CHAPTER 4: Operation

a

is the address of the Switch(es) that you are
sending the command to:

If you enter a number from 0 to 9 for the 

a

value, only the specific Switch that you have
selected will receive the command.

If you enter “*” (an asterisk) for the 

a

value, all of the Switches will receive the
command.

c

is the operation code:

If you enter “0” (zero) for the 

c

value, the

Pow-R-Switch(es) that receive the command
will turn OFF power to their AC outlets.

If you enter “1” (one) for the 

c

value, the

Pow-R-Switch(es) that receive the command
will turn ON power to their AC outlets.

If you enter “T” for the 

c

value, the Pow-R-

Switch(es) that receive the command will
toggle power (turn power OFF, wait a few
seconds, then turn it back ON) to their AC
outlets. This command is case-sensitive—you
must enter an uppercase “T,” not a
lowercase “t.”

If you enter “?” for the 

c

value, the Pow-R-

Switch(es) that receive the command will
return ASCII character strings indicating the
status of their AC outlets.

^M

is an abbreviation for the [CTRL] [M]
character (the ASCII carriage return, [CR]),
which you can generate by pressing the
[ENTER] or [RETURN] key.

Содержание SWI030A

Страница 1: ......

Страница 2: ......

Страница 3: ...own expense will be required to take whatever measures may be necessary to correct the interference Changes or modifications not expressly approved by the party responsible for compliance could void t...

Страница 4: ...rato el ctrico debe ser montado a la pared o al techo s lo como sea recomendado por el fabricante 8 Servicio El usuario no debe intentar dar servicio al equipo el ctrico m s all a lo descrito en las i...

Страница 5: ...una antena externa deber ser localizada lejos de las lineas de energia 16 El cable de corriente deber ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo 17 Cuidado debe...

Страница 6: ...rated 10 3 Installation 12 3 1 Selecting the Address 12 3 2 Setting the Configuration Switch 13 3 3 Linking the Modules 14 3 4 Making the Control Port Connection Pow R Switch 1M Only 15 3 5 Making the...

Страница 7: ...I Data Format 8 data bits no parity 1 stop bit fixed Flow Control None Data Rate 2400 or 9600 bps user selectable Maximum Distance RS 232 Control side 50 ft 15 2 m RS 485 Link side 2000 ft 609 6 m to...

Страница 8: ...ly Input 1 International standard IEC 320 male inlet Output 1 International standard IEC 320 female outlet Leads Signals Supported 1 2 3 4 5 and 7 RLSD DCD TD RD DTR SGND and RTS respectively see Appe...

Страница 9: ...D 4 2 x 14 x 12 7 cm Weight 2 lb 0 9 kg 1 2 Specs for Rack Tray SWI032 Configuration Holds three Pow R Switch modules side by side Material Steel Size With Pow R Switch modules installed 1 75 1U H x 1...

Страница 10: ...s 1 through 9 serve as satellites The Pow R Switch 1M s RS 232 Control Port which can be connected to a modem a PC or one of our Port Manager Switches product codes SW545A and SW546A accepts command s...

Страница 11: ...of the Pow R Switches 1M and 1S both look as illustrated in Figure 2 1 below They have three LED indicators whose functions are described beneath the picture Figure 2 1 The Pow R Switches front panel...

Страница 12: ...onnection and controls you can use to configure each Switch module Figure 2 2 The rear panel of the 120 VAC Pow R Switches SWI030A and SWI031A Figure 2 3 The rear panel of the 230 VAC Pow R Switches S...

Страница 13: ...5R socket into which you can plug a 115 VAC device that you want to switch On SWI030AE and SWI031AE models this is an IEC 320 female outlet into which you can plug a 230 VAC device that you want to sw...

Страница 14: ...tion 3 5 6 Test the Switch as described in Section 3 6 3 1 Selecting the Address Use the rotary dial on the rear panel of each Pow R Switch 1M or 1S module refer to Figure 2 3 on page 12 to set that m...

Страница 15: ...3 Power Up Default ON Last setting 4 Reserved Position 1 Data Rate Used to set the data rate communication speed for ASCII transmissions between the Pow R Switch 1M and the PC or other control device...

Страница 16: ...les After you set addresses and set all of the modules SETUP switches you can install the link cabling Run straight through pinned twisted pair or flat satin cables between the Switches Link Ports to...

Страница 17: ...ct the Switches Do not use cross pinned cable for this purpose 3 4 Making the Control Port Connection Pow R Switch 1M Only The RS 232 Control Port located on the rear panel of the Pow R Switch 1M is s...

Страница 18: ...u ll be switching are set to the ON position All of the devices you ll be switching should now be powered up and operating 3 6 Testing for Proper Installation Lastly you should perform the following t...

Страница 19: ...ressed the LINK indicator on the Pow R Switch 1M and on each Pow R Switch 1S should flash briefly If the LINK LED on any linked Switch module in the system does not flash check the following a Make ce...

Страница 20: ...that will receive the command and the eighth character is the code for the operation what you want the Switch to do The last character in the command string is an ASCII carriage return M 1 Establish...

Страница 21: ...you enter 1 one for the c value the Pow R Switch es that receive the command will turn ON power to their AC outlets If you enter T for the c value the Pow R Switch es that receive the command will tog...

Страница 22: ...the Pow R Switch 1S at address 3 send the command B X X B X X3T M To display the status of all linked Pow R Switch modules send the command B X X B X X M NOTE The Pow R Switch 1M will not accept addi...

Страница 23: ...ve a complete description including The nature and duration of the problem When the problem occurs The components involved in the problem Any particular application that when used appears to create th...

Страница 24: ...The Rack Tray is designed to fit most standard instrument racks Figure A 1 Installing Pow R Switches in the Rack Tray Appendix A Accessories Modular flat satin or twisted pair cables not included Rac...

Страница 25: ...ing modular adapters Pow R Switch 1M Control Port DB9 male Straight Through Pinned Six Wire RJ 11 Modular Flat Satin EL06MS or Twisted Pair EYN725MS Cable 150 ft 45 7 m maximum length To Modem DCE To...

Страница 26: ...v Abbrev RLSD DCD 1 8 RLSD DCD RD 2 3 TD TD 3 2 RD DTR 4 20 DTR SGND 5 7 SGND RTS 7 4 RTS End to End Pinning Pow R Switch 1M Control Port to Serial Port of AT Compatible Computer Pow R Switch Computer...

Страница 27: ...witch 1M Control Port to Serial Port of Terminal or PC XT Compatible Computer Pow R Switch Terminal or Computer DB9 male DB25 male Signal Pin No Pin No Signal Abbrev Abbrev RLSD DCD 1 20 DTR RD 2 2 TD...

Страница 28: ...NOTES...

Страница 29: ...NOTES...

Страница 30: ...NOTES...

Страница 31: ......

Страница 32: ......

Отзывы: