background image

wel

c

ome

c

ontent

s

inst

all

ation

 

op

era

tion

sp

ecial

 

c

onfigura

tion

fur

t

er

informa

tion

®

Password setting

Password protection allows you restrict access to the system only to authorised 
personnel. A password first needs to be set and then, using the keyboard 
attached to the remote ServSwitch CX Remote module, a simple key sequence 
allows the system to be quickly and securely detached from its peripherals.

To set a password

1  Simultaneously, press the hotkeys (by default, 

 and 

) along with 

 

to enter configuration mode.

2  Press   followed by 

.

3  Now enter your new password, within the following constraints:

•  Passwords are NOT case sensitive,
•  Passwords may be any length from one character to a maximum of forty 

characters,

•  The following keys may NOT be used: 

, or 

 

4  When you have entered the password, press 

 to signal its completion.

5  Press 

 once more to exit configuration mode.

For full details about how to lock and unlock the system using your password, 
please see the 

Locking.and.unlocking.the.system

 section in the ‘Installation 

and operation’ chapter.

To clear a password (and restore factory default settings)

This procedure is applicable for the 

ServSwitch CX Remote USB

 model only. 

To clear a password (and restore factory settings) on a standard ServSwitch CX 
Remote model, use the 

F

 reset function covered within the 

Miscellaneous.

settings

 section (the ServSwitch CX Remote USB model may also be reset using 

this method). 

1  Connect the ServSwitch CX Remote module to a computer in the same 

manner as you would to carry out a flash upgrade - see 

Performing.flash.

upgrades

.

2  While power is applied, set the ServSwitch CX Remote upgrade switch SW1 

to its ON position.

3  Remove power from the ServSwitch CX Remote unit and then re-apply 

power.

4  Set the computer serial settings to the following: 19200, n, 8, 1
5  Using ‘TeraTerm’ (recommended) or an alternative terminal program, send 

“CLEAR<cr>” - in upper or lower case from the keyboard. The ServSwitch 
CX Remote unit should respond with “OK”.

6  The password is now clear and all factory default settings restored.

Mouse switching control (USB models)

In order to allow a 3 button mouse (or scroll wheel mouse) to be used to change 
channels, it is first necessary to enable the feature using the process described 
here. For details about switching using a mouse - see 

Selecting.and.using.

computers

Note: When mouse switching is enabled, the click of the centre button (or 
wheel) will not be passed to the host computer - the rotary action of a scroll 
wheel will, however, continue as normal.

To enable/disable mouse switching

1  Simultaneously, press the hotkeys (by default, 

 and 

) along with 

 

to enter configuration mode.

2  To enable mouse switching: Press     
  To disable mouse switching: Press     
3  Press 

 to exit configuration mode.

Содержание ServSwitch KV1400A

Страница 1: ...Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com CUSTOMER SUPPORT INFORMATION Novem...

Страница 2: ...10 Entering using and exiting configuration mode 10 Password setting 11 Mouse switching control USB models 11 Hot plugging PS 2 style connections and mouse restoration 12 Which restore setting do I us...

Страница 3: ...ows you to make adjustments to the sharpness and brightness settings to suit your own preferences Audio equipped A or AS models required for speakers Skew compensation AS models required for full 980...

Страница 4: ...de cable 4 way jack connector to 9 way D type male serial connector not pictured Server Access Module supplied items Video PS 2 style mouse PS 2 style keyboard Audio USB keyboard mouse Sun keyboard mo...

Страница 5: ...gher frequency networks While these uneven twists work well for Ethernet signals they can impose problems for the video signals transceived by the ServSwitch CX Remote modules The SAMs send the red gr...

Страница 6: ...SAM The other end of each cable run will attach to the remote ServSwitch CX Remote module Server Access Module Category 5 5e or 6 cable to ServSwitch CX Remote module Green indicator power present Yel...

Страница 7: ...m mouse From keyboard From video monitor CX Remote module 4 Insert the output connector of the power supply into the socket at the front edge of the CX Remote module labelled POWER 5 Insert the IEC co...

Страница 8: ...ule labelled PWR 5 Insert the IEC connector of the supplied power lead into the corresponding socket of the power supply Connect the other end of the power lead to a nearby mains socket 6 Where necess...

Страница 9: ...1 OFF Normal operation ON Before power is applied Places the ServSwitch CX Remote module into flash upgrade mode so that the internal software can be changed Please see the Flash upgrade section in th...

Страница 10: ...CX Remote module will be lit To unlock the system 1 Enter the correct password and press Note Passwords are NOT case sensitive Note If an invalid password has been entered and the keyboard indicators...

Страница 11: ...he standard and hotkeys are also needed for computer tasks you can change them for another combination using switches 2 and 3 on the ServSwitch CX Remote remote module 2 OFF 3 OFF Hotkeys and default...

Страница 12: ...t function covered within the Miscellaneous settings section the ServSwitch CX Remote USB model may also be reset using this method 1 Connect the ServSwitch CX Remote module to a computer in the same...

Страница 13: ...t is likely to support the Intellimouse format If you have a Microsoft mouse then it will usually state that it is an Intellimouse on its underside label Recognising an Intellimouse driver Before hot...

Страница 14: ...d indicators Num Lock Caps Lock and Scroll Lock will now begin to flash in sequence The speed of the sequence indicates the level of the sharpness adjustment currently applied the slower the rate the...

Страница 15: ...Data signal Red video signal Green video signal Blue video signal 7 3 4 1 7 3 4 1 To use skew adjustment 1 Display a skew pattern on the appropriate computer You can either use the supplied skew patte...

Страница 16: ...responding keyboard indicators will flash rapidly to show which channel is currently selected for adjustment Num Lock for Red Caps Lock for Green and Scroll Lock for Blue Advance colour timing Retard...

Страница 17: ...llows you to check the current revision of the ServSwitch CX Remote USB firmware PC USB VIDEO PS 2 KEYBOARD PS 2 MOUSE PSU CX Remote SAM Leave the video monitor connected to the computer so that you c...

Страница 18: ...nd to establish the existing firmware details Note The computer to which each SAM is connected must be powered before the respective SAM can be accessed If the application cannot contact the module re...

Страница 19: ...is greater than the Current firmware version 5 To begin the upgrade process click the Upload Now button The progress will be shown within the dialog Should you decide not to continue with the upload...

Страница 20: ...ocket outlet close to the ServSwitch CX Remote module that it is powering Replace the power adapter with a manufacturer approved type only Do not use the power adapter if the power adapter case become...

Страница 21: ...b Increase the separation between the equipment and the receiver c Connect the equipment to an outlet on a circuit different from that to which the receiver is connected d Consult the supplier or an e...

Страница 22: ...ort the need for service to the supplier or to an authorized agent Certification notice for equipment used in Canada The Canadian Department of Communications label identifies certified equipment This...

Страница 23: ...netes que impidan el flujo de aire por los orificios de ventilaci n 10 El equipo el ctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros ap...

Страница 24: ...uration further information 23 www ctxd com Documentation by 2007 Black Box Corporation All trademarks are acknowledged Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 United States of Am...

Страница 25: ...www blackbox fr 33 1 45 606 717 33 1 45 606 747 tech blackbox fr Germany www black box de 49 811 5541 110 49 811 5541 499 techsupp black box de Italy www blackbox it 39 02 27 404 700 39 02 27 400 219...

Отзывы: