Chapter 3: Configuration
3. Configuration
There are no DIP switch or jumper settings that need to be modified in order to operate the basic functrions of the A/B Switch.
There are, however, several parameters related to Ethernet remote access/control and the automatic switching features that are
configurable. These settings are described later in this manual.
NOTE: The internal jumpers and DIP switches inside the A/B Switch have been pre-configured at the factory and should not be
changed from their default settings. They are shown here for reference only.
Table 3-1. Jumper settings.
Jumper Position
Function
W1
1–2 position
no Ethernet control module (SW1043A-MM, SW1044A-SM)
2–3 position
Ethernet control module installed (SW1042A-MM, SW1045A-SM)
W2
1–2 position
no Ethernet control module (SW1043A-MM, SW1044A-SM)
2–3 position
Ethernet control module installed (SW1042A-MM, SW1045A-SM)
NOTE: DIP switch SW1 (resistors may be installed for “closed” positions).
Table 3-2. DIP Switch SW1 settings.
SW1 Position
Function
1 Open
Not used
1 Closed
Not used
2 Open
No Ethernet control module (SW1043A-MM, SW1044A-SM)
2 Closed
Ethernet control module installed (SW1042A-MM, SW1045A-SM)
3–8 Open
Reserved for future use