
26
Connecting to electricity
The manufacturer disclaims any
responsibility should these safety
instructions not be carried out.
The oven is designed to be connected to
230-240 V (50 Hz) electricity supply.
The oven has an easily accessible terminal
block which is marked as follows.
Letter L
Live terminal
Letter N
Neutral terminal
Earth
The cable used (of the types: H07 RN-F, H05
RN-F, H05 RR-F, H05 VV-F, H05 V2V2-F
T90, H05 BB-F) must have a min. cross
section of 1.5 mm
2
.
In order to connect it to the oven it is
necessary to remove the hatch at the back
of the oven to reach the terminal block.
For direct connection to the mains supply a
two pole switch with a minimum rating of 13
A and a minimum distance of 3 mm between
its contacts must be fitted between the
supply and appliance.
This switch must not break the yellow/green
earth cable at any point.
The appliance must be earthed
Important
After installation and connecting, the cable
must be placed so that is cannot at any point
reach a temperature more than 50°C above
the ambient temperature. Before the
appliance is connected check that:
- the main fuse and the domestic
installation can support the load;
- the power supply is properly earthed;
- the double pole switch used to connect
the appliance to the supply is easily
accessible after installation.