pic. 8

Air FilTer

The supplied air filter must be used.
Failure to do so may result in irreparable damage 

and will void the warranty, Pic. 8
To install:

1. Carefully screw supplied air filter into the 

threaded hole on the top of the pump head.  

This only needs to be done up by hand.  Do not 
use tools to tighten air filter.

NOTE:  Do not OVER TIGHTEN as this may 
damage the air filter or cylinder head which will 
NOT be covered under warranty.

STArTiNg ANd SToppiNg 

yoUr Air compreSSor

pic. 9

NOTE:  Always ensure that you plug your air 

compressor into a standard 240V AC power point.  

Never use an extension cord as this can lead to a 
voltage drop which may cause power loss and over 

heating.  Use a longer air hose if you need to get 

closer to your work area.
Always start and stop the compressor using 

the ON/OFF button on the Pressure Switch 

(Pic. 1 Item 14 and 15 as well as  Pic. 9).  
Never use the power point switch to operate 
the compressor as this will cause damage and 

injury may occur. Damage caused by not using 
this button will not be covered by warranty.

To turn your air compressor oN;

Lift up the red ON / OFF button on top of the 

pressure switch

To turn your air compressor oFF;

Push down the red ON / OFF button on top of the 

pressure switch

pic. 9

Push button

 

down for off

Lift button

 

up for on

Содержание 180 Hi-Flow

Страница 1: ...02776 03 11 For service spare parts or product information please contact Smart Marketing Group Pty Ltd AUST 1300 660 457 N Z 0800 474 876...

Страница 2: ...un C bradder T nailer PAINTING Gravity feed spray gun Low pressure spray gun Touch up spray gun High pressure spray gun Section Page Contents 2 Suggested Applications 2 Introduction 3 Guarantee 3 4 Ge...

Страница 3: ...nd conditions below What is covered Manufacturing fault or defect How to claim under this warranty Call customer service phone number at the top Ensure you have the following Original purchase receipt...

Страница 4: ...made available if the request is made to our customer service team on the contact numbers listed below and proof of purchase is provided This is a repair only warranty you will need to take the air c...

Страница 5: ...r room when not in use Work Area Work areas and benches should be kept tidy Cluttered benches and work areas can cause accidents Floors should be kept clean and free from rubbish Special care should b...

Страница 6: ...handles clean dry and free from oil and grease Ensure that ventilation slots are kept clean and free from dust at all times Blocked ventilation slots or air filter can cause overheating and damage to...

Страница 7: ...OFF DO NOT use the power point switch to operate the air compressor as this will cause damage and injury may occur Any damage will not be covered under warranty Personal Safety Clothing Do not wear l...

Страница 8: ...that the air compressor is disconnected from the mains supply when not in use before servicing lubricating making changes and when changing attachments such as air hoses tools Always use the correct...

Страница 9: ...ubber stoppers 9 Tank pressure gauge large 10 Outlet pressure gauge small 11 Front handle Large and small 12 Air tap Air outlet 13 Outlet pressure regulator 14 Pressure switch 15 On Off button red col...

Страница 10: ...20cm hold for about 1 minute and place back on ground Look at the sight glass and ensure the oil is above the red dot on the sight glass as per the OIL LEVEL GAUGE label see Pic 3 and Pic 4 To add oil...

Страница 11: ...ough the bracket and replace the washer 3 Tighten the nut Pic 5 Wheels 1 Insert a bolt through the wheel 2 Push through the tank wheel bracket 3 Tighten the nut Pic 6 Handle 1 Loosen bolts in tubes we...

Страница 12: ...a standard 240V AC power point Never use an extension cord as this can lead to a voltage drop which may cause power loss and over heating Use a longer air hose if you need to get closer to your work a...

Страница 13: ...Transport plug removed and discarded see Pic 2 page 10 2 Oil breather fitted see Pic 2 page 10 3 Oil level CORRECT top of red dot Please refer to diagram Pic 4 page 10 4 Air tap CLOSED 5 Drain tap ope...

Страница 14: ...lean your air hose and air tools 5 Store your air hose and air tools in a secure well ventilated cabinet 6 Slowly open the tank drain tap see page 16 This allows excess air and moisture water to vent...

Страница 15: ...with the tool manufacturer if unsure Safety Valve Pic 12 NOTE When checking the safety valve ALWAYS wear safety glasses To check the operation of the safety valve the air tank will need to be full Gen...

Страница 16: ...l the drain tap before starting the compressor Pic 13 Air Tap Pic 13 The air tap will need to be opened to allow the air to flow to the attached air tool To open air tap rotate the handle so that it l...

Страница 17: ...0800 474 876 Pic 15 Maintenance Daily Before use 1 Seal the tank drain tap see page 16 Pic 14 2 Check the oil level see page 10 Pic 4 3 Check safety valve operation see page 15 Pic 12 After use 1 Open...

Страница 18: ...Tap 1 95 BRC120OPRD 39 Outlet Tap 2 95 BRC95OT 40 Unloading Tube Nut 2 95 BRC95UT 41 Unloading Tube 1 95 BRC95UT 42 Pressure Gauge Large 1 95 BRC95TPG Part Description Qty SMG Part No 43 Pressure Gau...

Страница 19: ...nk Size 40 L Suggested Applications You may use most air tools with this compressor Some examples of tools are CLEANING Engine cleaning gun Sandblaster kit Air blow gun Abrasion kit TOOLS Air hammer A...