Page 15 — English
Normal maintenance, replacement or repair of emission con-
trol devices and systems may be performed by any qualified
repair establishment or individual with original or equivalent
parts. Warranty and recall repairs must be performed by an
authorized service center; please contact customer service
for assistance.
WARNING:
Before inspecting, cleaning or servicing the machine, shut
off engine, wait for all moving parts to stop, and discon-
nect spark plug wire and move it away from spark plug.
Allow 30 minutes of cool down time before performing
any maintenance. Failure to follow these instructions
can result in serious personal injury or property damage.
WARNING:
When servicing, use only recommended or equivalent
replacement parts. Use of any other parts can create a
hazard or cause product damage.
WARNING:
DO NOT tamper with, adjust, or modify the carbon mon-
oxide (CO) sensor module on your generator. Failure to
follow these instructions can cause the monitor to mal-
function which can result in death or serious personal
injury.
NOTICE:
Periodically inspect the entire product for damaged,
missing, or loose parts such as screws, nuts, bolts, caps,
etc. Tighten securely all fasteners and caps and do not
operate this product until all missing or damaged parts
are replaced. Please contact customer service or a quali-
fied service center for assistance.
GENERAL MAINTENANCE
Keep the generator in a clean and dry environment where it
is not exposed to dust, dirt, moisture, or corrosive vapors.
Do not allow the cooling air slots in the generator to become
clogged with foreign material such as leaves, etc.
Do not use a garden hose to clean the generator. Water en-
tering the fuel system or other internal parts of the unit can
cause problems that will decrease the life of the generator.
To clean the unit:
Use a soft bristle brush and/or vacuum cleaner to loosen
and remove dirt and debris.
Clean air vents with low pressure air that does not exceed
25 psi.
Wipe the exterior surfaces of the generator with a damp
cloth.
CHECKING/CLEANING AIR FILTER
See Figure 14.
For proper performance and long life, keep air filter clean.
Rotate knob counterclockwise to release. Remove cover
and set aside.
OPERATION
MOVING THE GENERATOR
See Figure 12.
Turn off the generator.
Raise the handle to the up position.
Disconnect any equipment that is plugged into the gen-
erator.
Turn the fuel valve to the
OFF
position.
Allow 30 minutes of “cool down” time before storing the
machine.
With your foot on the rear of the frame, tilt the machine
toward you until it balances on the wheels, then roll the
machine to the desired location.
LIFTING THE GENERATOR
See Figure 13.
Turn off the generator.
Fold the handle to the down position. Never lift or carry
this product using the handle.
NOTE:
This tool is heavy and requires several people to
lift. To avoid back injury, keep your knees bent and lift
with your legs, not your back, and get help when needed.
HIGH ALTITUDE OPERATION
Your engine is configured for operation below 3,000 feet
altitude at the factory. Your engine must be reconfigured for
operation above 3,000 feet altitude. Operating the engine
with the wrong engine configuration at a given altitude may
increase its emissions, decrease fuel efficiency, degrade per-
formance, and cause irreversible damage. Engines configured
for high altitude operation cannot be operated in standard
altitude conditions. A qualified service center should ensure
that your engine is properly configured for your location.
MAINTENANCE
Содержание BM903622
Страница 25: ...Page 21 English NOTES ...
Страница 47: ...Page 21 English NOTES ...