Blake Water Solutions MOD-420-BWS Скачать руководство пользователя страница 1

Operation & Installation Instructions

EQUIPMENT MODULES

Содержание MOD-420-BWS

Страница 1: ...Operation Installation Instructions EQUIPMENT MODULES ...

Страница 2: ...Table of Contents Emulator Module 1 Remote Alarm Module 2 4 20 mA Module 3 Solonoid Module 4 Water Quality Monitor Module 8 ...

Страница 3: ...rning the switch to its OFF toggle up position The device also can emulate the UV intensity reported by a UV sensor module Turning the right UV knob in the clockwise direction will increase the intensity while turning it counterclockwise will decrease the intensity Please note that to see all the capabilities of the sensor you will need to cycle the intensity through the range of 49 through 66 The...

Страница 4: ...ry contacts and can be used to connect the controller to a PLC based system an alarm buzzer or light or an OK light The Maximum contact rating is 30V 1A If your device draws more current please use the module to switch a relay with contacts rated for the device you wish to use Sensor IEP Installation IEP connection BWS5 BWS6 Series controllers BWS5 C 6 C Series controllers IEP connection IEP conne...

Страница 5: ...e IEP on the controller or into any other BLAKE module that contains an IEP sensor remote alarm solenoid module etc Connect LOOP Connections as follows Sensor IEP Installation IEP connection BWS5 BWS6 Series controllers BWS5 C 6 C Series controllers IEP connection IEP connection LOOP Specifications Power Supply Min 5 volts Max 30 volts Power Supply PLC or Data Logger 4 20 mA module MOD 420 BWS ...

Страница 6: ...f the solenoid cable has a plug attached remove the plug and strip the wires to a suitable length INSTALLATION Step 1 Make sure the solenoid valve cable is NOT plugged into the electrical outlet Insert the solenoid valve cable through the center hole of the middle strain relief Connect the three electrical wires to the terminal block that is marked SOLENOID see Fig 1 Connect the ground wire in the...

Страница 7: ...e Once all these connections have been made affix the male IEP plug of the solenoid module cable into the IEP port on the controller or any other available IEP port such as the UV sensor 4 20 mA module or remote alarm module It does not matter which IEP port any module is attached to as long as they are attached Figure 3 Solenoid Test Button OPERATION Step 1 Plug the controller into the power sour...

Страница 8: ...ently in the solenoid module incorporates three lights on the circuit board see Fig 7 When the solenoid is in the OPEN position a green light will appear on the circuit board beside the word OPEN When the valve is CLOSED a red light will appear on the circuit board beside the word CLOSED And when the solenoid is in an OVERRIDE position an amber light will appear on the circuit board beside the wor...

Страница 9: ...ailability and use of the emergency bypass feature may be in violation of the local state provincial codes If this is the case the bypass feature can easily be disabled by physically removing the bypass button To accomplish this carefully use a pair of needle nose pliers and physically remove the actual bypass button marked OVERRIDE from the circuit board Figure 10 SOLENOID FAILURE Screen OTHER FA...

Страница 10: ...e Display for additional Remote Display installation Installation Step 1 Power off the UV system controller Step 2 Plug the male plug of the Transmitter into the IEP Infinite Expandability Port on the controller or into any other module that contains an IEP sensor 4 20 mA module solenoid module etc and then restart the system Note 1 Step 3 To Receive the UV system controller s status on the Remote...

Страница 11: ...put controllers during the start up sequence NOTE 2 The Wireless Range can vary based on the installation environment objects walls and metal obstacles can interfere and degrade the wireless signal Best suited for residential applications Pairing an Additional Remote Display To pair an additional Remote Display to a currently installed Transmitter Step 1 Power ON the Additional Remote Display with...

Страница 12: ...Blake Equipment 4 New Park Rd East Windsor CT 06088 1 800 353 1100 Email bwsinfo blakeequip com www blakeequip com PN 910406 Version Date 06 2021 ...