501-F00 page 2/12
SAFETY DATA
Hazardous
machinery can
cause serious
personal injury.
FAILURE TO DISCONNNECT AND
LOCKOUT ELECTRICAL POWER OR
ENGINE DRIVE BEFORE ATTEMPTING
MAINTENANCE CAN CAUSE SEVERE
PERSONAL INJURY OR DEATH
Hazardous voltage.
Can shock, burn or
cause death.
FAILURE TO DISCONNECT AND
LOCKOUT ELECTRICAL POWER
BEFORE ATTEMPTING MAINTENANCE
CAN CAUSE SHOCK, BURNS OR
DEATH
Hazardous pressure
can cause serious
personal injury or
property damage
DISCONNECTING FLUID OR PRESSURE
CONTAINMENT COMPONENTS DURING
PUMP OPERATION CAN CAUSE
SERIOUS PERSONAL INJURY OR
PROPERTY DAMAGE.
Hazardous pressure
can cause serious
personal injury or
property damage
FAILURE TO RELIEVE SYSTEM
PRESSURE PRIOR TO PERFORMING
PUMP SERVICE CAN CAUSE SERIOUS
PERSONAL INJURY OR PROPERTY
DAMAGE.
SYSTEMS WITH METERS
WILL STILL BE PRESSURIZED EVEN
AFTER THE HOSE IS EMPTIED
Hazardous or toxic
fluids can cause
serious injury.
IF PUMPING HAZARDOUS OR TOXIC
FLUIDS, SYSTEM MUST BE FLUSHED
AND DECONTAMINATED, INSIDE AND
OUT, PRIOR TO PERFORMING SERVICE
OR MAINTENANCE
Do not operate
without guard
in place
OPERATION WITHOUT GUARDS IN
PLACE CAN CAUSE SERIOUS
PERSONAL INJURY, MAJOR
PROPERTY DAMAGE, OR DEATH.
PUMP DATA
PUMP IDENTIFICATION
A pump Identification tag, containing the pump serial number, I.D. number, and model designation, is attached to each pump. It is
recommended that the data from this tag be recorded and filed for future reference. If replacement parts are needed, or if
information pertaining to the pump is required, this data must be furnished to a Blackmer representative.
TECHNICAL DATA
Maximum Pump Speed
1,750 RPM
Maximum Operating Temperature
240°F
(115°C)
Maximum Differential Pressure
125 psi
(8.6 Bar)
Maximum Working Pressure
350 psi
(24.1 Bar)
•
Technical Data is for standard materials of
construction. Consult Blackmer Material Specs for
optional materials of construction.
•
These pumps are listed by Underwriters’ Laboratories
for liquefied petroleum gas and NH
3
service.
INITIAL PUMP START UP INFORMATION
Model No.: ____________________________________
Serial No.: ____________________________________
ID No.: _______________________________________
Date of Installation: _____________________________
Inlet Gauge Reading: ____________________________
Discharge Gauge Reading: _______________________
Flow Rate: _____________________________________
Содержание LDF1A