Fan runs at speed 1

Switch contact S1 is CLOSED

Activation of turn-on 

delay timer (0-2 minutes)

Fan runs at speed 2

S1 switch contact is OPENED

Activation of turn-off 

delay timer (2-30 minutes)

Switch contact S1 is OPENED 

during the turn-on 

delay timer operation

No

Yes

Содержание Trio

Страница 1: ...User s manual Trio AXIAL FAN EN ...

Страница 2: ...ting document intended for technical maintenance and operating staff The manual contains information about purpose technical details operating principle design and installation of the Trio unit and all its modifications Technical and maintenance staff must have theoretical and practical training in the field of ventilation systems and should be able to work in accordance with workplace safety rule...

Страница 3: ... requirements as well as the provisions of all the applicable local and national construction electrical and technical norms and standards must be observed when installing and operating the unit Disconnect the unit from the power supply prior to any connection servicing maintenance and repair operations Only qualified electricians with a work permit for electrical units up to 1000V are allowed for...

Страница 4: ...rain sun etc Transported air must not contain any dust or other solid impurities sticky substances or fibrous materials Do not use the unit in a hazardous or explosive environment containing spirits gasoline insecticides etc Do not close or block the intake or extract vents in order to ensure the efficient air flow Do not sit on the unit and do not put objects on it The information in this user s ...

Страница 5: ...d persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Cleaning and user maintenance shall not be made by children without supervision Children shall not play with the appliance Precautions must be taken to avoid the back f...

Страница 6: ...be made through a disconnecting device which is integrated into the fixed wiring system in accordance with the wiring rules for design of electrical units and has a contact separation in all poles that allows for full disconnection under overvoltage category III conditions Ensure that the unit is switched off from the supply mains before removing the guard ...

Страница 7: ...ES The fan is rated for connection to single phase AC power mains Power mains parameters are stated on the unit packaging and or the label on the unit casing Ingress protection rating against access to hazardous parts and water ingress is IP44 WARNING IP is indicated for an assembled unit The fan is rated for operation at ambient temperatures ranging from 1 C to 40 C WARNING Do not operate the fan...

Страница 8: ...draft damper with a membrane of light polymer e2 ball bearing without a backdraft damper K1 ball bearing and a plastic petal backdraft damper e K1 sliding bearing and a plastic petal backdraft damper Additional options S pull cord switch T turn off delay timer TR turn on and turn off delay timer ST turn off delay timer and pull cord switch H humidity sensor and turn off delay timer SH humidity sen...

Страница 9: ...installation vertical air discharge upwards is not allowed even if there is a protective outer hood on the roof For ceiling mounting and air discharge to the roof the duct system must include a condensate drain Fig 3 A condensate drain is not included in the delivery set of the fan and can be ordered separately Check the fan for any visible damages of the impeller the casing and the grille before ...

Страница 10: ... for 12V power voltage stated on the packing box and on the fan casing connect to 12V power mains only WARNING Thepowercablemayonlybelaidthroughtheholeinthecasingprovidedbythemanufacturer Fig 13 Laying the power cable through a manually drilled hole will not be the liability of the manufacturer and will void the warranty The wires must be stripped of insulation by a maximum of 8 mm Fig 13 After in...

Страница 11: ...e value of the turn on delay time is adjustable in the range from 0 to 2 minutes After some turn on delay time has elapsed the fan switches to Speed 2 After disconnecting the control voltage the fan runs for a time set by the turn off delay timer from 2 to 30 minutes and switches to the first speed The fan with the timer and the humidity sensor H the fan starts after the control voltage is supplie...

Страница 12: ...nt adjustable from 2 up to 30 minutes To adjust the humidity set point turn the control knob H clockwise to increase and counter clockwise to decrease the humidity sensor set point adjustable from 60 up to 90 The fan delivery set includes a specially designed plastic screwdriver for fan settings adjustments Use it to change the turn on and turn off delay time and the humidity set point H 60 90 Tof...

Страница 13: ... liquid come into contact with electric components TROUBLESHOOTING Problem Possible reasons Troubleshooting When the unit is connected to power mains the fan does not rotate and does not respond to any controls No power supply Make sure the power supply line is connected correctly otherwise troubleshoot the connection error Internal connection fault Contact the Seller Low air flow The ventilation ...

Страница 14: ...or handling and storage operations to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo The unit can be carried in the original packaging by any mode of transport provided proper protection against precipitation and mechanical damage The unit must be transported only in the working position Avoid sharp blows scratches or rough handling...

Страница 15: ...The warranty repair includes work specific to elimination of faults in the unit operation to ensure its intended use by the user within the guaranteed period of operation The faults are eliminated by means of replacement or repair of the unit components or a specific part of such unit component The warranty repair does not include routine technical maintenance unit installation dismantling unit se...

Страница 16: ...xpiration of the unit warranty period Violation of the unit transportation regulations by the user Violation of the unit storage regulations by the user Wrongful actions against the unit committed by third parties Unit breakdown due to circumstances of insuperable force fire flood earthquake war hostilities of any kind blockades Missing seals if provided by the user s manual Failure to submit the ...

Страница 17: ...17 EN B ø D L 1 D mm B mm L mm Trio100 100 150 102 Trio 150 150 206 123 10 20 2 3 ...

Страница 18: ...18 EN QF L N 4 5 6 7 8 9 10 11 12 ...

Страница 19: ... N L S N QF L N L S1 100 150 100 150 Т 100 150 SТ Fan does not run Contact of S1 switch or pull cord switch is CLOSED Fan runs Contact of S1 switch or pull cord switch is OPENED Activation of turn off delay timer 2 30 minutes 8 mm max ...

Страница 20: ...f S1 switch or pull cord switch is CLOSED Switch is deactivated during countdown of turn on delay timer Fan runs Contact of S1 switch or pull cord switch is OPENED Activation of turn off delay timer 2 30 minutes Yes No Activation of turn on delay timer 0 2 minutes ...

Страница 21: ... not run Humidity exceeds set point No Yes Humidity is below set point Activation of turn off delay timer 2 30 minutes Contact of S1 switch or pull cord switch is CLOSED Fan runs Contact of S1 switch or pull cord switch is OPENED Humidity exceeds set point Yes No Fan runs ...

Страница 22: ...speed 1 Switch contact S1 is CLOSED Activation of turn on delay timer 0 2 minutes Fan runs at speed 2 S1 switch contact is OPENED Activation of turn off delay timer 2 30 minutes Switch contact S1 is OPENED during the turn on delay timer operation No Yes ...

Страница 23: ...int Activation of turn off delay timer for 5 minutes Switch contact S1 is CLOSED Activation of turn on delay timer 45 seconds Switch contact S1 is OPENED during the turn on delay timer operation Yes No Fan runs at speed 2 S1 switch contact is OPENED Humidity exceeds set point No Yes Activation of turn off delay timer 2 30 minutes 17 ...

Страница 24: ...24 EN 18 S N QF L N L S1 V2 100 150 S1 switch is in L position Fan runs at speed 2 Fan runs at speed 1 Yes No ...

Страница 25: ...25 EN QF L N 19 20 21 22 ...

Страница 26: ...26 EN ...

Страница 27: ...27 EN Quality Inspector s Stamp Manufacture Date Sold by name and stamp of the seller Purchase Date ...

Страница 28: ...www blaubergventilatoren de B216EN 03 Trio V2 S T 100 TR 12 150 ST 220 V 60 Hz H SH ...

Отзывы: