4. Set up instructions 

 

Read the entire important safety information section at the beginning of this manual 

including all text under subheadings therein before set up or use of this product. 

 

To prevent serious injury from accidental starting: Turn the power switch of 

the equipment to its “OFF” position, wait for the engine to cool before assembling or making any 
adjustments to the equipment. 

 

To prevent serious injury: Operate only with proper spark arrestor installed.

 

Operation of this equipment may create sparks that can start fires around dry vegetation. A spark 
arrestor may be required. The operator should contact local fire agencies for laws or regulations 
relating to fire prevention requirements.

 

Note: 

For additional information regarding the parts listed in the following pages, refer to the Assembly 

Diagram near the end of this manual.

 

 

A. Location

 

1. The Generator must be installed outdoors where ventilation is readily available. 

2. Install the Generator so that the air inlets and outlets are not blocked by obstructions such as bushes, 

trees, or snow drifts. Locating it in the path of heavy winds or snowdrifts may require the placement of 

5

a barrier for protection. The air inlet should face the prevailing wind direction. 

3. Install the Generator on a concrete slab or other area where water can not reach it. 

4. Generator placement should allow four feet of access on all sides for maintenance. 

5. Place the Generator as close as possible to the electrical tools and equipment being powered to 

reduce the length of extension cords. 

B. Grounding

 

1.  Connect a #12 AWG grounding wire (not included) from the Grounding Point on the Generator to a 

grounding rod (not included) that has been driven at least 24 inches into the ground. The grounding rod 
must be a copper or brass rod which can adequately ground the Generator. Only a trained and 
licensed electrician should perform this procedure. 

 

grounding point

2. Electrical and other permits may be required for the installation of emergency power systems. 

Investigate local building and electrical codes before installing this unit. Installation must be completed 
by a licensed contractor. 

 

Содержание 213823

Страница 1: ...with the user s manual could result in personal injury and or property damage Retain the user s manual for future Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon m...

Страница 2: ...EOCEDURE 7 TO START THE ENGINE 7 BREAK IN PERIOD B EQUIPMENT OPERATION TO POWER TOOLS AND EQUIPMENT 6 TECHNICAL SPECIFICATION 7 SERVICING A MAINTENANCE PROCEDURES ENGINE OIL CHANGE AIR FILTER ELEMENT...

Страница 3: ...ution are factors which cannot be built into this product but must be supplied by the operator Save these instructions A Set up precautions 1 Diesel fuel and fumes are flammable and potentially explos...

Страница 4: ...pment engine and surrounding area clean at all times 14 Use the equipment accessories etc in accordance with these instructions and in the manner intended for the particular type of equipment taking i...

Страница 5: ...ace such as a metal deck 12 Do not connect generator directly into a home s electrical lines Do not plug a generator into an outlet in the home Connecting a generator directly to a utility power suppl...

Страница 6: ...3 Controls Engine Switch Power Indicator 120V Receptacles 120V 240V receptacle 12V 8 3A DC receptacle 4 Voltage Meter Circuit Breaker Fuse Cover...

Страница 7: ...hat the air inlets and outlets are not blocked by obstructions such as bushes trees or snow drifts Locating it in the path of heavy winds or snowdrifts may require the placement of 5 a barrier for pro...

Страница 8: ...l the Fuel Tank first wipe off the Fuel Tank Cap and the surrounding area 3 Unscrew and remove the Fuel Tank Cap 4 Fill the Fuel Tank to about 1 inch under the fill neck of the tank with 2 diesel 5 Th...

Страница 9: ...e off 1 Turn the ignition key to the off position 2 Push down on the fuel shut off lever to release the Control Handle 13 3 Turn the fuel valve to its OFF position Start Procedure Before starting the...

Страница 10: ...sition and cause the Generator to shut down The Pilot Light will shut off to show that the Circuit Protector has been tripped Disconnect all devices and press the Circuit Breaker back up to reset the...

Страница 11: ...ain plug and tighten it 4 Refill the oil to the proper level following the instructions under the Starting the Engine section Air Filter element Maintenance 1 Routine maintenance to the air cleaner he...

Страница 12: ...ar operation of the engine and equipment After initial 20 operation hour period a Change engine oil Every 50 operation hours a Replace fuel filter Every 100 operation Hours a Change engine oil or with...

Страница 13: ...pecific altitude 1 Reduce load 2 Check oil level and drain excess from crankcase 3 Treat engine with biocide 4 Have the Generator serviced by a qualified mechanic 5 Replace air filter 6 Have a qualifi...

Страница 14: ...Service Manual 5500W Silent Diesel Generator with Electric Start Engine Diagram 12...

Страница 15: ...Service Manual 5500W Silent Diesel Generator with Electric Start External Components Diagram 13...

Страница 16: ...NEEDLE BEARING 1 82 BALANCE GEAR 1 22 CYLINDER HEAD STUD SHORT 2 83 BALL BEARING 2 23 SPECIAL WASHER 4 84 CRANKSHAFT ASS Y 1 24 CYLINDER HEAD NUT SHORT 2 85 TIMING GEAR 1 25 CYLINDER HEAD GASKET 1 86...

Страница 17: ...SPEC ORD 1 178 GOVERNOR LEVER 1 258 2 FLANGE HD HEX BOLT 6 179 WASHER 1 259 FRONT COVER 1 179 2 COPPER WASHER 1 261 FLANGE HD HEX BOLT 4 180 OIL SEAL 1 262 COMPLETE ROTOR 1 181 PIN 2 263 WASHER 1 182...

Страница 18: ...9 BATTERY PAD 1 332 RIPPLE PIPE GASKET SPEC ORD 1 290 HOOK BOLT 2 333 AIR FILTER SHOCK ABS SPEC ORD 1 291 BATTERY HOLDER 1 336 PAN HD SCREW 3 291 2 FLANGE HD HEX BOLT 4 338 FUEL LINE SHOCK ABSORBER 1...

Отзывы: