CONNECTION TO POWER MAINS 

DISCONNECT THE UNIT FROM POWER MAINS PRIOR TO ANY OPERATIONS. 

THE UNIT MUST BE CONNECTED TO POWER MAINS BY A QUALIFIED ELECTRICIAN. 

THE RATED ELECTRICAL PARAMETERS OF THE UNIT ARE SHOWN ON THE RATING PLATE.

ANY TAMPERING WITH THE INTERNAL CONNECTIONS IS PROHIBITED AND WILL VOID

THE WARRANTY.

The fan is rated for connection to single-phase AC 120 V/ 50/ (60) Hz power supply.
The fan must be connected to power mains using durable, insulated and heat-resistant conductors (cables and wires) via the circuit
breaker QF integrated into the house cabling system.
The external circuit breaker installation place must ensure unhampered access for emergency shutdown of the unit

WIRING DIAGRAMS

L2
L1
N

L

N

LT

N

L

N

L

QF

LIGHT

(contact socket is available only for 
the models with LED light)

FAN

Х1

QF

1

2

3

4

5

6

7

120 V
60 Hz

120 V
60 Hz

ACCESS TO THE TERMINAL BOX FOR WIRING THE FAN

Remove the decorative grille. 
For accessing the connection terminals 
loosen the screw on the terminal box 
lid and take the lid off. 

Remove the protective cap and install the cable gland. 

www.blauberg.us

MIU_76_77-01

174 N. 36th Street, Lafayette, IN 47905
e-mail: [email protected]

Содержание CEILEO 110

Страница 1: ...er joist with the distance between the ceiling joists from 270 mm 10 5 8 up to 680 mm 20 3 4 using the removable fixing brackets or the fastening holes in the fan casing The installation place must be in compliance with local construction norms for units of this type Check the fan for mechanical damages prior to mounting Make sure that the casing comprises no foreign objects such as paper or foil ...

Страница 2: ...from the grille prior to its installation Route the contact socket of the sensorTH orTP via the opening in the grille and connect the sensor socket to the respective contact socket on the control unit Fix the sensor in the grille opening and cover the opening with a protective cap Connection socket of the humidity sensor Connection socket of the motion sensor Connection socket of the LED lamp Conn...

Страница 3: ...ing joists Fixation between the ceiling joists using the mounting brackets Additional fastening holes in the fan casing may be used for mounting purposes BASIC FAN INSTALLATION OPTIONS www blauberg us MIU_76_77 01 174 N 36th Street Lafayette IN 47905 e mail info blauberg us ...

Страница 4: ...tors cables and wires via the circuit breaker QF integrated into the house cabling system The external circuit breaker installation place must ensure unhampered access for emergency shutdown of the unit WIRING DIAGRAMS L2 L1 N L N LT N L N L QF LIGHT contact socket is available only for the models with LED light FAN Х1 QF 1 2 3 4 5 6 7 120V 60 Hz 120V 60 Hz ACCESSTOTHETERMINAL BOX FORWIRINGTHE FAN...

Отзывы: