background image

www.blaubergventilatoren.de

SE VENTO Expert W

11

CERTIFICATE OF ACCEPTANCE

Unit Type

Sensor control panel with integrated Wi-Fi

Model

SE VENTO Expert W

Serial Number
Manufacture Date

Quality Inspector’s

Stamp

SELLER INFORMATION

Seller

Seller’s Stamp

Address
Phone Number
E-mail
Purchase Date

This is to certify acceptance of the complete unit delivery with the user’s manual. The warranty terms are 
acknowledged and accepted.

Customer’s Signature

INSTALLATION CERTIFICATE

The SE VENTO Expert W unit is installed pursuant to the requirements stated in the present user's 
manual.

Installation Stamp

Company name
Address
Phone Number
Installation

Technician’s Full Name
Installation Date:

Signature:

The unit has been installed in accordance with the provisions of all the applicable local and national construction, 
electrical and technical codes and standards. The unit operates normally as intended by the manufacturer.

Signature:

WARRANTY CARD

Unit Type

Sensor control panel with integrated Wi-Fi

Seller’s Stamp

Model

SE VENTO Expert W

Serial Number
Manufacture Date
Purchase Date
Warranty Period

Seller

Содержание SE Vento Expert W

Страница 1: ...Sensor control panel with integrated Wi Fi USER S MANUAL EN SE VENTO Expert W ...

Страница 2: ...hnical norms and standards must be observed when installing and operating the unit Disconnect the unit from the power supply prior to any connection servicing maintenance and repair operations Only qualified electricians with a work permit for electrical units up to 1000V are allowed for installation and maintenance The present user s manual should be carefully read before beginning works Check th...

Страница 3: ...use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance The connection to the supply mains must be made through a means of d...

Страница 4: ...toren de PURPOSE DELIVERY SET NAME NUMBER Control panel 1 pc Mounting box 1 pc User s manual 1 pc Packing 1 pc The sensor control panel is designed to control the TwinFresh Expert from version V 2 and TwinFresh Style Wi Fi series ventilators ...

Страница 5: ...EQUIRED TOOLS AND MATERIALS MOUNTING CONNECTION AND SETUP CHOOSING LOCATION FOR CONTROL PANEL INSTALLATION Examples of wireless alternatives and system operation scenarios Example 1 direct control panel connection to master ventilator without using a router The control panel must be installed within the range of the Wi Fi access point built into the master ventilator Master ventilator Wi Fi access...

Страница 6: ...uter to one of the Wi Fi access points see ventilator user s manual Pair the ventilator with the first group of the panels Connect the ventilator to the other Wi Fi access point see ventilator user s manual Pair the ventilator with the other group of the panels ATTENTION IRRESPECTIVE OF THE SELECTED CONNECTION PATTERN THE PANEL MUST BE WITHIN THE RANGE OF THE WI FI ACCESS POINT BUILT INTO THE VENT...

Страница 7: ...lf tapping screws purchased separately 2 Connect the control panel according to the electrical connections diagram N L 110 230 V 50 60 Hz 3 Unfasten gently the latches on the lower part of the glass control panel using a screwdriver Take off the control panel Then disconnect the sensor board from the connector on the casing 4 Fasten the control panel casing to the mounting box with screws The scre...

Страница 8: ...et to 4 hours by default or the Night mode speed 1 enabled by the timer set to 8 hours by default To activate the Party mode press the button and then immediately press the button To activate the Night mode press the button and then immediately press the button The filter contamination indicator activates automatically after 90 hours of unit operation Respond to the alert by replacing or cleaning ...

Страница 9: ...ble hoist machinery for handling and storage operations to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo The unit can be carried in the original packaging by any mode of transport provided proper protection against precipitation and mechanical damage The unit must be transported only in the working position Avoid sharp blows scratc...

Страница 10: ...ion dismantling unit setup To benefit from warranty repair the user must provide the unit the user s manual with the purchase date stamp and the payment paperwork certifying the purchase The unit model must comply with the one stated in the user s manual Contact the Seller for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with ...

Страница 11: ...STALLATION CERTIFICATE The SE VENTO Expert W unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Technician s Full Name Installation Date Signature The unit has been installed in accordance with the provisions of all the applicable local and national construction electrical and technical codes and stan...

Страница 12: ...www blaubergventilatoren de B133 2EN 03 ...

Отзывы: