www.blaubergventilatoren.de
Freshbox 100
10
5.
To install an additional extract spigot, remove the
plug on the rear part of the unit.
Undo the screws, remove the plug and fix a flange in
its place using screws.
6.
CAUTION!
Install the condensate preheater before fixing
the unit to the wall (see the User’s manual of the
electric heater).
Insert the connecting cables of the heater, external
humidity sensor or CO2 sensor into the control unit
through the corresponding holes on the back wall of
the unit.
• Open the unit.
• Undo the screws securing the shield plate and
remove it.
• Remove the heat exchanger.
• Lift the unit and insert the spigots into the
corresponding air ducts installed in the wall.
CAUTION!
Remove the magnetic plug from the extract grille
if an additional outlet spigot is not installed.
• Fix the unit on the wall using the supplied screws
and dowels.
• Install the heat exchanger back to the unit.
• Install the humidity or CO2 sensor (available
separately) on the bracket.
• Make electrical connections, see “Connection to
power mains”.
• Reassemble the unit in the reverse order.
7.
Fix the unit on the wall using the supplied screws
and expansion anchors.
Install the heat exchanger back and close the unit door.
Cut a part of the drain pipe protruding outside to
a length not more than 10 mm.
Fix the outer hood on the outer wall of the building
(see the ventilation hood installation manual).
10 mm