20
6.4 Water separator
The water separator filters dirt particles, oil and water from the air.
It is recommended to replace the filter after every 450 operating hours.
NEVER
remove the water separator from the pulse system. The water separator keeps the pulse system from
clogging up with oil, dirt and water.
1.
Head
26. Valve
27. Floater
28. O-ring
29. Bowl
30. O-ring
31. Filter element
36. Louver
This spitter type drain operates momentarily
when a rapid change in air flow occurs or when the supply
pressure is reduced.
The separated water will be drained in the ‘Drain Box’
It has to be emptied daily.
Checking the filter:
Unscrew 29. Bowl and keep it upright, so that the Floater and
o-ring will stay in place.
Check 31. Filter element on contaminants and calcium deposits.
Clean the filter with warm water and pressurised air or replace if
needed.
>>> AIRFLOW >>>
>>> AIRFLOW >>>
Notice the arrow on the water separator, showing
the correct airflow.