15
5.4
Interrupting work
When temporarily interrupting the work (1/2 hour – 1 hour), turn off the fan motor only. Pulse
cleaning of the filter system will continue and will increase the life-time of the filter cartridges.
During a longer stand still of the dust collector, first switch off the fan unit. Let the pulse cleaning cycle
run for +/- 5 minutes. Switch off the compressor unit and Main-switch.
Disconnect the power-supply cable.
Close the silencer when the machine is not working, so there is no change that water or dirt gets in.
Prevent unauthorized persons from getting access to the dust collector or take measures to prevent
unauthorized working with the equipment.
IMPORTANT NOTE !
Always close off the inlet of the dust collector when running the pulse cleaning cycle!
Failure to do so results in blown out dust, which can be hazardous to the health !
5.5
Emptying the dust bin
Operators should observe any safety regulations appropriate to the materials being handled.
ATTENTION! Wear a dust mask of at least class FFP3!
The level of the dustbin must be regularly checked. The periods are dependent on the type of surface
preparation being carried out.
Safety precaution:
Pay attention to the increased weight of the dustbin when you loosen the hopper toggle
clamps. Loosen the clamps with caution!
Flip the protectors up and grab the red handles of the toggle clamps. Carefully move them up until they can be
unhooked. Remove and empty the dustbin.
5.6
Replacing a bigbag
ATTENTION! Wear a dust mask of at least class FFP3!
1
Close the butterfly valve with the control handle.
2
Remove and close the funnel of the BigBag.
3
Slide the bigbag off the support plate.
4
Place a new bigbag, sleeve the funnel on and secure it
with the pull strap.
5
Open the butterfly valve with the control handle.
Close the BigBags properly and make sure they don’t get punctured or ripped. A leaking BigBag can cause a
big mess and potentially be dangerous to the health.
Description
Part
number
Qty.
Big Bag 67,5 ltr E06311
1
Big Bag 145 ltr
E09418
1
LongoPac
cassette
BLS-1058
4x20mtr.
NOTE: The butterfly valve should always be opened during operation,
only close it for changing the bigbag or transport.