background image

TECHNICAL INFORMATION FOR

INSTALLATION PERSONNEL

This appliance shall be installed only  by authorised

personnel and in accordance with the manufacturer’s

installation instructions, local gas fitting regulations,

municipal codes, electrical wiring regulations,

AS/NZS 5601- Gas Installation and any other

statutory  regulations.  Ventilation  must  be  in

accordance with AS/NZS 5601- Gas Installation. In

general, the appliance should have adequate

ventilation for complete combustion of gas, proper

flueing and to maintain temperature of immediate

surroundings within safe limits. The wall and bench

surfaces must be capable of sustaining temperatures

of 75 °C.

All laminates, fixing adhesive and surfacing materials

should be certified suitable for this temperature.

Any adjoining wall surface situated within 200 mm from

the edge of any hob burner must be a suitable non-

combustible material for a height of 150 mm for the entire

length of the hob. Any combustible construction above the

hotplate must be at least 650 mm above the top of the

burner and no construction shall be within 450 mm above

the top of the burner. A minimum depth of 70 mm from the

top of the worktop surface must be provided for the

appliance.

3) INSTALLING THE HOT PLATE

Check that the appliance is in a good condition after

having removed the outer packaging and internal

wrappings from around the various loose parts. In

case of doubt, do not use the appliance and contact

qualified personnel.

Never leave the packaging materials (cardboard,

bags, polystyrene foam, nails, etc.) within

children’s reach since they could become

potential sources of danger.

The measurements of the opening made in the top

of the modular cabinet and into which the hot plate

will be installed are indicated in fig. 7.

Always comply with the measurements given for the

hole into wich the appliance will be recessed (see

fig. 7 and 8).

The  appliance  belongs  to  class  3  and  is

therefore  subject  to  all  the  provisions

established by the provisions governing such

appliances. 

7

INSTALLATION

FIG. 8

FIG. 7

IMPORTANT:  a  perfect  installation,

adjustment or transformation of the cook top

to use other gases requires a QUALIFIED

INSTALLER: a failure to follow this rule will

void the warranty.

Содержание BCG603WXFFC

Страница 1: ...functional and safety features on the products themselves If your cooktop requires service please contact the Blanco customer service centre COD 04077AX 27 10 2017 Dear Customer Thank you for purchasi...

Страница 2: ...children without supervision MAINTENANCE SCHEDULE Clean the cooktop surface after every use as specified within this manual Clean burner top and trivet at least once a week or after any spillage Gas...

Страница 3: ...ntrol knob 11 Burner n 5 control knob 12 Ultra rapid burner DCC AFB Wok 15 5 MJ h 12 6 MJ h MJ h 13 Burner n 12 control knob Attention this appliance has been manufactured for domestic use only Do not...

Страница 4: ...in thick metal WARNINGS Burners with flame failure device may only be ignited when the relative knob has been set to the Full on position large flame fig 1 Matches can be used to ignite the burners i...

Страница 5: ...y opening a window or by increasing the power of the mechanical exhausting system if installed Do not attempt to change the technical characteristics of the product because it can be dangerous If you...

Страница 6: ...n the burner head It must be steady The exact position of the pan support is established by the rounded corners which should be set towards the side edge of the hot plate Do not force the taps if they...

Страница 7: ...0 mm above the top of the burner and no construction shall be within 450 mm above the top of the burner Aminimum depth of 70 mm from the top of the worktop surface must be provided for the appliance 3...

Страница 8: ...set the plate into the hole made in the cabinet Fix the hob with the proper brackets S and fit the prominent part into the porthole H on the bottom turn the screw F until the bracket S stick on the to...

Страница 9: ...tion Unions compatible with the hose fittings must be used and all connections tested for gas leaks The gas supply connection point must be accessible with the appliance installed Natural Gas Natural...

Страница 10: ...d to the electricity main by a socket Fit a standard plug suited to the load indicated on the data label to the cable Fit the wires following figure n 12 taking care of respecting the following corres...

Страница 11: ...refer to the authorised service provider in your area 7 TAPS Our taps are suitable for all the gas they are male conical type at one way Reduced rate adjustment Switch on the burner and turn the relat...

Страница 12: ...m panel near the gas connection 12 Fit the new data label included in the gas conversion kit 9 NATURAL GAS TO U LPG CONVERSION PROCEDURE Appliance models Gas stainless steel hotplate models BCG603WXFF...

Страница 13: ...re regulating devices The envelope with the injectors and the labels can be included in the kit or at disposal to the authorized customer Service Centre For the sake of convenience the nominal rate ta...

Страница 14: ...s given in paragraph 6 FIG 16 H05 RR F Section 3 X 0 75 mm2 Gas hot plate If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person i n...

Страница 15: ...After Sales Service Centres and a qualified retail outlets The above data are printed on the data label put on the inferior part of the appliance and on the packing label The above informations give...

Страница 16: ...nths on any labour cost of service or repair SERVICE AREA The provision of service under Our Warranty is limited by the boundary territory area of the nearest service centre Travelling cost incurred f...