background image

4

5

• Never allow red and black clamps to touch each other or another common metal conductor — this 

could cause damage to the unit and/or create a sparking/explosion hazard.

a) For negative-grounded systems, connect the POSITIVE (RED) clamp to the POSITIVE 

ungrounded battery post and the NEGATIVE (BLACK) clamp to the vehicle chassis or engine block 

away from the battery. Do not connect the clamp to the carburetor, fuel lines or sheet-metal body 

parts. Connect to a heavy gauge metal part of the frame or engine block. Refer to the automobile 

owner’s manual.

b) For positive-grounded systems, connect the NEGATIVE (BLACK) clamp to the NEGATIVE 

ungrounded battery post and the POSITIVE (RED) clamp to the vehicle chassis or engine block 

away from the battery. Do not connect the clamp to the carburetor, fuel lines or sheet-metal body 

parts. Connect to a heavy gauge metal part of the frame or engine block. Refer to the automobile 

owner’s manual.

• If the connections to the battery’s POSITIVE and NEGATIVE terminals are incorrect, the Reverse 

Polarity Indicator will light (red) and the unit will sound a continuous alarm until the clamps are 

disconnected. Disconnect clamps and reconnect to battery with correct polarity.

• Always disconnect the negative (Black) jumper cable first, followed by the positive (Red) jumper 

cable, except for positive grounded systems.

• This system is designed to be used only on vehicles with a 12 volt DC battery system. Do not 

connect to a 6 volt or 24 volt battery system.

• This system is not designed to be used as a replacement for a vehicular battery. Do not attempt to 

operate a vehicle that does not have a battery installed.

• Excessive engine cranking can damage a vehicle’s starter motor. If the engine fails to start after the 

recommended number of attempts, discontinue jump-start procedures and look for other problems 

that may need to be corrected.

• Do not use this jump-starter on a watercraft. It is not qualified for marine applications.

SPECIFIC SAFETY INSTRUCTIONS FOR COMPRESSORS

CAUTION: TO REDUCE THE RISK OF INJURY OR PROPERTY DAMAGE: 

Never leave the 

compressor unattended while in use.

WARNING: BURST HAZARD:

• Carefully follow instructions on articles to be inflated.

• Never exceed recommended pressures. If no pressure is given, contact the manufacturer of the 

article before inflating. Bursting articles can cause serious injury.

• Always check pressure with the pressure gauge.

CAUTION: TO REDUCE THE RISK OF PROPERTY DAMAGE:

Do not operate compressor continuously for longer than approximately 10 minutes, depending on 

ambient temperatures, as it may overheat. In such event, compressor may automatically shut down. 

Turn off the Compressor Power Switch immediately and restart after a cooling down period of 

approximately 30 minutes.

FIRST AID

• 

SKIN: 

If battery acid comes in contact with skin, rinse immediately with water, then wash thoroughly 

with soap and water. If redness, pain, or irritation occurs, seek immediate medical attention.

• 

EYES:

 If battery acid comes in contact with eyes, flush eyes immediately, for a minimum of 15 

minutes and seek immediate medical attention.

• 

Read And Understand This Instruction Manual Before Using This Unit.

SAVE THESE INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF INJURY:

Follow these instructions and those published by the battery manufacturer and manufacturer of any 

equipment you intend to use with this unit. Review cautionary markings on these products and on 

engine.

INTRODUCTION

Thank you for choosing the 

Black & Decker 350 Amp Jump-Starter with Compressor

Please read this guide carefully before use to ensure optimum performance and avoid damage to the 

unit or items that you are using it with. 

• Remove personal metal items such as rings, bracelets, necklaces and watches when working with a 

lead acid battery. A lead acid battery can produce a short circuit current high enough to weld a ring, 

or similar metal object, to skin, causing a severe burn.

• Place this unit as far away from the battery as cables permit.

• Never allow battery acid to come in contact with this unit.

• Do not operate this unit in a closed area or restrict ventilation in any way.

• All ON/OFF switches should be in the OFF position when the unit is charging or not in use. Make 

sure all switches are in the OFF position before connection to a power source or load.

• Although this unit contains a non-spillable battery, it is recommended that the unit be kept upright 

during storage, use and recharging. To avoid possible damage that may shorten the unit’s working 

life, protect it from direct sunlight, direct heat and/or moisture.

• NEVER ATTEMPT TO JUMP-START OR CHARGE A FROZEN BATTERY.

SPECIFIC SAFETY INSTRUCTIONS FOR POWER CORDS

• 

Don’t abuse cord. 

Never carry appliance by cord or yank it to disconnect from receptacle. Keep cord 

from heat, oil, and sharp edges. Pull plug rather than cord when unplugging the unit.

• 

Ground Fault Circuit Interrupter

 (GFCI) protection should be provided on the circuits or outlets to be 

used. Receptacles are available having built in GFCI protection and may be used for this measure of 

safety.

Extension Cords

• 

An extension cord should not be used unless absolutely necessary.

 Use of an improper extension 

cord could result in a risk of fire and electric shock, and will void warranty.

• 

If an extension cord must be used, 

make sure your extension cord is in good condition. When 

using an extension cord, be sure to use one heavy enough to carry the current your product will 

draw. An undersized cord will cause a drop in line voltage resulting in loss of power and overheating. 

The following table shows the correct size to use depending on cord length and nameplate ampere 

rating. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.

Recommended Minimum AWG Size for Extension Cords for Battery Chargers

 

AC Input Rating 

American Wire Gage (AWG) Size of Cord

 

Amperes 

Length of Cord, feet (m)

 Equal to or  But less  

25 (7.6)  50 (15.2)  100 (30.5) 150 (45.6)

 greater  than 

than

  0 

 2 

18 

18 

18 

16

  2 

 3 

18 

18 

16 

14

  3 

 4 

18 

18 

16 

14

  4 

 5 

18 

18 

14 

12

  5 

 6 

18 

16 

14 

12

  6 

 8 

18 

16 

12 

10

  8 

10 

18 

14 

12 

10

 10 

12 

16 

14 

10 

 8

 12 

14 

16 

12 

10 

 8

 14 

16 

16 

12 

10 

 8

 16 

18 

14 

12 

 8 

 8

 18 

20 

14 

12 

 8 

 6

• 

Power Cord Safety:

  This appliance has a polarized plug (one blade is wider than the other) as a safety feature. This plug 

will fit into a polarized outlet only one way. If the plug does not fit fully into the outlet, reverse the 

plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature.

SPECIFIC SAFETY INSTRUCTIONS FOR JUMP STARTERS

CAUTION: TO REDUCE THE RISK OF INJURY OR PROPERTY DAMAGE:

• NEVER ATTEMPT TO JUMP-START A FROZEN BATTERY.

• Jump-start procedures should only be performed in a safe, dry, well-ventilated area.

• Vehicles that have on-board computerized systems may be damaged if vehicle battery is jump-

started. Before jump-starting, read the vehicle’s owner’s manual to confirm that external-starting 

assistance is suitable.

• Always store battery clamps when not in use. Never touch battery clamps together. This can cause 

dangerous sparks, power arcing and/or explosion.

JS700TKCB_ManualENSP_091613.indd   4-5

9/16/2013   11:20:59 AM

Содержание JS700TKCB

Страница 1: ... Global LLC 595 S Federal Highway Suite 210 Boca Raton FL 33432 www Baccusglobal com 1 877 571 2391 350A JUMP STARTER WITH COMPRESSOR INSTRUCTION MANUAL Catalog Number JS700TKCB SAVE THIS MANUAL FOR FUTURE REFERENCE Cat JS700TKCB September 2013 Copyright 2013 Baccus Global LLC Printed in China Thank you for choosing Black Decker Go to www Baccusglobal com to register your new product PLEASE READ B...

Страница 2: ... of accidental contact with battery acid Have plenty of fresh water and soap nearby in case battery acid contacts skin If battery acid contacts skin or clothing wash immediately with soap and water for at least 10 minutes and get medical attention immediately Never smoke or allow a spark or flame in vicinity of vehicle battery engine or this unit This device complies with part 15 of the FCC rules ...

Страница 3: ... Black Decker 350 Amp Jump Starter with Compressor Please read this guide carefully before use to ensure optimum performance and avoid damage to the unit or items that you are using it with Remove personal metal items such as rings bracelets necklaces and watches when working with a lead acid battery A lead acid battery can produce a short circuit current high enough to weld a ring or similar meta...

Страница 4: ...t the AC adapter cover located on the back of the unit and connect an extension cord to the unit Plug the other end of the cord into a standard 120 volt AC wall outlet 2 Charge until the green Battery Status LED Indicator lights solid or flashes 3 Disconnect the extension cord JUMP STARTER This Jump Starter is equipped with an On Off Power Switch Once the connections are properly made turn the swi...

Страница 5: ...l or moving part Refer to the automobile owner s manual 6 When clamps are connected properly turn the Jump Starter Power Switch to ON 7 Turn ON the ignition and crank the engine in 5 6 second bursts until engine starts 8 Turn the Jump Starter Power Switch back to the OFF position 9 Disconnect the negative engine or chassis clamp first then disconnect the positive battery clamp WARNING TO REDUCE TH...

Страница 6: ...pressor may be overheated Press the compressor on off button to turn the compressor off Restart after a cooling down period of approximately 30 minutes 12VDC Accessory Outlet will not power appliance Make sure the appliance does not draw more than 5 amps Check that Jump Starter has a full charge Recharge unit if necessary LED Area Light does not come on Make sure the LED Area Light ON OFF button i...

Страница 7: ...probados por el partido responsable de conformidad podían anular la autoridad del usuario para funcionar el equipo NORMAS DE SEGURIDAD DEFINICIONES PELIGRO Indica una situación de peligro inminente que si no se evita provocará la muerte o lesiones graves ADVERTENCIA Indica una situación de peligro potencial que si no se evita podría provocar la muerte o lesiones graves PRECAUCIÓN Indica una situac...

Страница 8: ...ipo emplea piezas interruptores y relés que producen arcos o chispas Por lo tanto si utiliza la unidad en una cochera o un área cerrada DEBE colocarla a no menos de 457 mm 18 pulgadas por encima del piso LOS NIÑOS NO DEBEN UTILIZAR ESTA UNIDAD SÓLO LOS ADULTOS DEBEN OPERARLA ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO No opere cerca de materiales vapores o gases inflamables No lo exponga al cal...

Страница 9: ...ontinua hasta que las pinzas sean desconectados Desconecte las pinzas y vuelva a conectarlas a la batería con la polaridad correcta Siempre desconecte primero el cable del puente del negativo negro y luego el cable del puente del positivo rojo excepto para los sistemas con positivo a tierra Este sistema está diseñado para ser utilizado únicamente en vehículos con sistema de batería de CC de 12 vol...

Страница 10: ...puede retardar el proceso de recarga Importante Si usted sabe que la unidad está descargada pero el estado de la batería que LED se iluminan como si completamente cargada cuando se conecta a una fuente de alimentación de carga esto puede deberse a la batería interna con una alta impedancia El fabricante sugiere dejar la unidad en el cargo por un período de 24 48 horas antes de su uso PRECAUCIÓN PA...

Страница 11: ...a parte posterior de la unidad cerca del medidor de presión El medidor de presión de aire se encuentra en la parte posterior de la unidad por encima del panel de control El compresor puede funcionar el tiempo suficiente para llenar hasta 3 llantas de tamaño medio antes de que la batería debe ser recargada El compresor se puede utilizar quitando la manguera de aire del receptáculo de almacenamiento...

Страница 12: ...muníquese con el fabricante para cualquier información que pueda necesitar ELIMINACIÓN DE LA BATERÍA Contiene una batería de plomo ácido sellada anti derrame que no requiere mantenimiento la cual debe ser eliminada de manera correcta Se requiere reciclado comuníquese con su autoridad local para más información El incumplimiento de las reglamentaciones locales estatales y federales pueden provocar ...

Отзывы: