724-746-5500 | blackbox.com
Page 47
Chapter 6: Operation
If the COAX CABLE TEST concludes with a wire map display and
no reported errors, the cable is error free.
Press SAVE to either SAVE or NAME and SAVE the test. See
Section 6.4 for instructions. Press EXIT to discard the results.
6.4 Naming/Saving Test Results
Figure 6-47. Naming and saving test results start at this screen.
All LPV tests, whether LPV UTP, Basic UTP or coax, eventually
arrive at this screen. It is here where you decide to SAVE the test
in PRINTER MEMORY (with or without a custom NAME).
REVIEW TEST:
Review test results before they are SAVED. After
reviewing the test results, you can return to this screen.
SAVE READINGS:
Store the results from the latest test in
PRINTER MEMORY for later printing. The next sequential
Reading Number (1–250) is automatically assigned along with
any NAME that you created (see EDIT TEST NAME below).
Creating a name is not required.
NOTE: The test results of all LPV cable tests can be NAMED and
STORED with the exception of LPV tests that did not
“PASS.”
LPV TEST PORT:
For LPV UTP tests only.
EDIT TEST NAME:
Create a name (not required) that is stored
with the sequential reading number. If you are going to create a
name, it must be created before the test is SAVED. See the
following page for instructions on creating a NAME.