background image

Do not use the unit in a hazardous or explosive environment containing 
spirits, gasoline, insecticides, etc.  

Do not close or block the intake or extract vents in order to ensure 
the efficient air flow. 

Do not sit on the unit and do not put objects on it.  

The timer circuit is under mains voltage. 

 

 

4

WARNING

!

Follow the user's manual requirements to ensure 
durable and trouble-free operation of the unit

Содержание Auto Revers 150

Страница 1: ...EN Auto Revers OPERATION MANUAL ...

Страница 2: ...the acting local electrical norms and standards Fixed electrical wiring must be equipped with an automatic circuit breaker The unit must be connected to power mains through a QF automatic circuit breaker integrated into the fixed wiring system The gap between the circuit breaker contacts on all poles must be not less than 3 mm Check the unit for any visible damage of the impeller and the casing be...

Страница 3: ...re protection devices Sufficient air supply must be provided for proper combustion and exhaust of gases through the chimney of fuel burning equipment to prevent back drafting Sufficient air supply must be provided for proper combustion and exhaust of gases through the chimney of fuel burning equipment to prevent back drafting Transported air must not contain any dust or other solid impurities stic...

Страница 4: ...ides etc Do not close or block the intake or extract vents in order to ensure the efficient air flow Do not sit on the unit and do not put objects on it The timer circuit is under mains voltage 4 WARNING Follow the user s manual requirements to ensure durable and trouble free operation of the unit ...

Страница 5: ...ruction regarding safe use of the unit and understand the risks involved Do not allow children to play with the unit Unit cleaning and maintenance must only be performed by children under adult supervision THE PRODUCT MUST BE DISPOSED SEPARATELY AT THE END OF ITS SERVICE LIFE DO NOT DISPOSE IT AS UNSORTED MUNICIPAL WASTE 5 WARNING Follow the user s manual requirements to ensure durable and trouble...

Страница 6: ...esigned for extended periods of continuous operation without disconnection from the electric mains INSTALLATION The Auto Revers fan installation steps are as follows 1 Cut off power supply Fig 2 2 Remove the front panel of the fan Fig 3 3 Mark the holes on the wall Fig 4 4 Drill the holes in the wall and insert the expansion anchors Fig 5 5 Remove the self tapping screws securing the cable clampin...

Страница 7: ...by releasing the latches Fig 10 4 Connect the power and control cable to the control units according to the wiring diagram 1 5 Install the power and control unit into the hollow space in the wall Fig 11 6 Install the frame the buttons and the plug in the reverse order Fig 12 ATTENTION All the electrical connections to the control unit and the fan must be made using plug in terminal blocks Each ter...

Страница 8: ...inimum technical maintenance interval is 6 months To clean the unit use a soft cloth and a brush soaked in a detergent water solution Fig 14 19 ATTENTION Avoid liquid spills on the electric components Wipe the fan surfaces dry after cleaning TRANSPORTATION AND STORAGE REGULATIONS Transportation with any transportation vehicle in the manufacturer s original package Store the fan in the manufacturer...

Страница 9: ...ex according to IP rating against access to hazardous parts and water ingress IP24 The fan does not require grounding The manufacturer hereby warrants normal operation of the unit for 60 months after the retail sale date provided the user s observance of the transportation storage installation and operation regulations In case of failure due to faulty equipment during the warranty period the consu...

Страница 10: ...10 1 0 5 1 Auto Revers ...

Страница 11: ...11 2 3 4 5 6 7 ...

Страница 12: ...48 R35 2 radii 70 70 A A A A 12 8 9 10 11 12 13 Exhaust supply mode High speed Activation Low speed Reverse operation Deactivation ...

Страница 13: ...4 5 21 22 23 24 25 1 2 3 4 5 11 12 13 14 15 Marking 11 15 onthe controllersocketconnector JMP1 Flow out exhaust White Red Grey Brown Yellow Green White Marking 21 25 onthe controllersocketconnector Marking 1 5 ontheconnecting cablesocketconnector Flow in supply White Red Grey Brown Yellow Green White Marking 11 15 onthe controllersocketconnector Marking 1 5 ontheconnecting cablesocketconnector ...

Страница 14: ...14 14 15 16 17 18 19 ...

Страница 15: ...FICATE OF ACCEPTANCE WARRANTY CARD The fan is recognized as serviceable Stamp of the acceptance inspector Manufacturing date Sold by name of the vendor stamp of the shop Date of sale Auto Revers 150 Auto Revers ...

Страница 16: ...www blaubergventilatoren de Auto Revers_EN v 1 4 ...