DELIVERY SET

 Timer or sensor with timer - 1 item; 

 Screws and dowels: 

 - 2 sets for wall surface mounting; 

 - 4 sets for wall flush mounting.

 Operation manual - 1 item; 

 Packing box - 1 item. 

TECHNICAL DATA

Table 1. Technical data

Parameters

TE 1.5

TI 1.5

HSE 1.5

HSI 1.5

LSE 1.5

LSI 1.5

IRSE 1.5

IRSI 1.5

Supply voltage, 50 Hz [V]

220-240

Load current [A]

1.5

Output power [VA]

330

Operating humidity range [°C]

from + 1 up to + 45

Ingress Protection Rating 

IP30

Overall dimensions [mm]

162x80x70

DESIGN

The casing is made of plastic. The front panel design 

is shown in fig. 1: 

1 - operation light indicator

2 - photosensor (only for LSE/LSI)

3 - control knob for setting turn-off delay time from 2 

up to 30 minutes

4 - control knob for setting humidity level (only for 

HSE/HSI) or illumination intensity (only for LSE/LSI) 

5 - motion sensor (only for IRSE/IRSI)

The  TE / HSE/ LSE / IRSE models are for the wall surface 

mounting and the TI / HSI / LSI / IRSI models are for flush 

mounting.

3

mi

n

mi

n

1

2

4

5

Fig. 1. Design

Turn-off delay timer TE/TI 1.5 

After the external switch, for example, a light switch, 

sends a control signal to the LT input terminal, the timer 

applies voltage to the connected fan. 

When the control voltage is off the timer keeps 

sending power supply to the fan within the set time 

period adjustable from 2 up to 30 minutes.

Humidity sensor with timer  HSE/HSI 1.5

After the external switch, for example, a light switch, 

sends a control signal to the LT input terminal or if the 

indoor humidity exceeds the set point adjustable from 

60% up to 90%, the humidity sensor applies voltage to 

the connected fan. 

When the control voltage is off or in case of  the indoor 

humidity drop below the set point, the humidity sensor 

with timer  keeps sending power supply to the fan within 

the set time period adjustable from 2 up to 30 minutes.

Photo sensor with timer LSE/LSI 1.5

After the external switch, for example, a light switch, 

sends a control signal to the LT input terminal or if the 

illumination intensity in the room exceeds the set point, 

the photo sensor  applies voltage to the connected fan. 

When the control voltage is off or if the illumination 

intensity decreases, the photo sensor with timer keeps 

sending power supply to the fan within the set time 

period adjustable from 2 up to 30 minutes.

Motion sensor with timer IRSE/IRSI 1.5

After the external switch, for example, a light switch, 

sends a control signal to the LT input terminal or in case 

of the motion registration in the sensitivity area from 1 

up to 4 meters with the horizontal viewing angle 100°, 

the motion sensor  applies voltage to the connected fan. 

When the control voltage is off or when no motion 

more is detected, the motion sensor with timer keeps 

sending power supply to the fan within the set time 

period adjustable from 2 up to 30 minutes. 

OPERATION MODES

The timer and the sensor with timers have three 

operation modes: 

Standby mode

 - the timer/sensor with timer receives 

no signal from sensors or from the external switch. The 

connected fan does not run. The light indicator on the 

front panel blinks red once in 5 seconds. 

Active mode

 is activated by operation of the motion 

sensor, closing of the external switch, response of 

the humidity sensor or photo sensor. The connected 

fan runs.  The light indicator on the front panel has 

permanent glow. 

Timer mode

 is activated after no response of the motion 

sensor, opening of the external switch, decrease of the 

humidity or illumination intensity below the set point. 

T_HS_LS_IRS_v.2(3)_DE_EN_105x148.indd   12

22.09.2015   14:22:57

Содержание HSE 1.5

Страница 1: ...BETRIEBSANLEITUNG TE 1 5 TI 1 5 HSE 1 5 HSI 1 5 LSE 1 5 LSI 1 5 IRSE 1 5 IRSI 1 5 TIMER SENSOREN MIT TIMER T_HS_LS_IRS_v 2 3 _DE_EN_105x148 indd 1 22 09 2015 14 22 50...

Страница 2: ...hriften 3 Lager und Bef rderungsvorschriften 3 Herstellergarantie 3 Lieferumfang 4 Technische Daten 4 Aufbau 4 Betriebsarten 4 Montage 5 Anschluss an das Stromnetz 6 Diagnose und Abhilfe 6 Abnahmebesc...

Страница 3: ...ur und Feuchtigkeitsschwankungen minimiert sind bei einer Umgebungstemperatur von 5 C bis 40 C gelagert werden HERSTELLERGARANTIE Das Ger t entspricht den Europ ischen Normen und Standarten den Richtl...

Страница 4: ...hte von 60 bis zu 90 berschreitet legt der Feuchtigkeitssensor mit Timer die Spannung an den angeschlossenen L fter an Wenn die Steuerspannung abgeschaltet wird oder falls die Raumfeuchtigkeit unter d...

Страница 5: ...festigen Sie die Frontplatte mit den 4 mitgelieferten Schrauben und installieren Sie die Dekorabdeckung Abb 3 7 WARNUNG Stellen Sie sicher dass das Ger t nicht besch digt ist Verwenden Sie kein besch...

Страница 6: ...ervice undWartungsarbeitensindnurvom Fachpersonalgestattet das bereineg ltigeZulassungf relektrischeArbeitenverf gt B L fter S externer Schalter T Timer Sensor mit Timer DIAGNOSE UND ABHILFE Alarm Eve...

Страница 7: ...tes auf das oben genannte ausgestellt Die bereinstimmung des Produktes mit den Anforderungen in Bezug auf elektromagnetische Vertr glichkeit basiert auf den obigen Normen Pr fzeichen Herstellungsdatum...

Страница 8: ...T_HS_LS_IRS v 2 3 DE www blaubergventilatoren de T_HS_LS_IRS_v 2 3 _DE_EN_105x148 indd 8 22 09 2015 14 22 55...

Страница 9: ...OPERATION MANUAL TE 1 5 TI 1 5 HSE 1 5 HSI 1 5 LSE 1 5 LSI 1 5 IRSE 1 5 IRSI 1 5 TIMER SENSORS WITH TIMER T_HS_LS_IRS_v 2 3 _DE_EN_105x148 indd 9 22 09 2015 14 22 56...

Страница 10: ...ortation rules 11 Manufacturer s warranty 11 Delivery set 12 Technical data 12 Design 12 Operation modes 12 Mounting 13 Connection to power mains 14 Troubleshooting and fault handling 14 Acceptance ce...

Страница 11: ...perature from 5 C up to 40 C MANUFACTURER S WARRANTY The product complies with the requirements according to the EU norms and directives to the relevant EU Low Voltage Equipment Directives EU Directiv...

Страница 12: ...ndoor humidity drop below the set point the humidity sensor withtimer keepssendingpowersupplytothefanwithin the set time period adjustable from 2 up to 30 minutes Photo sensor with timer LSE LSI 1 5 A...

Страница 13: ...in the wall to the installation place 4 Lean the casing against the wall and mark the openings for the dowels fig 2 3 5 Drill the holes in the wall and install 5x25 dowels fig 2 4 6 Route the wires th...

Страница 14: ...hedevice Allmountingandservicingoperationsareallowedforduly qualifiedelectricianswithvalidelectricalworkpermitforelectricoperationsaftercarefulstudyofthepresentuser smanual B fan S external switch T t...

Страница 15: ...e is issued following test carried out on samples of the product referred to above Assessment of compliance of the product with the requirements relating to electromagnetic compatibility was based on...

Страница 16: ...T_HS_LS_IRS v 2 3 EN www blaubergventilatoren de T_HS_LS_IRS_v 2 3 _DE_EN_105x148 indd 16 22 09 2015 14 22 57...

Отзывы: