![Blanco BFD9054WX Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/blanco/bfd9054wx/bfd9054wx_instruction-manual_2768515027.webp)
2
7
INSTRUCTIONS FOR THE INSTALLER
18
18B
GAS CONNECTION
This appliance shall be installed only by
authorised personnel and in accordance with
the manufacturer’s installation instructions,
local gas fitting regulations, municipal building
codes, water supply regulations, electrical wiring
regulations, AS 5601 - Gas Installations and any
other statutory regulations.
The appliance is adjusted to work with the gas
indicated on the label which is applied on the
glass-window of the oven door and on the cooker
packing.
Installation for Natural gas
Connect regulator (B) to fitting (A) which is then
fitted to elbow (F). Ensure arrow on regulator
point in the direction shown. Fitting (D) to be
supplied by installer (fig. 18). Adjust regulator to
give test-point pressure given on data label on
<TECHNICAL FEATURES> paragraph, with one
large or one medium burner alight at maximum.
Position of regulator (fig. 18)
The stove must be installed on legs which come
with the product, a gas pipe between fitting
(A) and (B) will allow location of the regulator
(B) underneath the stove for adjustment and
maintenance.
Installation for Propane Gas (fig. 18A)
Connect by using a copper pipe starting, from the
threaded fitting of elbow (F) .
Installation using flexible connection
As an option, the cooker may be installed with
a flexible connection hose, which complies with
AS/NZS 1869 (AGA Approved), 10 mm ID, class
B or D, Minimum 1000 mm - Maximum 1200 mm,
as an alternative connection.
• All cookers offer left or right hand connection.
The manifold has a flat flair over which is
inserted a screw nut male ½” gas (fig. 18B).
• An isolating tap and pressure regulator must
be fixed to the rear wall and the flexible pipe
attached by means of a union connector.
• The gas connection and isolating tap must be
accessible to a service person or inspector.
•
The hose assembly must be installed in
accordance with AS5601 for a high level
connection. The hose should not be subjected
Note: When the regulator is fitted at the rear of
the cooker at least 60 mm clearance is required.
to abrasion, kinking or permanent deformation
and should be able to be inspected along its
entire length. Unions compatible with the hose
fittings must be used and connections tested
for gas leaks. The fixed consumer piping outlet
should be at approximately the same height
as the cooker connection point, pointing
downwards.
• The hose should be clear of the floor when the
cooker is in the installed position. The anti-
tilting chain supplied should be anchored to the
lower hook fixed to the wall so that the chain
prevents
strain on the hose connections when the
cooker is pulled forward.
18A
Содержание BFD9054WX
Страница 1: ...Instruction Manual for BLANCO 90cm Freestanding Cooker BFD9054WX 461308250_001 10 2013 ...
Страница 10: ...10 ...
Страница 21: ...Open the tabs and pull out the telescopic rail by pulling upwards Telescopic rail extracted 21 ...
Страница 32: ...32 TECHNICAL FEATURES WIRING DIAGRAM COOKER BFD9054WX ...
Страница 33: ...33 We appreciate your feedback Please review our products on www blanco australia com ...
Страница 34: ...34 ...
Страница 36: ......