background image

 

16 

5.7 

Silencer 

 
The silencer on top of the dust extractor reduces the noise emission but can also be used to adjust the suction 
power of the machine. Close it a little bit for less suction power, and open it for more suction power. 
 
 
 

6. Maintenance 

 
Pay attention to Chapter 3 

"Safety"

 during maintenance and repair works.  

 
Failures due to inadequate or incorrect maintenance may generate very 

high repair costs

 and long standstill 

periods of the dust collector. 

Regular

 maintenance therefore is imperative. 

 
Operational safety and service life of the dust collector depend, among other things, on proper maintenance. 
 
The following table shows recommendations about time, inspection and maintenance for the normal use of the 
dust collector. 

 

Operating hours/ 

time period 

Inspection points, maintenance instructions 

12 h after repairing 

Check all accessible screw connections for tight seat. 

Daily and prior to 
starting work 

Check that all safety devices working adequate. 
Check the electric connections for sediments of dirt or foreign bodies. 
Check the electric motors for dirt and other contaminants. 
Check all safety devices working adequate. 
Check the function of the residual current operated device.  
Check the hose connections for tightness and fixed seat. 
Check all hoses on the machine for damages or leakage. 
Make sure that the dust bin is emptied 
Make sure there is no water in the air pressure tank. 

Every 3 months 

Clean the upper section of the filter unit. 
Clean or replace the air filter of the compressor. 
Clean or replace the filter inside the water separator. 
Check the tension of the V-belts 

Annually 

Full overhaul and cleaning of the complete machine. 

 
 
The time indications are based on uninterrupted operation. When the indicated number of working hours is not 
achieved during the corresponding period, the period can be extended. However a full overhaul and a technical 
inspection must be carried out at least once a year, consisting of inspection of filters for damage, air tightness 
of the machine and proper function of the control mechanism. This technical inspection shall be carried out by 
the manufacturer or an instructed person. 
 
Due  to  different  working  conditions  it  can’t  be  foreseen  how  frequently  inspections  for  wear  check’s, 
inspection,  maintenance  and  repair  works  ought  to  be  carried  out.  Prepare  a  suitable  inspection  schedule 
considering your own working conditions and experience. 
 
Pay attention to unusual noises or strong vibrations. Check for the cause of every big change. Call a technician 
if you have doubts about the cause or when a repair without a technician seems not possible without damages. 
Only use genuine Blastrac spare parts. 
 
Our specialists will be happy to assist you with more advice. 

Содержание BDC-66

Страница 1: ...Original instructions in English Any other language is a translation of the original instructions OPERATING INSTRUCTIONS BDC 66 VERSION 1 5...

Страница 2: ...n By competent person Inspection before initial operation on __________________________________________ By __________________________________________ Date of initial operation ________________________...

Страница 3: ...perating 14 5 1 Before switch on 14 Extension lead 14 Checking correcting the turning direction 14 5 2 Starting stopping the machine 14 5 3 Working with the machine 14 5 4 Interrupting work 15 5 5 Emp...

Страница 4: ...or removing noncombustible non explosive dust or substances The BDC 66 must not be used for pathogenic or carcinogenic substances like asbestos Do not use the machine in the presence of dangerous atmo...

Страница 5: ...system The conditioned air then passes a control valve which regulates the system pressure and then builds up pressure in the pulse tank The pressurized air is used to generate a pulse of air which cl...

Страница 6: ...mply with the National regulations i Never use the machine when the surface is not clear and if there is a risk of stumbling or tripping j Remove electrical cables and dust hose from the surface to be...

Страница 7: ...ry Keep your hair clothing and gloves away from moving parts c Personnel must tie back long hair and not wear loose clothing or jewellery including rings d Stay alert watch what you are doing and use...

Страница 8: ...t and horizontal surface before operation w The machine must be braked by actuating the levers on the wheels with brakes x Do not allow the operation of the machine while it is moving during operation...

Страница 9: ...hine i Before every use check the lifting eye and welds for deformation damages cracks corrosion and wear j Only lift the machine on the lifting eye Page 5 item 10 k When lifting the machine from the...

Страница 10: ...CE mark on this machine Wear protecting gloves Safety shoes obliged Consult the manual before operating the machine Name address and CE mark The machine type The net weight of the machine in kilogram...

Страница 11: ...ty functions and operating functions must work correct Check all screws and other fasteners for tightness No loose bolts and or nuts are permitted Check the electrical components cables and connection...

Страница 12: ...utton cuts off all power to the machine and the extension lead Turn to unlock 7 Extension lead The extension lead on the vacuum cleaner may only be used as an extension lead for Blastrac machines Cont...

Страница 13: ...the dust hose The machine should only be moved around when the dust hose and power supply cable are disconnected WARNING Always make sure all rotating parts have come to a complete standstill and the...

Страница 14: ...pressing the fan OFF and compressor OFF buttons Check the rotating direction of the fan motor indicated with an arrow Correcting the turning direction of the motors Switch off all motors and put the...

Страница 15: ...dust mask of at least class FFP3 The level of the dustbin must be regularly checked The periods are dependent on the type of surface preparation being carried out Safety precaution Pay attention to th...

Страница 16: ...ses on the machine for damages or leakage Make sure that the dust bin is emptied Make sure there is no water in the air pressure tank Every 3 months Clean the upper section of the filter unit Clean or...

Страница 17: ...en working in a confided space Secure the maintenance area if necessary 6 1 When to change the filters If the vacuum cleaner loses suction power first try the following before continuing 1 Check if th...

Страница 18: ...ly When mounting new filter cartridges pay attention that their gaskets at the upper side lies firm at the sheet steel of the filter chamber A tilt of the filter cartridge results in leakage and conta...

Страница 19: ...0 bar This provision is to ensure that when there is a defect in the Control valve the pressure in the pulse tank remains within safe limits If the pressure of 6 bar is not reached it is possible that...

Страница 20: ...e separated water will be drained in the Drain Box It has to be emptied daily Checking the filter Unscrew 29 Bowl and keep it upright so that the vlotter and o ring will stay in place Check 31 Filter...

Страница 21: ...rives have to be checked every 3 months 6 7 V belt mounting Reduce the distance between the driving motor and the bearing to release the tension of the V belt drive Carefully put the V belt in the gro...

Страница 22: ...1822 2009 and classified H13 or H14 to test result 7 2 Difference vacuum gauge A vacuum gauge measures the difference between the under pressure above the filters and inner filter house This readout...

Страница 23: ...work the dustcollector does not have to be stopped 1 2 3 4 5 Airflow 1 Connect the handle and make sure the valve is open 2 Slide the big bag as high up as possible as shown in the picture and fasten...

Страница 24: ...or wrong settings See above Contact Blastrac No suction power Dirty filter cartridges Foreign air leaks in the dust container Obstructed or ripped dust hose Check the tension of the blower fan V belt...

Страница 25: ...ium shot blaster 1078m3 hr Air flow without hose 2200m3 hr Vacuum 51 hPa mbar Dust hose connection 127mm 150 mm Dust bin capacity 150L Longo pack capacity 25L Dust bag 67 5L 145L Noise emission level...

Страница 26: ...This may significantly decrease the exposure level over the total working period Identify additional safety measures to protect the operator from the effects of noise such as proper and regular mainte...

Страница 27: ...gton Sheffield South Yorkshire GB S25 3QY England Tel 0044 1909 56 91 18 Fax 0044 1909 56 75 70 Info blastrac co uk Blastrac Germany Richard Byrd Stra e 15 D 50829 K ln Ossendorf Tel 0049 221 70 90 32...

Отзывы: