Black Max BM903000 Скачать руководство пользователя страница 7

Page 3  — English

IMPORTANT SAFETy INSTRUCTIONS

DANGER:

Carbon Monoxide.

 Using a generator indoors CAN KILL 

YOU IN MINUTES.
Generator exhaust contains high levels of carbon mon-
oxide (CO), a poisonous gas you cannot see or smell. If 
you can smell the generator exhaust, you are breathing 
CO. But even if you cannot smell the exhaust, you could 
be breathing CO.

 

Never use a generator inside homes, garages, crawl-
spaces, or other partly enclosed areas. Deadly levels 
of carbon monoxide can build up in these areas. Us-
ing a fan or opening windows and doors does NOT 
supply enough fresh air.

 

ONLY use a generator outdoors and far away from 
open windows, doors, and vents. These openings 
can pull in generator exhaust.

Even when you use a generator correctly, CO may 
leak into the home. ALWAYS use a battery-powered or 
battery-backup CO alarm in the home.
If you start to feel sick, dizzy, or weak after the generator 
has been running, move to fresh air RIGHT AWAY. See a 
doctor. You could have carbon monoxide poisoning.

WARNING:

Read and understand all instructions.

 Failure to follow 

all instructions listed below could result in electrocution, 
fire, and/or carbon monoxide poisoning, which can cause 
death or serious injury.

DANGER:

National Electric Code requires generator to be grounded 
to an approved earth ground. Before using the ground ter-
minal, consult a qualified electrician, electrical inspector, 
or local agency having jurisdiction for local codes or or-
dinances that apply to the intended use of the  generator.

SAVE THESE INSTRUCTIONS

This manual contains important instructions that should be 
followed during installation and maintenance of the generator.

 

Do not connect to a building’s electrical system unless 
the generator and transfer switch have been properly 
installed and the electrical output has been verified by 
a qualified electrician. The connection must isolate the 

generator power from utility power and must comply with 
all applicable laws and electrical codes.

 

Do not allow children or untrained individuals to use this 
unit.

 

Do not start or operate the engine in a confined space, 
building, near open windows, or in other unventilated space 
where dangerous carbon monoxide fumes can collect. 
Carbon monoxide, a colorless, odorless, and extremely 
dangerous gas, can cause unconsciousness or death.

 

Keep all bystanders, children, and pets at least 10 feet 
away.  

 

Wear sturdy and dry shoes or boots. Do not operate while 
barefoot.

 

Do not operate generator when you are tired or under the 
influence of drugs, alcohol, or medication.

 

Keep all parts of your body away from any moving parts 
and all hot surfaces of the unit.

 

Do not touch bare wire or receptacles.

 

Do not use generator with electrical cords which are worn, 
frayed, bare, or otherwise damaged.

 

Before storing, allow the engine to cool and drain fuel 
from the unit.

 

Do not operate or store the generator in rain, snow, or 
wet weather.

 

Store the generator in a well-ventilated area with the fuel 
tank empty. Fuel should not be stored near the  generator.

 

Empty fuel tank, close fuel valve, and restrain the unit 
from moving before transporting in a vehicle.

 

Allow engine to cool for five minutes before refueling.

 

To reduce the risk of fire and burn injury, handle fuel with 
care. It is highly flammable.

 

Do not smoke while handling fuel.

 

Store fuel in a container approved for gasoline.

 

Position the unit on level ground, stop engine, and allow 
to cool before refueling.

 

Loosen fuel cap slowly to release pressure and to keep 
fuel from escaping around the cap.

 

Tighten the fuel cap securely after refueling.

 

Wipe spilled fuel from the unit.

 

Never attempt to burn off spilled fuel under any circum-
stances.

 

Generators vibrate in normal use. During and after the 
use of the generator, inspect the generator as well as 
extension cords and power supply cords connected to 
it for damage resulting from vibration. Have damaged 
items repaired or replaced as necessary. Do not use plugs 
or cords that show signs of damage such as broken or 
cracked insulation or damaged blades.

 

For power outages, permanently installed stationary gen-
erators are better suited for providing back-up power to 
the home. Even a properly connected portable generator 
can become overloaded. This may result in overheating 
or stressing the generator components, possibly leading 
to generator failure.

Содержание BM903000

Страница 1: ...a registrar su producto de BlackMax por favor visita http register blackmaxtools com NOTICE AVISO Do not use E15 or E85 fuel or fuel containing greater than 10 ethanol in this product It is a violatio...

Страница 2: ...See this fold out section for all of the figures referenced in the operator s manual Consulte esta secci n desplegable para ver todas las figuras a las que se hace referencia en el manual del operado...

Страница 3: ...20 voltios recept culos giratorios de 25 A G 120 volt RV 30 amp receptacle recept culo RV de 30 A y 120 voltios H Oil cap dipstick tapa de relleno de aceite varilla medidora de aceite I Oil drain plug...

Страница 4: ...A Engine switch interruptor del motor B Off apagado C On encindido A Pull choke to the open START position coloque del anegador en la posici n START arranque B Push choke to the closed RUN position t...

Страница 5: ...la de combustible A Spark plug buj a B Spark plug cap tapa de la buj a a b c Fig 15 B A A Fuel line conducto de combustible B Fuel filter filtro de combustible A C B A E F G D A Exhaust deflector defl...

Страница 6: ...e ground source TheNationalElectricCodecontainsseveralpracticalwaysinwhichtoestablishagood groundsource Ifasteelorironrodisused itshouldbeatleast5 8in diameter andifa nonferrousrodisused itshouldbeatl...

Страница 7: ...or operate the engine in a confined space building nearopenwindows orinotherunventilatedspace where dangerous carbon monoxide fumes can collect Carbon monoxide a colorless odorless and extremely dange...

Страница 8: ...ing Place the generator on a flat stable surface with a slope of no more than 4 Operate in a well ventilated well lit area isolated from working areas to avoid noise interference Operating the generat...

Страница 9: ...use severe burns or death Hot Surface To reduce the risk of injury or damage avoid contact with any hot surface Lifting Hazard To reduce the risk of serious injury avoid attempting to lift the generat...

Страница 10: ...ia nin a la nieve No opere con manos o pies h medos Exhaust contains poisonous carbon monoxide gas that can cause unconsciousness or DEATH Operate in well ventilated outdoor areas away from open windo...

Страница 11: ...CHECK LUBRICANT 940828004 02 El uso de este equipo puede producir chispas propensas a iniciar incendios cerca de vegetaci n seca Es posible que se necesite un parachis pas El operador debe ponerse en...

Страница 12: ...to estimate the watts required to start electric motors however if an electric motor fails to start or reach running speed turn off the appliance or tool immediately to avoid equipment damage Always...

Страница 13: ...e care when adding electrical loads to the generator There should be nothing connected to the generator outlets before starting its engine The correct and safe way to manage generator power is to sequ...

Страница 14: ...cal shock Consult with a local electrician for grounding requirements in your area OFF switch The off switch is located on the control panel To turn the engine off turn the switch to the OFF position...

Страница 15: ...or assistance WARNING If any parts are damaged or missing do not operate this product until the parts are replaced Use of this product with damaged or missing parts could result in serious personal in...

Страница 16: ...n result in serious personal injury APPLICATIONS This generator is designed to supply electrical power for operating compatible electrical lighting appliances tools and motor loads BEFORE OPERATING th...

Страница 17: ...face If the engine is hot let the generator cool before adding gas ALWAYS fill the fuel tank outdoors with the machine turned off Put the engine switch in the OFF position Remove the fuel cap Fill the...

Страница 18: ...he filter and filter cover Press the latch tabs to secure NOTE Do not run the generator without the air filter Rapid engine wear will result maintenance changing engine lubricant See Figure 9 Remove t...

Страница 19: ...k Remove the fuel line from the petcock by squeezing the ends of the retaining clip and sliding the fuel line off Install one end of a drain line over the petcock and place the other end in a fuel con...

Страница 20: ...ator is used in dusty areas When generator has exceeded the maximum figures specified in the table maintenance should still be cycled according to the intervals of time or hours stated herein storage...

Страница 21: ...s contact your nearest authorized service center AC receptacle does not work Circuit breaker is off Item plugged in is defective Turn ON the AC circuit breaker Try a different item Generator makes a s...

Страница 22: ...neglect alteration modification the effects of corrosion erosion normal wear and tear or repairs by other than the Company or its authorized service representative Warranty is voided if the customer...

Страница 23: ...por este generador deben conectarse apropiadamente a tierra mediante el uso de un tercer alambre o tener un dise o con doble aislamiento Se recomienda 1 Usar dispositivos el ctricos con clavija de tre...

Страница 24: ...e peligroso puede causar la p rdida de la conciencia o la muerte Mantenga a todos los circunstantes ni os y animales por lo menos a 3 m 10 pies de distancia Use botas o zapatos robustos y secos No uti...

Страница 25: ...o Si se utiliza el generador en condiciones h medas puede causarse una electrocuci n Mantenga seca la unidad Mantenga el generador a una distancia m nima de 0 9 m 3 pies de todo tipo de material combu...

Страница 26: ...ueden causar quemaduras graves e incluso la muerte Superficie caliente Para reducir el riesgo de lesiones corporales o da os materiales evite tocar toda superficie caliente Peligro al levantar Para re...

Страница 27: ...ential source of electric shock Do not expose to moisture rain or snow Do not operate with wet hands or feet El generador es una fuente de descarga el ctrica No lo exponga a humedad la lluvia nin a la...

Страница 28: ...cts at least 3 feet away from this machine Heat from Muffler and Exhaust gases can ignite combustible objects Riesgo de incendio Mantener todos los objetos a una distancia m nima de 91 4 cm 3 pies de...

Страница 29: ...seis veces su corriente de operaci n Esta tabla puede emplearse para estimar la potencia necesaria en vatios para arrancar los motores el ctricos no obstante si un motor el ctrico no arranca o no alca...

Страница 30: ...delgeneradorconsiste enagregarlas cargasdemanera secuencial de la manera siguiente 1 Sinequiposconectadosalgenerador pongaenmarchaelmotor de la manera que se describe posteriormente en este manual 2 E...

Страница 31: ...ca donde se encuentre usted INTERRUPTOR DEL MOTOR El interruptor del motor est situado en el panel de control Para apagar el motor coloque el interruptor en la posici n OFF apagado tapa de relleno de...

Страница 32: ...a adas o faltantes le suplicamos llamar al 1 800 726 5760 donde le brindaremos asistencia ADVERTENCIA Si falta o est da ada alguna pieza no utilice este producto sin haber reemplazado la pieza Usar es...

Страница 33: ...las reas cubierta con rayas entrecruzadas de la varilla medidora Si est bajo el nivel abastezca de lubricante el motor hasta que el nivel del fluido alcance la parte superior de la varilla Vuelva a c...

Страница 34: ...ecer de gasolina la generador aseg rese de que la unidad est asentada en una superficie horizonal nivelada Si est caliente el motor permita que se enfr e la generador antes de reabastecerla de gasolin...

Страница 35: ...perficie dura para quitar el polvo y los desechos Puede soplar airecomprimidoatrav sdelfiltrodesdeelladolimpiodelmismo NOTA No utilice un cepillo para quitar el polvo Esto introducir a el polvo en las...

Страница 36: ...e purga Retire el conducto de combustible de la llave de purga para ello apriete los extremos del sujetador de retenci n y separe Mantenimiento el conducto Instale un extremo del conducto de drenaje e...

Страница 37: ...ia de mantenimiento debe ser mayor si se el generador se usa en zonas de mucho polvo Si el generador ha sobrepasado los valores m ximos especificados en el cuadro aun debe seguirse el programa de mant...

Страница 38: ...e y el carburador Reabastezcadegasolinafrescalaunidad Si el problema contin a comun quese con un centro de servicio autorizado No funciona el recept culo de corriente alterna El disyuntor est en apaga...

Страница 39: ...modificaci n los efectos de la corrosi n la erosi n el desgaste normal o las reparaciones realizadas por personas ajenas a la Compa a o a sus representantes de servicio autorizados La garant a queda a...

Страница 40: ...er Be sure to provide all relevant information when you call or visit For the loca tion of the authorized service dealer nearest you please call 1 800 726 5760 REPAIR PARTS The model number of this pr...