Store the unit in the manufacturer’s original packing box in a dry closed ventilated premise with temperature range from +5 ˚C to + 40 ˚C. Vapours or 
particles which can cause corrosion or damage the insulation or connection tightness are not allowed in the storage environment. 
Use hoist machinery for handling and transportation to prevent possible mechanical damages of the unit. 
Use any vehicle types for the unit transportation provided that it is protected against mechanical or weather damage. 
Fulfil the requirements for transportation of the specified cargo type. 
Avoid any mechanical shocks and strokes during handling operations.
Do not expose the product to rapid temperature changes. A rapid change of temperature may result in generation of the condensate inside the unit 
and lead to malfunction of the unit. 
After transportation or storage of the unit at low temperatures its connection to power mains is allowed only after the unit is kept at least for 2 hours at 
operation temperature conditions. 

The warranty period is 24 months after the retail sale date provided the user’s observance of the transportation, storage, mounting and operation 
regulations. 
Should any malfunctions occur in the course of the unit operation through the Manufacturer’s fault during the guaranteed period of operation the user 
is entitled to elimination of faults by the manufacturer by means of warranty repair at the factory free of charge.
The warranty repair shall include work specific to elimination of faults in the unit operation to ensure its intended use by the user within the guaranteed 
period of operation.
The faults are eliminated by means of replacement or repair of the unit components or a specific part of such unit component.

The warranty repair does not include: 

• 

Routine technical maintenance;

• 

Unit installation / dismantling; 

• 

Unit setup. 

To benefit from warranty repair the user must provide the unit, the user’s manual with the purchase date stamp and the payment document certifying 
the purchase. 
The unit model must comply with the one stated in the user’s manual. 
Contact the Seller for warranty service. 

The manufacturer’s warranty does not apply to the following cases: 

• 

User’s failure to submit the unit with the entire delivery package as stated in the user’s manual including submission with missing component 
parts previously dismounted by the user.

• 

Mismatch of the unit model and the brand name with the information stated on the unit packing and in the user’s manual.

• 

User’s failure to ensure timely technical maintenance of the unit.

• 

External damage to the unit casing (excluding external modifications as required for installation) and internal components caused by the user.

• 

Redesign or engineering changes to the unit.

• 

Replacement and use of any assemblies, parts and components not approved by the manufacturer.

• 

Unit misuse.

• 

User’s violation of the unit installation regulations.

• 

User’s violation of the unit control regulations.

• 

Unit connection to the power mains with a voltage different from the one stated in the user’s manual.

• 

Unit breakdown due to voltage surges in the power mains.

• 

Discretionary repair of the unit by the user.

• 

Unit repair by any persons without the manufacturer’s authorization.

• 

Expiration of the unit warranty period.

• 

User’s violation of the unit transportation regulations.

• 

User’s violation of the unit storage regulations.

• 

Wrongful actions against the unit committed by third parties.

• 

Unit breakdown due to circumstances of insuperable force (fire, flood, earthquake, war, hostilities of any kind, blockades).

• 

Missing seals if provided by the user’s manual.

• 

Failure to submit the user’s manual with the unit purchase date stamp.

• 

Missing payment document certifying the unit purchase. 

STORAGE AND TRANSPORTATION REGULATIONS

MANUFACTURER’S WARRANTY

Содержание Komfort ERV EC DB 150 S14

Страница 1: ...OPERATION MANUAL Komfort ERV EC DB 150 S14 Komfort ERV EC DB 250 S14 Komfort ERV EC DB 350 S14 AIR HANDLING UNIT WITH HEAT AND HUMIDITY RECOVERY EN ...

Страница 2: ... the unit as mentioned in the Safety Requirements and Manufacturer s Warranty sections as well as in warnings and information blocks Read the user s manual carefully prior to installing and operating the unit Fulfil the user s manual requirements as well as the provisions of all the applicable local and national construction electrical and technical norms and standards The warnings contained in th...

Страница 3: ...wet hands Do not wash the unit with water Protect the electric parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains prior to any technical maintenance Do not store any explosive or highly flammable substances in close proximity to the unit When the unit generates unusual sounds odour or emits smoke disconnect it from power supply...

Страница 4: ...AND CONNECTED ONLY BY PROPERLY QUALIFIED PERSONNEL AFTER THE APPROPRIATE BRIEFING THE CHOICE OF UNIT INSTALLATION PLACE MUST PREVENT UNAUTHORIZED ACCESS BY UNATTENDED CHILDREN Transported air must not contain any flammable or explosive mixtures evaporation of chemicals sticky substances fibrous materials coarse dust soot and oil particles or environments favourable for the formation of hazardous s...

Страница 5: ...14 Komfort ERV EC DB 250 S14 Komfort ERV EC DB 350 S14 Supply Voltage 50 60 Hz V 1 230 Max power consumption W 70 84 150 Max current consumption A 0 6 0 7 1 0 Air capacity m3 h CFM 180 300 400 RPM min 1 1925 2000 3200 Noise level 3 m dB A 32 36 46 Transported air temperature C from 25 up to 40 Casing material Painted steel Insulation 5 mm 10 mm foam rubber Extract filter G4 Supply filter G4 and F8...

Страница 6: ... 947 854 676 704 743 793 227 247 480 92 128 25 113 88 Komfort ERV EC DB 350 S14 149 1117 1024 846 754 793 843 277 297 488 109 153 50 88 138 R1 5 OUT OUT OUT IN Rx Tx 86 58 39 21 11 2 86 4 62 3 52 Control panel The touch control buttons and the alarm indicator are located on the sensor control panel Power supply voltage 8 30 V Temperature range from 0 C up to 45 C Service life 100 000 switching ope...

Страница 7: ...e and the grounding cable are connected to the control unit through the electric lead ins on the unit side wall The plate enthalpy cross flow heat exchanger is made of polymerized cellulose The bypass damper is in open or closed position depending on the unit operation mode Upon customer s demand the unit may be equipped with a humidity sensor available as an accessory The unit with the installed ...

Страница 8: ...it up and humidifies The moisture vapour condensate generated by humid laden extract air is absorbed by the heat exchanger plates The humidity and heat energy are transferred to the supply air and the microbes and odours are separated EXTRACT AIR SUPPLY AIR INTAKE AIR EXHAUST AIR Defrosting mode the defrosting mode is designed for heat exchanger freezing protection and is activated on feedback fro...

Страница 9: ...rdered accessories While selecting fastener type consider the mounting surface material and the ventilation unit weight For details please refer to the technical data of the unit The fasteners must be selected by a professional Prior to the installation check the unit casing for any left over foreign objects such as plastic film or paper While mounting the unit make sure to provide sufficient serv...

Страница 10: ...e the required wires and cables to the control panel installation place Install the mounting box for wall flush mounting The mounting box is included in the delivery set 2 Use a screwdriver to carefully undo the latches on the backside of the control panel and remove the back cover 3 Screw the back side of the casing to the mounting box through the mounting holes The screws for connection of the c...

Страница 11: ...TING PLATE ANY TAMPERING WITH THE INTERNAL CONNECTIONS IS PROHIBITED AND WILL VOID THE WARRANTY DO NOT LAY THE CABLE IN CLOSE PROXIMITY TO THE CONTROL PANEL CABLE DO NOT COIL THE CABLE FROM THE CONTROL PANEL IN LOOPS WHILE LAYING IT The unit is rated for connection to single phase ac 230 V 50 60 Hz power mains The cable connecting the control panel and the air handling unit must match the criteria...

Страница 12: ...ed into delivery set available as a special order to the contact socket in accordance with the external wiring diagram Connection of the external air dampers SM1 supply air damper SM2 exhaust air damper The air dampers and the electric actuator are not included in the delivery set available as specially ordered accessories For connection of the air dampers use an electric actuator of LF 230 BELIMO...

Страница 13: ...l panel is send to the control unit and the unit starts operation with a set operation mode The control panel is not designed for standalone operation WARNING Fix the control panel in the operating position prior to using it Do not press the touch buttons when the control panel is not fixed to avoid false speed activation Quick short pressing of the touch buttons may result in the unit malfunction...

Страница 14: ...PRIORTO ANY MAINTENANCE OPERATIONS THECONTROLUNITMAINTENANCEMUSTBEPERFORMEDBYANEXPERTQUALIFIEDFORUNASSISTED OPERATIONS WITH ELECTRICAL INSTALLATIONS WITH THE VOLTAGE UP TO 1000 V AFTER CAREFUL READING OFTHE USER S MANUAL Maintenance operations of the unit are required 3 4 times per year Maintenance includes regular cleaning and the following operations 1 Filter maintenance 3 4 times per year Conta...

Страница 15: ...t Problem Possible reasons Troubleshooting The fan s do es not get started No power supply Make sure the power supply line is connected correctly otherwise troubleshoot a connection error Low air flow Filters fans or the heat exchanger are contaminated Clean or replace the filters clean the fan s and the heat exchanger The ventilation system is contaminated or damaged Clean the ventilation system ...

Страница 16: ... not include Routine technical maintenance Unit installation dismantling Unit setup To benefit from warranty repair the user must provide the unit the user s manual with the purchase date stamp and the payment document certifying the purchase The unit model must comply with the one stated in the user s manual Contact the Seller for warranty service The manufacturer s warranty does not apply to the...

Страница 17: ...irective 2006 95 EC 73 23 EEC and CE marking Directive 93 68 EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility This certificate is issued following test carried out on samples of the product referred to above Approval mark Manufacturing date ____________________ Company Name Date Signature Air handling unit with heat and humidity recovery Komfort E...

Страница 18: ...18 www blaubergventilatoren de Komfort ERV EC DB S14 ...

Страница 19: ...www blaubergventilatoren de 19 Komfort ERV EC DB S14 ...

Страница 20: ...www blaubergventilatoren de Komfort ERV EC DB S14 ...

Отзывы: