Chapter 3: Configuration
3. Configuration
There are no DIP switch or jumper settings that need to be modified in order to operate the basic functrions of the A/B Switch.
There are, however, several parameters related to Ethernet remote access/control and the automatic switching features that are
configurable. These settings are described later in this manual.
NOTE: The internal jumpers and DIP switches inside the A/B Switch have been pre-configured at the factory and should not be
changed from their default settings. They are shown here for reference only.
Table 3-1. Jumper settings.
Jumper Position
Function
W1
1–2 position
no Ethernet control module (SW1047A)
2–3 position
Ethernet control module installed (SW1046A)
W2
1–2 position
no Ethernet control module (SW1047A)
2–3 position
Ethernet control module installed (SW1046A)
NOTE: DIP switch SW1 (resistors may be installed for “closed” positions).
Table 3-2. DIP Switch SW1 settings.
SW1 Position
Function
1 Open
Not used
1 Closed
Non-latching relays (SW1046A, SW1047A)
2 Open
No Ethernet control module (SW1047A)
2 Closed
Ethernet control module installed (SW1046A)
3–8 Open
Reserved for future use