BLACKMER LGLH2A Скачать руководство пользователя страница 3

 

501-J00    Page 3/12 

GENERAL INSTALLATION AND OPERATION 

 

NOTICE: 

Blackmer pumps must only be installed in systems 
designed by qualified engineering personnel.  System 
design must conform with all applicable regulations and 
codes and provide warning of all system hazards. 

 

NOTICE: 

This pump shall be installed in accordance with the 
requirements of NFPA 58 all applicable local, state and 
national regulations. 

 
 

WELDED CONNECTIONS 

NOTICE: 

Pump with welded connections contain three non-
metallic o-ring seals that will be damaged if welding is 
done with these o-rings installed.  

Prior to welding the piping, remove the O-rings from under the 
inlet flange, outlet flange and relief valve cover as indicated in 
Figure 1. 

Reinstall the inlet and outlet flanges. Weld the piping to the 
the inlet and outlet flanges. After the welding is complete, 
reinstall the O-rings.

 

 

 

Figure 1 

 
 
PRE-INSTALLATION CLEANING 

NOTICE: 

New pumps contain residual test fluid and rust inhibitor.  
If necessary, flush pump prior to use. 

Foreign matter entering the pump WILL cause extensive 
damage.  The supply tank and intake piping MUST be 
cleaned and flushed prior to pump installation and operation. 

LOCATION AND PIPING 

Pump life and performance will be significantly reduced when 
installed in an improperly designed system. Before starting 
the layout and installation of the piping system, review the 
following suggestions: 

 

1.  Locate the pump as near as possible to the source of 

supply to avoid excessive inlet pipe friction. 

2.  The inlet piping and fittings should be at least as large as 

the intake port on the pump. It should slope downward to 
the pump, and should not contain any upward loops. 
Minimize the number of intake line fittings and eliminate 
restrictions such as sharp bends; globe valves, 
unnecessary elbows, and undersized strainers. 

3.  A strainer must be installed in the inlet line to protect the 

pump from foreign matter. The strainer should be located 
at least 24" (0.6m) from the pump, and have a net open 
area of at least four times the area of the intake piping. 
Strainers must be cleaned regularly to avoid pump 
starvation. 

4.  The intake and discharge piping system must be free of 

all leaks. 

5.  Expansion joints, placed at least 36" (0.9m) from the 

pump, will compensate for expansion and contraction of 
the pipes. Contact the flexible connector/hose 
manufacturer for required maintenance/care and design 
assistance in their use. 

6. 

ALL piping and fittings MUST be properly supported to 
prevent any piping loads from being placed on the pump.

 

7.  Check alignment of pipes to pump to avoid strains which 

might later cause misalignment.  See Figure 2.  Unbolt 
flanges or break union joints.  Pipes should not spring 
away or drop down.  After pump has been in operation 
for a week or two, completely recheck alignment. 

 

Figure 2 

8.  Install pressure gauges in the NPT ports provided in the 

pump casing to check pump performance at start up. 

9.  The use of a 1.5” or 2” vapor return line will speed up 

delivery by preventing pressure build up at the receiving 
tank and pressure reduction in the supply tank. 

10.  Keeping the liquefied gas systems full of liquid, even 

when idle, will keep the O-rings from changing shape, 
shrinking or super cooling. Evaporation of liquefied gas 
leaves an abrasive powder on the surface which can 
cause wear to the pump, meter, and seals. 

 

Содержание LGLH2A

Страница 1: ...ww blackmer com or by contacting Blackmer Customer Service SAFETY DATA This is a SAFETY ALERT SYMBOL When you see this symbol on the product or in the manual look for one of the following signal words...

Страница 2: ...property damage If pumping hazardous or toxic fluids system must be flushed and decontaminated inside and out prior to performing service or maintenance Hazardous or toxic fluids can cause serious in...

Страница 3: ...ke port on the pump It should slope downward to the pump and should not contain any upward loops Minimize the number of intake line fittings and eliminate restrictions such as sharp bends globe valves...

Страница 4: ...l attached components Never start a pump when it is rotating in the reverse rotation as the added starting torque can damage the pump and related equipment PUMP ROTATION NOTICE Confirm correct pump ro...

Страница 5: ...crews 152C G 5 Measure the span length as shown in Figure 6 6 Adjust the motor base 183 and apply a specified force refer to Table 1 against the belt at the center of the span so that the belt is defl...

Страница 6: ...ssure can cause personal injury or property damage Operation without guards in place can cause serious personal injury major property damage or death Do not operate without guard in place TRUCK MOUNTE...

Страница 7: ...is a Lever Operated Pull the control knob all the way out Manually check the lever under the truck to see that it is in the completely OPEN position b Discharge Pressure Operated Keep the discharge l...

Страница 8: ...cause serious personal injury or property damage Hazardous or toxic fluids can cause serious injury NOTICE Maintenance shall be performed by qualified technicians only following the appropriate proced...

Страница 9: ...aged lockwasher tang and rotate the locknut 24A counterclockwise to remove it from the shaft b Slide the lockwasher 24B off the shaft Inspect the lockwasher for damage and replace as required c Repeat...

Страница 10: ...pump with the seal cavity facing outward and the disc relief hole located as shown in Figure 9 7 Install a new head O ring 72 in the groove on the inside face of the head 20 Lay the O ring flat and st...

Страница 11: ...y hand g To check adjustment grasp the nut and washer with fingers and rotate back and forth If this cannot be done one or both locknuts are too tight and should be alternately loosened one stop at a...

Страница 12: ...ent shaft or drive coupling misaligned 9 Excessively worn rotor 10 Malfunctioning valve in the system 11 Relief valve setting too low 12 Liner installed backwards 13 Damaged vanes see following catego...