©2022 Blackline Safety Corp
G7 Dock Technical User Manual
|
8
Rev. 11
2022-09-26
2
SET UP
2.1
GAS INLET CONFIGURATION
The back of G7 Dock is equipped with a Gas out exhaust and four gas inlets with
quick-connects. The inlets are pre-programmed for you.
When looking at the back of G7 Dock, the Gas out exhaust is the connector on the far-left
side of the dock. It is used to transfer calibration gas to a safe exhaust location.
NOTE:
You should never plug gas into the Gas out exhaust.
The next three inlets (to the right of the Gas out exhaust) are configured to support your
selected gases and gas mixtures. The table below shows an example of a configuration with
and without Chlorine (Cl
2
). Your configuration may be different depending on the gases
configured in Blackline Live for your site.
NOTE:
For G7 Docks with serial numbers beginning with 8247 and higher, inlet 1 has been
optimized for use with reactive gases such as Cl
2
. If you are configuring G7 Dock for use with
Cl
2
, you must use inlet 1 for the Cl
2
.