2.0 Owner/Operator Responsibilities
1. The owner/operator shall provide site electrical power and observe operation
ampere maximums according to the following chart.
3-Phase/60 Hertz Site Power Requirements
Total FLA
LARGEST MOTOR FLA @ SUPPLY VOLTAGE
12.3 AMPS
7.6 AMPS
208/230 V
2. The owner/operator shall only use personnel who have been trained by a Blastrac
Technician for the operation and maintenance of Blastrac equipment.
3. The operator shall provide the necessary consumable components for the surface
preparation equipment in accordance with the recommendations of a Blastrac
technician so that the machine will operate at maximum efficiency.
4. The operator shall be responsible for the observance of all safety precautions
expressed in this manual.
5. The operator shall perform all maintenance and basic repair functions as stated and
described in this manual.
6. The operator shall dispose of all dust collector refuse in accordance with the
appropriate state and federal regulations.
7. The operator shall provide the minimum following tools and accessories:
Hammer Screwdrivers
Wrench Set
VOM (meter)
5/16” Allen Wrench
Magnetic Broom