background image

Door Sensor associates with other devices through Z-wave network directly The alarm gateway or Z-wave 

controller does not take part in communications. 

 

Restore the Sensor (door sensor) to Factory Default Settings 

Reset will delete all information on the Z-Wave network or Z-Wave controller, and restore the sensor to 

factory default settings. 

1. Remove the cover of door sensor main body. 

2. Make sure the sensor is connected to power source. 

3. Press and hold the reset button for 10 seconds, LED light will flash red once. 

4. Release the button. 

NOTE 

When the Door Sensor is being restored to factory default settings, please make sure power source is 

connected. 

 

Battery Usage Tips 

Battery life of the door sensor is approximately 10 years at factory default settings. 

The current battery level is displayed in the gateway. Red battery icon means the battery needs to be replaced. 

In order to avoid tamper detection, while replacing the battery, please disconnect any association of the door 

sensor with other devices. 

Note 

Door sensor is battery powered. Using batteries other than specified may result in explosion. Dispose of 

properly, please observe environmental protection rules. 

 

Advanced Configuration 

1. Configuring the OFF Delay 

This configuration parameter that can be used to adjust the amount of delay before the OFF command is 

transmitted. This parameter can be configured with the value of 0 through 65535, where 0 means send OFF 

command immediately and 65535 means 65535 seconds of delay. 

Function: 

On/Off Duration. 

Parameter Number: 

1. 

Parameter Size: 

2 Byte 

Available Settings

0-65535 (in seconds, each 1s). 

Default Setting: 

30 (s) 

2. Basic Set Level 

Basic Set Command will be sent where contains a value when the door/window is opened or closed, the 

receiver will take it for consideration; for instance, if a lamp module received the Basic Set Command of which 

value is decisive as to how bright of dim level of lamp module shall be. 

Function: 

Basic Set 

Parameter Number: 

Parameter Size: 

1 Byte 

Available Settings

0, 1 - 99 or 255 

0 – OFF, Alarm cancelling or turning a device off 

1 - 99 or 255 – ON (Binary Switch Device) 

Dim Level (Multilevel Switch Device) 

Default Setting: 

99 

 

Command Classes 

This Sensor(Door/Windows Detector) supports Command Classes as Below: 

* COMMAND_CLASS_ZWAVEPLUS_INFO (V2) 

* COMMAND_CLASS_VERSION (V2) 

* COMMAND_CLASS_MANUFACTURER_SPECIFIC (V2) 

* COMMAND_CLASS_DEVICE_RESET_LOCALLY (V1) 

* COMMAND_CLASS_POWERLEVEL (V1) 

* COMMAND_CLASS_BATTERY (V1) 

* COMMAND_CLASS_ASSOCIATION (V2) 

* COMMAND_CLASS_ASSOCIATION_GRP_INFO (V1) 

* COMMAND_CLASS_WAKE_UP (V2) 

Отзывы: