SERIAL CONSOLE PORT MANAGER
8.2 Restoring Saved Parameters
This section describes the procedure for uploading stored parameters to the Serial
Console Port Manager.
1. Start your terminal-emulation program and access the Port Manager’s
Command Mode; if the password prompt is displayed, enter the Supervisor
Password.
2. Configure your terminal-emulation program to upload an ASCII text file.
3. Upload the ASCII text file with the saved Port Manager parameters. If
necessary, key in the file name and directory path.
4. Your terminal emulation program will send the ASCII text file to the Port
Manager. When the terminal program is finished with the upload, make
certain to terminate the Upload mode.
NOTE
If the Port Manager detects an error in the parameters file, it will respond
with the “Invalid Parameter” message. If an error message is received,
carefully check the contents of the parameters file, correct the problem,
and then repeat the upload procedure.
5. If the parameter-upload procedure is successful, the Port Manager will send a
confirmation message, and then return to the “APS>” command prompt.