VENTO Ergo A50/50-1 Pro

BLAUBERG Company is happy to offer your attention a new high-quality 

single-room reversible unit with heat and humidity recovery 

VENTO Ergo 

A50 Pro

. The solid team of high-qualified professionals with many years of 

working experience, technological innovations in design and production, 

high-quality components and materials from the top worldwide producers 

have become the precondition for the best energy saving unit in its class.

INTRODUCTION

The present operation manual contains technical description, technical 

data sheets, operation and mounting guidelines, safety precautions and 

warnings for safe and correct operation of the unit.

GENERAL

The single-room unit is designed for efficient energy saving supply and 

exhaust ventilation of flats, houses, cottages and other small premises. 

The heat recovery technology is used to minimize ventilation heat losses.

The unit is equipped with a high-tech ceramic heat exchanger that 

provides the utilization of extract air heat energy for warming up of filtered 

supply air flow.  The heat recovery efficiency of the heat exchanger is up to 

91%.

The unit is designed for indoor application with the ambient temperature 

ranging from -20 °C up to +50 °C and relative humidity up to 80%.

The unit is designed for external through-the-wall installation. The unit is 

designed for continuous operation always connected to power mains.

The unit is allowed for operation only after final mounting, that includes 

installation of protecting devices in compliance with DIN EN ISO 13875 (DIN 

EN ISO 12100) as well as other construction safety equipment.

The unit design is regularly improved, so some models may slightly differ 

from those ones described in this operation manual.

SAFETY RULES

The unit complies with the requirements according to the EU norms 

and directives, to the relevant EU-Low Voltage Equipment Directives, EU-

Directives on Electromagnetic Compatibility. 

All operations related to the unit electrical connections, servicing and 

repair works are allowed only after the fan disconnection from power mains.

All mounting and servicing operations are allowed for duly qualified 

electricians with valid electrical work permit for electric operations at the 

units up to 1000 V after careful study of the present operation manual. 

The unit must be grounded! 

Please follow the safety regulations and working instructions (DIN EN 50 

110, IEC 364).

Make sure the impeller and the casing are not damaged before 

connecting the unit to power mains. The casing internals must be free of any 

foreign objects which can damage the impeller blades.

Disconnect the unit from power mains prior to any operations related to 

the unit servicing and repair works.

Misuse of the product or any unauthorized modification are not allowed. 

The unit is designed for connection to AC single-phase power mains, see 

«Technical Data». The unit is rated for permanent operation during non-stop 

power supply. 

Take steps to prevent ingress of smoke, carbon monoxide and other 

combustion products into the room through open chimney flues or other 

fire-protection devices. Sufficient air supply must be provided for proper 

combustion and exhaust of gases through the chimney of fuel burning 

equipment to prevent back drafting.  The maximum permitted pressure 

difference per living units is 4 Pa.

The air must not contain any dust or other solid impurities, sticky 

substances or fibrous materials. The unit is not designed for use in an 

inflammable and explosive medium. 

Do not close or block the unit intake or exhaust vent not to disturb the 

normal  air passage. Do not sit on the unit and do not put objects on the unit.

In case of unusual sounds, smoke disconnect the unit from power supply 

and contact the service centre.

Follow the operation manual guidelines to ensure trouble-free operation 

and long service life of the unit.

Hazardous parts access and water ingress protection standard IP24. 

STORAGE AND TRANSPORTATION RULES

Transportation of the unit is allowed by any vehicle provided the unit is 

transported in the original package and is protected against weather and 

mechanical damages. 

Use hoist machinery for handling and transportation to prevent possible 

mechanical damages of the unit. Fulfil the requirements for transportation of 

the specified cargo type during cargo-handling operations. 

Store the unit in a dry and cool place in the original packing.

The storage environment must not be subjected to any aggressive and/

or chemical evaporations, admixtures, foreign objects that may provoke 

corrosion and damage connection tightness. 

Store the unit in an environment with minimized risk of mechanical 

damages, temperature and humidity fluctuations. 

Do not expose the unit to the temperatures below  +10 °C and above  

+40 °C .

Connection of the unit to power mains is allowed after the unit has been 

kept indoor for minimum two hours.

MANUFACTURER’S WARRANTY

The product complies with the requirements according to the EU norms 

and directives, to the relevant EU-Low Voltage Equipment Directives, EU-

Directives on Electromagnetic Compatibility. 

We hereby declare that the following product complies with the essential 

protection requirements of Electromagnetic Council Directive 2004/108/

EC, 89/336/EEC and Low Voltage Directive 2006/95/EC, 73/23/EEC and 

CE-marking Directive 93/68/EEC on the approximation of the laws of the 

Member States relating to electromagnetic compatibility. 

The manufacturer hereby warrants normal operation of the product over 

the period of 2 years from the retail sale date provided observance of the 

installation and operation regulations.

In case of failure due to manufacturing fault during the warranty period 

the consumer has the right to exchange it.

If case of no confirmation of the sale date, the warranty period shall be 

calculated from the manufacturing date.

The replacement is offered by the Seller. 

The manufacturer shall not be liable for any damage resulting from any 

misuse of or gross mechanical interference with the unit.

Fulfil the  operation manual requirements to ensure a trouble-free and 

long service life of the unit. 

Содержание Vento Expert A50-1 Pro

Страница 1: ...OPERATION MANUAL VENTO Ergo A50 Pro VENTO Ergo A50 S Pro VENTO Ergo A50 1 Pro VENTO Ergo A50 1 S Pro SINGLE ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY...

Страница 2: ...on and storage rules 3 Manufacturer s warranty 3 Design and operating logic 4 Modifications and options 5 Delivery set 5 Technical data 6 Mounting 7 Connection to power mains 10 Unit control 11 Mainte...

Страница 3: ...ion manual prior to any electric installations Connection of the unit to power mains is allowed by qualified professionals WARNING Read the operation manual prior to any electric installations Connect...

Страница 4: ...y Take steps to prevent ingress of smoke carbon monoxide and other combustion products into the room through open chimney flues or other fire protection devices Sufficient air supply must be provided...

Страница 5: ...h a motor meter with non volatile memory After 90 days non stop operation the sound signal reminds of the need to clean or replace the filters The signal is repeated every 5 minutes until the filters...

Страница 6: ...Ergo A50 1 Pro Unit with a flat front panel for 250 up to 470 mm walls VENTO Ergo A50 1 S Pro Unit with a flat front panel for 120 up to 300 mm walls DELIVERY SET Unit 1 item Mounting plate 1 item Fix...

Страница 7: ...Max air flow m3 h 13 27 51 RPM min 1 580 760 1378 Sound pressure level at 3 m distance dBA 19 22 29 Transported air temperature C from 20 up to 50 Filter extract supply G3 Heat recovery efficiency up...

Страница 8: ...the surface of the mounting plate The unit is designed for through the wall mounting in the building outer wall Mounting sequence 1 Prepare a round core hole through the outer wall The size is shown...

Страница 9: ...S Pro Mark the holes with the master plate from the delivery set Drill 40 mm deep holes for the dowel 6x40 8 Insert the dowels 6x40 from the delivery set into the holes 9 Disassemble the outer ventil...

Страница 10: ...ewallwiththescrews4x40fromthedelivery set Fig 15b models VENTO Ergo A50 S Pro and VENTO Ergo A50 1 S Pro Fix the back part of the outer ventilation hood to the wall with the screws 4x40 from the deliv...

Страница 11: ...one in the same way etc Up to 10 units may be connected in series fig 18 For electric installation use a five wire cable not included into the delivery set with the cable cross section not below 0 5 m...

Страница 12: ...THE NEXT UNIT 2 Connection in series of above 10 units In case of connection above 10 units power is supplied to the 11th unit L and N terminals not from the previous unit but from power mains The co...

Страница 13: ...Heat Recovery mode If the indoor humidity exceeds the set point the unit switches to the third speed If the humidity is within 5 the unit operates at the second speed If the indoor humidity is below...

Страница 14: ...er located after the heat exchanger Clean the filters as often as required but at least once in three months After 90 days non stop operation the sound signal reminds of the need to clean or replace t...

Страница 15: ...e troubleshoot the connection error Jammed motor soiled impeller blades Turn the unit off Troubleshoot the motor jam and the impeller clogging Clean the blades Restart the unit Automatic switch trippi...

Страница 16: ...tes relating to electromagnetic compatibility This certificate is issued following test carried out on samples of the product referred to above Approval mark Manufacturing date____________________ Com...

Страница 17: ...____________________________________ _______________________________________________________________________________________ ___________________________________________________________________________...

Страница 18: ...____________________________________ _______________________________________________________________________________________ ___________________________________________________________________________...

Страница 19: ...____________________________________ _______________________________________________________________________________________ ___________________________________________________________________________...

Страница 20: ...www blaubergventilatoren de VENTO Ergo A50 Pro v 3 6 EN...

Отзывы: