FOLLOW THE USER’S MANUAL REQUIREMENTS TO ENSURE DURABLE AND 

TROUBLE-FREE OPERATION OF THE UNIT.

SAFETY INSTRUCTIONS

Disconnect the unit from power supply prior to any connection, servicing, maintenance, and 
repair operations. 

Only  qualified electricians with a work permit for electrical units up to 1000 V are allowed 

for installation and maintenance. The present user’s manual should be carefully read 

before beginning works.

•  Single-phase power mains must comply with the acting local electrical norms and standards.
•  Fixed electrical wiring must be equipped with an automatic circuit breaker.
•  The unit must be connected to power mains through a QF automatic circuit breaker integrated 

into the fixed wiring system. The gap between the circuit breaker contacts on all poles must 
be not less than 3 mm. Check the unit for any visible damages of the impeller and the casing 
before starting installation. The casing internals must be free of any foreign objects that can 
damage the impeller blades.

•  While mounting the unit, avoid compression of the casing! Deformation of the casing may result 

in the motor jam and noisy operation. Misuse of the unit and any unauthorised modifications 
are not allowed.

•  Take steps to prevent ingress of smoke, carbon monoxide, and other combustion products into 

the room through open chimney flues or other fire-protection devices. Sufficient air supply 
must be provided for proper combustion and exhaust of gases through the chimney of fuel 

Содержание BLABQUATRO

Страница 1: ...USER S MANUAL BLABQUATRO AXIAL WALL CEILING FAN EN ...

Страница 2: ...2 EN CONTENTS Safety Instructions 4 Delivery set 6 Brief description 6 Operation guidelines 6 Installation and set up 6 Technical maintenance 7 Storage and transportation regulations 7 Warranty 8 ...

Страница 3: ...d maintenance staff must have theoretical and practical training in the field of ventilation systems and should be able to work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country The information in this user s manual is correct at the time of the document s preparation The Company reserves the right to modify the technic...

Страница 4: ...ains through a QF automatic circuit breaker integrated into the fixed wiring system The gap between the circuit breaker contacts on all poles must be not less than 3 mm Check the unit for any visible damages of the impeller and the casing before starting installation The casing internals must be free of any foreign objects that can damage the impeller blades While mounting the unit avoid compressi...

Страница 5: ...e efficient air flow Do not sit on the unit and do not put objects on it This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Ensure that the fan is switched off from ...

Страница 6: ... unit is rated as a Class II electrical appliance INSTALLATION AND SET UP The fan is designed for wall or ceiling mounting with direct air exhaust to the ventilation shaft or into the round air duct of matching diameter Fig 2 Fan installation sequence step 1 Cut off power supply and make sure electricity has been turned off Fig 5 step 2 Run the power cable to the vent hole Fig 6 step 3 Remove the ...

Страница 7: ...a dry closed ventilated premise with temperature range from 5 C to 40 C and relative humidity up to 70 Storage environment must not contain aggressive vapors and chemical mixtures provoking corrosion insulation and sealing deformation Use suitable hoist machinery for handling and storage operations to prevent possible damage to the unit Follow the handling requirements applicable for the particula...

Страница 8: ...installation reinstallation or transporting the product Additional information Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement of the purchased product for a major failure of the product You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount...

Страница 9: ...STIPULATED HEREIN WILL ENSURE A LONG AND TROUBLE FREE OPERATION OF THE UNIT USER S WARRANTY CLAIMS SHALL BE SUBJECT TO REVIEW ONLY UPON PRESENTATION OF THE UNIT THE PAYMENT DOCUMENT AND THE USER S MANUAL WITH THE PURCHASE DATE STAMP ...

Страница 10: ...10 EN a a1 b d e c 1 2 Model Dimensions mm Weight kg a a1 b c d e BLABQUATRO 100 171 151 108 128 100 32 0 56 125 201 178 113 136 125 35 0 73 150 236 207 165 157 150 38 0 9 ...

Страница 11: ...11 EN 3 4 ...

Страница 12: ...12 EN QF L N 5 6 7 8 9 10 11 12 ...

Страница 13: ...13 EN L QF N L N S S L N QF L N L N QF L N Contact of the switch is OPEN Fan runs Contact of the switch is CLOSED Fan does not run 13 BLABQUATRO 100 125 150 BLABQUATRO 100 125 150 S ...

Страница 14: ...14 EN QF L N 14 15 16 17 ...

Страница 15: ...15 EN Quality Inspector s Stamp Manufacture Date Sold by name and stamp of the seller Purchase Date ...

Страница 16: ...Blauberg_Australasia_B174EN 02 www blaubergventilation com au BLABQUATRO BLABQUATRO 100 125 150 ...

Отзывы: