9
Always disconnect the appliance from the
electricity main before making any adjustments.
All seals must be replaced by the technician at
the end of any adjustments or regulations.
Our burners do not require primary air
adjustment.
a) Data Label
The Data Label is located on the underside of the
hotplate. A duplicate Data Label is supplied to adhere
in an accessible area next to the hotplate. This
hotplate is suitable for Natural Gas and Universal
LPG; ensure that the available gas supply matches
the Data Label.
b) Before Leaving
Check that there are no gas leaks, but do not use a
naked flame to detect gas leaks. Ignite all burners to
ensure correct operation of gas valves, burners,
ignition and if fitted, flame failure valves. Turn gas
taps to low flame position and observe stability of the
flame. When satisfied with the hotplate, please
instruct the user on the correct method of operation.
In case the appliance falls to operate correctly after
all checks have been carried out, refer to the
authorised service provider in your area.
7) TAPS
Our taps are suitable for all gas, are male conical
type.
“Reduced rate” adjustment
- Switch on the burner and turn the relative knob to
the “Reduced rate” position (small flame fig. 1).
- Remove knob “M” (fig. 13) of the tap, which is simply
pressed on to its rod.
- Insert a small screwdriver “D” into hole “C” (fig. 13)
and turn the throttle screw to the right or left until the
burner flame has been adequately regulated to the
“Reduced rate” position.
Check that the flame does not go out when the knob
is sharply switched from the “Full on” to the “Reduced
rate” position.
It is understood that only burners operating with
Natural gas should be subjected to the above
mentioned adjustments. The screw must be fully
locked when the burners operate with Liquid gas.
ADJUSTMENTS
FIG. 13