background image

Box-D

USER'S MANUAL 

EN

CEILING FAN 

Содержание 4058448013898

Страница 1: ...Box D USER S MANUAL EN CEILING FAN ...

Страница 2: ... device operation by the person responsible for their safety The fan may not be used to handle air containing highly flammable substances or vapours such as alcohol petrol etc The fans take 220 240 V 50 60 Hz single phase alternating current Children being supervised not to play with the appliance Disconnect the damper from the power supply electric mains prior to any work on the unit Power mains ...

Страница 3: ...e must not exceed the limit values given in Table 1 The fan is designed for installation between the floor slab and the suspended ceiling attached to the ceiling structure on mounting brackets or to a wall on side mounts Box D 100 and Box D 125 only The fan is designed for extended periods of continuous operation without disconnection from power mains The products meet the requirements of IPX4 haz...

Страница 4: ...uency Hz Power W Current A 3 Maximum air capacity m h R P M Sound pressure level at 3 m distance dB A o Max transported air temperature C IP rating Fan type Dimensions mm Weight kg Box D 125 L Box D 125 Box D 100 L Box D 100 Box D 150 Fan type Pict 1 220 240 50 60 1 220 240 50 60 1 220 240 50 60 1 220 240 50 60 1 220 240 50 60 1 220 240 50 60 1 2 Box D 160 Box D 100 L Box D 100 Box D 125 L Box D 1...

Страница 5: ...rille 5 with air filter 6 is attached to the casing with screws Decorative front panel 7 locks into the slots on grille 5 The casing houses a single phase electric motor with a centrifugal impeller and backward curved blades The electric motor has integrated thermal protection and restarts automatically The replacement of parts of the safety suspension system device shall be performed by the manuf...

Страница 6: ...e suspended ceiling must be within 165 390 mm The fan installation steps are given in Fig 5 6 The power is supplied via an external terminal box mounted to the fan casing WARNING If unusual oscillating movement is observed immediately stop using the ceiling fan and contact the manufacturer its service agent or suitably qualified persons The fan is to be installed so that the blades are more than 2...

Страница 7: ...280 mm S 1 3 5 7 2 4 6 8 Box D 100 L Box D 100 Box D 125 L Box D 125 Figure 5 www blaubergventilatoren de 7 Box D ...

Страница 8: ...8 www blaubergventilatoren de Box D S 403 5 mm 250 mm Box D 150 Box D 160 1 3 5 2 4 6 Figure 6 ...

Страница 9: ...st be equipped with a switch built into the stationary wiring to disconnect all the mains phases The location of the S external switch must ensure unobstructed access for shutting down the fan quickly if required The conductor cross section values are given for reference only while the actual selection must be based on the maximum permissible wire heating which depends on the wire type its insulat...

Страница 10: ...ated inside the fan casing in accordance with the Wiring Diagram and the terminal designations Fig 7 The terminal designation diagram is given on a label inside the terminal box 2 3 4 The steps for connecting the fan to power mains are given on Fig 8 L N X1 1 2 3 N L S 220 240 V 50 60 Hz 4 Figure 7 Figure 8 ...

Страница 11: ...acement steps are given in Fig 9 The impeller blades must be thoroughly cleaned from dust and dirt every 6 months Take the necessary measures to prevent penetration of smoke carbon monoxide and other combustion products into the spaces through open smoke ducts or other fire safety infrastructure as well as prevent back flow of gases from any appliances which produce gas flame or naked flame The tr...

Страница 12: ...of a faulty unit being the subject of warranty repair application replaced over the warranty period shall inherit the warranty period and warranty service terms which apply to the entire unit For the avoidance of doubt this means that neither the said components nor the entire unit shall be covered by an additional warranty period In the event of any malfunctions in the fan operation during the wa...

Страница 13: ...turer and its official distributors RELATED DAMAGE LIABILITY WAIVER The manufacturer shall not be liable for any deterioration of health or damage to equipment caused by violating the provisions of the present User s Manual unit misuse or gross mechanical tampering The company does not provide compensation for any related damage e g unit relocation and re connection direct or indirect damages etc ...

Страница 14: ...nical codes and standards The fan operates normally as intended by the manufacturer Signature Installation Company Stamp Unit Type CEILING FAN Model Box D ____________ Serial Number Manufacture Date is compliant with the technical specifications and is hereby declared ready for service We hereby declare that the product complies with the essential protection requirements of Electromagnetic Council...

Страница 15: ...Unit Type CEILING FAN Model Box D _________ Serial Number Purchase Date Warranty Period Seller Seller s Stamp WARRANTY CARD WARRANTY CARD Purchase Date www blaubergventilatoren de 15 Box D ...

Страница 16: ...www blaubergventilatoren de ...

Отзывы: