Door Sensor associates with other devices through Z-wave network directly The alarm gateway or Z-wave
controller does not take part in communications.
Restore the Sensor (door sensor) to Factory Default Settings
Reset will delete all information on the Z-Wave network or Z-Wave controller, and restore the sensor to
factory default settings.
1. Remove the cover of door sensor main body.
2. Make sure the sensor is connected to power source.
3. Press and hold the reset button for 10 seconds, LED light will flash red once.
4. Release the button.
NOTE
When the Door Sensor is being restored to factory default settings, please make sure power source is
connected.
Battery Usage Tips
Battery life of the door sensor is approximately 10 years at factory default settings.
The current battery level is displayed in the gateway. Red battery icon means the battery needs to be replaced.
In order to avoid tamper detection, while replacing the battery, please disconnect any association of the door
sensor with other devices.
Note
Door sensor is battery powered. Using batteries other than specified may result in explosion. Dispose of
properly, please observe environmental protection rules.
Advanced Configuration
1. Configuring the OFF Delay
This configuration parameter that can be used to adjust the amount of delay before the OFF command is
transmitted. This parameter can be configured with the value of 0 through 65535, where 0 means send OFF
command immediately and 65535 means 65535 seconds of delay.
Function:
On/Off Duration.
Parameter Number:
1.
Parameter Size:
2 Byte
Available Settings
:
0-65535 (in seconds, each 1s).
Default Setting:
30 (s)
2. Basic Set Level
Basic Set Command will be sent where contains a value when the door/window is opened or closed, the
receiver will take it for consideration; for instance, if a lamp module received the Basic Set Command of which
value is decisive as to how bright of dim level of lamp module shall be.
Function:
Basic Set
Parameter Number:
2
Parameter Size:
1 Byte
Available Settings
:
0, 1 - 99 or 255
0 – OFF, Alarm cancelling or turning a device off
1 - 99 or 255 – ON (Binary Switch Device)
Dim Level (Multilevel Switch Device)
Default Setting:
99
Command Classes
This Sensor(Door/Windows Detector) supports Command Classes as Below:
* COMMAND_CLASS_ZWAVEPLUS_INFO (V2)
* COMMAND_CLASS_VERSION (V2)
* COMMAND_CLASS_MANUFACTURER_SPECIFIC (V2)
* COMMAND_CLASS_DEVICE_RESET_LOCALLY (V1)
* COMMAND_CLASS_POWERLEVEL (V1)
* COMMAND_CLASS_BATTERY (V1)
* COMMAND_CLASS_ASSOCIATION (V2)
* COMMAND_CLASS_ASSOCIATION_GRP_INFO (V1)
* COMMAND_CLASS_WAKE_UP (V2)