34
1.877.877.2269
BLACKBOX.COM
NEED HELP?
LEAVE THE TECH TO US
LIVE 24/7
TECHNICAL
SUPPORT
1.877.877.2269
CHAPTER 7: MAINTENANCE
FILTER MAINTENANCE
The system filter is an integral part of the Radian 6-Slot Chassis and needs to be maintained correctly. Failure to maintain the filter
can result in the system overheating and causing it to fail. In normal operating conditions, the filter should be removed and cleaned
every 3 months. However, this 3-month period is a guide only and it can be increased to every 6 months or decreased to one month
depending on the levels of dust in the environment the system is operating in.
We recommend that you check the condition of the filter at regular intervals.
The filter can be removed and cleaned whilst the system is in operation, system shut-down is not necessary.
NOTE: Failure to maintain the system filter could result in damage to your system and invalidate the warranty.
REMOVE THE FILTER
The system filter is housed within the mesh cover on the front panel. Gently pull the mesh cover away from the front of the main
unit and remove the filter from within.
Remove the filter from the rear of the
mesh cover to clean.
FIGURE 7-1. REMOVING THE FILTER
Shake the filter to remove any dust particles, this should not be done in close proximity to the system to avoid dust ingress. Ideally,
the filter should be cleaned using a vacuum cleaner.
NOTE: Never immerse the filter in water or any other cleaning liquid.