background image

34

SERVLINK™ POWER MANAGEMENT MODULE

5.3 Users

When you select “Users” from the Security menu, the dialog box shown in
Figure 5-5 appears.

Figure 5-5. The Users dialog box.

To configure Power Management Module access rights (and other security) for a
new user, click the Add User button. To change these rights for an existing user,
highlight that user’s entry in the User Names column and click the Change User
button. Either way, the Add Users dialog box shown in Figure 5-6 on the next page
will appear.

Содержание ServLINK ACRPWR

Страница 1: ...r fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Dr Lawrence PA 15055 1018 World Wide Web www blackbox com E mail info blackbox com Copyright 2000 Black Box Corporation All rights re...

Страница 2: ...there s no reason why not We carry a broad line of robust solutions for all these applications Do you have just two PCs and need an economical alternative to keeping two monitors keyboards and mice on...

Страница 3: ...crosoft Windows and Windows NT are trademarks or registered trademarks of Microsoft Corporation in the United States and or other countries SGI is a registered trademark of Silicon Graphics Inc Sun an...

Страница 4: ...nce when the equipment is operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be requi...

Страница 5: ...television reception However there is no guarantee that harmful interference will not occur in a particular installation If this equipment does cause interference to radio or television reception whi...

Страница 6: ...ato el ctrico debe ser montado a la pared o al techo s lo como sea recomendado por el fabricante 8 Servicio El usuario no debe intentar dar servicio al equipo el ctrico m s all a lo descrito en las in...

Страница 7: ...de existir una antena externa deber ser localizada lejos de las lineas de energia 16 El cable de corriente deber ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo 17 Cu...

Страница 8: ...Up 17 4 Operation 18 4 1 Controls and Connectors 18 4 2 Rebooting the ServLINK Itself 20 4 2 1 Primary Ring Reset Rebooting 20 4 2 2 Secondary Password Rebooting 20 4 3 Rebooting the Attached Devices...

Страница 9: ...ication with attached device All other indications are software based Connectors All rear mounted 1 IEC 320 male power inlet 1 IEC 320 female power outlet 3 RJ 45 female ports for serial communication...

Страница 10: ...oduct code ACRPWR in your system By daisychaining these Modules together you can control and communicate with as many as 250 devices Because the ServLINK operates completely independently of the attac...

Страница 11: ...le to DB25 male adapter This manual If anything is missing or damaged please call Black Box right away Normally you would run the Module s power patch cord from the Module to the power controlled devi...

Страница 12: ...e into the DATA IN port on the Module as shown in Figure 3 1 Figure 3 1 Attaching an RJ 45 cable to the Power Management Module 3 Plug the other end of this cable into the port marked DATA on your Ser...

Страница 13: ...constant dial in reboot access to your ServLINK unit you can connect a separate external modem and phone line to the Management Module so that you have a secondary way to reboot the ServLINK in case t...

Страница 14: ...th the Module to connect the other end of this cable to one of the ServLINK s serial ports as shown in Figure 3 4 Figure 3 4 Attaching the cable from the first PC s Module to the ServLINK 3b If this i...

Страница 15: ...cable then if necessary add the included DB9F to DB25M adapter Get any cable adapters etc that you d run from a PC s DB9M or DB25M serial port to the device Plug these into the DB9M or DB25M end of t...

Страница 16: ...configuring the Modules Figure 3 5 shows the logical layout of a ServLINK system that includes Power Management Modules and Figure 3 6 on the following page shows the physical layout of such a system...

Страница 17: ...ER MANAGEMENT MODULE Figure 3 6 A ServLINK system with Management Modules installed To optional modem To additional Power Management Modules attached to other devices and or to an optional pass throug...

Страница 18: ...ord so until you change these settings you can simply press Enter to log in Once you ve logged in pcANYWHERE loads followed by the ServLINK application Once the system has completely booted you should...

Страница 19: ...ServLINK is communicating with the Module The Power Management Module also has an unmarked recessed power output switch on its front panel By inserting a paper clip pin etc and pressing the switch you...

Страница 20: ...chain The SERIAL jack can be used to send data or files through the ServLINK to the attached power controlled device or any other RS 232 device or to receive data or files through the ServLINK from t...

Страница 21: ...le Reboot on less than 3 rings and Enable Reboot on more than 6 rings Because the ServLINK s internal modem will normally answer on the fourth ring you can call allow the line to ring twice and hang u...

Страница 22: ...r connect to it through a LAN and select Control Module Processing from the Switch menu When you do the program will poll the ServLINK s serial port and identify and list any Modules attached to it Yo...

Страница 23: ...t bar to the Host PC you want to transfer the files to and double click it to select it The ServLINK will go into Host Mode and you will be able to directly control that PC 4 Start up a file transfer...

Страница 24: ...ther supported remote access package from the ServLINK to the Remote PC The ServLINK doesn t monitor file transfers and won t be able to tell you whether a given transfer succeeded or failed Most file...

Страница 25: ...Management Modules are configured and controlled entirely through the menu system of the ServLINK s application program This program will run automatically when you power up the ServLINK and after an...

Страница 26: ...sing in the Switch menu Use this option to trigger power ON power OFF and reboot actions See Section 5 1 of this manual Control Module Configuration in the Switch menu Use this option to configure the...

Страница 27: ...soon as it displays the box the ServLINK immediately polls the COM port specified in Control Module Configuration see Section 5 2 for an attached daisychain of Power Management Modules If you ve inst...

Страница 28: ...e in the Module list For information about setting users access rights to the Power Management Modules see Section 5 3 Here s what the components of the main Control Module Processing box are for Pos...

Страница 29: ...ow serial data to pass through to and from any pass through device you ve installed at the end of the Power Management Module daisychain see step 5 in Section 3 2 Repoll Selecting this option will cau...

Страница 30: ...C or other device attached to this Power Management Module If Require Reasons for Power OFF actions is checked in the Control Module Configuration window see Section 5 2 you will be required to give a...

Страница 31: ...many as three separate clock times in military time format at which events will occur daily For example you can set the Module to power ON a PC at 0600 6 a m at the start of each day reboot it at 1730...

Страница 32: ...int for whatever reason you need to reboot the Module s attached device but you don t have quick access to the ServLINK application you can copy any file at all to the ServLINK s main C directory and...

Страница 33: ...n this box is checked users are required to provide a reason whenever they reboot or power down any device connected to a Power Management Module from the Control Module Processing Settings window see...

Страница 34: ...to If there s only one Module attached to the ServLINK this option only needs to be be set once Management Modules must be installed on COM1 or COM2 or if you install extra ports COM3 or COM4 and they...

Страница 35: ...he Users dialog box To configure Power Management Module access rights and other security for a new user click the Add User button To change these rights for an existing user highlight that user s ent...

Страница 36: ...until the Deny list for this user is complete Remember that position 001 is the first Module in the chain the Module attached to the ServLINK s serial port that controls power to the first PC not the...

Страница 37: ...ck the Enable Reboot When Less Than box to trigger a reboot on a call with just a few rings The default value is fewer than 3 rings available values are 3 to 9 rings This is the preferred reboot metho...

Страница 38: ...n alphanumeric characters and cannot contain spaces You ll also need to set the secondary modem to auto answer To trigger this kind of reboot dial the secondary modem from a PC running terminal emulat...

Страница 39: ...d of the history of the problem We will be able to provide more efficient and accurate assistance if you have a complete description including the nature and duration of the problem when the problem o...

Страница 40: ...NOTES...

Страница 41: ...NOTES...

Отзывы: