63
CHAPTER 6: Cable Test Descriptions
6.13.2 V
IEWING A
G
RAPH OF
P
OWER
S
UM
NEXT R
ESULTS
To view a graph of the Power Sum NEXT test results:
1. From the detail or Summary Results screen, press GRAPH (F2).
2. Press PAIR (F1) to display the results for a different wire pair. Press
SEND (F2) to send the results to the remote unit.
3. Press the arrow keys to move the cursor to a new point on the graph.
The test result at the selected point is displayed below the graph.
4. Press Print (F4) to send a comma-separated variable (CSV) listing of the
results to the serial port. This outputs a complete listing of all Power
Sum NEXT measurements for all pairs.
5. Press SUMMARY (F3) or ESC to return to the Summary screen.
NOTE
The test result displayed on the graph is the worst value found within
1-MHz frequency increments for Category 5 and ISO Class D testing. All
test results are available and can be output from the SCAN-LAN Vt.
6.14 Cable Grading
Cable grading refers to the performance grading of cable based on the
NEXT performance relative to the test limit. A higher-grade cable exceeds
the test limit by a greater margin.
PAIR
SEND
SUMMARY
F1
F2
F3
F4
1
20
30
40
50
60
1,2
100
43.0dB
@
67.3MHz
32.1
Test Result
Test Limit
Cursor