Designed and manufactured in New Zealand

Black Diamond Technologies

USER MANUAL

Содержание HYDROBOX 2

Страница 1: ...Designed and manufactured in New Zealand Black Diamond Technologies USER MANUAL...

Страница 2: ...Page 2 Modes Page 2 Controller Control Panel Page 3 Power Button Page 3 Operation Display Screens Pages 4 7 Trouble Shooting Page 8 Fault Codes and Descriptions Page 9 Important Information Page 10 W...

Страница 3: ...l Low standby power consumption Internal power usage meter Battery backup internal clock Audible Alarm in following situations Over current Insufficient heating Over temperature No water Water leakage...

Страница 4: ...d day since last being active This ensures the tank water is safe even after long periods of not being used Modes The Black Diamond Hydrobox 2 can be set in one of three modes Normal Norm 40 C return...

Страница 5: ...the user or it will automatically power on from Standby when The power is initially connected or recovers from a power outage The water tank temperature drops by 20 C The power turned on by a traditi...

Страница 6: ...reen and the green power LED will illuminate see Fig 1 to indicate the unit is on If the green power LED is flashing this indicates one or more of the 7 timers is set When powered on the set temperatu...

Страница 7: ...st Down or Up to the correct day Finally press to finish the Time Date setting Summer Winter Time Set Screen To set the daylight saving start and stop days please use the following steps Scroll to the...

Страница 8: ...selected To do so press the On Off description will begin flashing to indicate it is ready to be changed Use Down or Up to adjust If an On Off or On Timer is required press Down or Up until On is ind...

Страница 9: ...re Probes Screen Temp In 22 Temp In 22 Temp In 22 c Out 22 c Out 22 c Out 22 c c c Set Temp 62 Set Temp 62 Set Temp 62 c c c Water Pump Speed Screen H2O Pump Speed 0 H2O Pump Speed 0 H2O Pump Speed 0...

Страница 10: ...inspected WARNING To avoid running out of hot water the system is designed to ensure you have a minimum of half a tank of hot water before it starts the heating process If your household has high dem...

Страница 11: ...for defrost FLT13 IA too high 2 Yes Yes Call for service Indoor compressor fault FLT14 R134A discharge temp too high 90 0 2 Yes Yes Call for service Indoor compressor over heated refer to note 1 FLT1...

Страница 12: ...r is taken from the normal water tank element source For more details please refer to the installation manual IMPORTANT INFORMATION The unit should not be installed relocated disassembled altered or r...

Страница 13: ...must be insulated SPECIFICATIONS Heating Capacity Rated kW 3 4 Min Max kW 0 9 4 5 Input Rated kW 0 82 Min Max kW 0 004 1 40 Sound Level Outdoor SPL dBA 49 Power Supply Powered from indoor unit 240V Si...

Страница 14: ...f refrigerant leaks A halide torch or any other detector using a naked flame shall not be used The following leak detection methods are deemed acceptable for all refrigerant systems Electronic leak de...

Страница 15: ...he recovery of refrigerant Cylinders shall be complete with pressure relief valve and associated shut off valves in good working order Empty recovery cylinders are evacuated and if possible cooled bef...

Страница 16: ...PRINTED NOVEMBER 2021...