V60_Pro_v 1 2 _EN indd 13 07 08 2015 12 06 49 ...

Страница 14: ...onnection of several units A single power and control unit SEV T12 is able to operate unlimited number of VENTO Solar V60 units under condition that each ventilation unit is connected to an individual solar panel or to an individual storage battery The connecting cables K1 K2 Kn 3x0 25 3xAWG 24 are not included in the delivey set To provide balanced ventilation set one half of the ventilators to t...

Страница 15: ...sh those under running water or use a vacuum cleaner Fig 18 Let the filters dry and install the dry filters inside the air duct Contact a local distributor for the filters stated above in the section Technical data Even regular filter maintenance may not completely prevent dust in gress into the heat regenerator Clean the heat regenerator with a vacu um cleaner at least once a year to keep ist hig...

Страница 16: ...fan or the energy regenerator are soiled Clean or replace the filter Clean the fan and the energy regenerator Refer to the maintenance procedure of the energy regenerator and the filters Noise vibration The impeller is soiled Clean the impeller Loose screw connection of the unit casing or the outer ventilation hood Tighten the screws of the unit or the outer ventilation hood TROUBLESHOOTING 4 Sola...

Страница 17: ... compatibility This certificate is issued following test carried out on samples of the product referred to above Approval mark Manufacturing date ____________________ Company Name Date Signature The single room reversible heat recovery ventilation unit VENTO Solar V60 Pro VENTO Solar V60 Pro2 VENTO Solar V60 S Pro VENTO Solar V60 S Pro2 is connected to power mains in compliance with the operation ...

Страница 18: ...______ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _________________________________________...

Страница 19: ...______ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _________________________________________...

Страница 20: ...www blaubergventilatoren de VENTO Solar V60 Pro v 1 2 EN VENTO_Solar_V60_Pro_v 1 2 _EN indd 20 07 08 2015 12 06 52 ...

Отзывы: