CHAPTER 3: Installation

7

Table 1. Printed Circuit-Board Switch and Strap Settings

Possible

Factory

Stap Identity

Location 

Settings

Setting

Function

MAIN DCE/DTE switch

DTE

DTE

Determines the PSD’s Main Channel

DCE

interface as either DTE (straight connection 
to a modem) or as DCE (straight connection 
to a computer or terminal).

Sub-channel

DTE

DTE

Determines the PSD’s sub-channel interface

DCE/DTE switches

DCE

as either DTE or DCE.

DATA RATE (kbps)

BR1

19.2

9.6

Selects the PSD’s internal data rate or external

(rotary switch)

14.4

clock from sub-channel 1.

9.6
7.2
4.8

NOTE: When using CLK 1 mode, the main

2.4

channel cannot be connected to a modem

1.2

working in internal clock.

CLK 1

Chas. GND

J1

CONNECT

DISCONNECT The CONNECT setting connects signal ground

DISCONNECT

to chassis ground. The DISCONNECT setting
isolates them.

PIN 24 DIS

J1A

ENABLE

ENABLE

Exits main channel when PIN 24 is disabled.

(jumpered)

DISABLE

(NO jumper)

TIME OUT

J2

1.7

108

Selects the time-out period (in seconds) after 

13.5

which the PSD will automatically disable the

108

sub-channel. Selecting DISABLE will stop 

DISABLE

the PSD from automatically disabling any 
sub-channels. 

CONTENTION

J5

RTS

RTS

Determines the sub-channel selection and

DATA

deselection.

FORMAT

J6

ASYNC

SYNC

Selects the data format.

SYNC

CLOCK

J7

NORMAL

NORMAL

Determines the source of the clock for

FROM EXT DTE

synchronous data. Set to NORMAL for 
internally derived clock. Set to FROM EXT 
DTE for externally dermined clock from a 
connected DTE.

EXT. BUFFER

S1

ON

OFF

Activates or deactivates the extra buffer.

(PSD-8 only)

S2

OFF

Содержание PSD-4

Страница 1: ...echnical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info b...

Страница 2: ...erated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measure...

Страница 3: ...ire por los orificios de ventilaci n 10 El equipo el ctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros aparatos incluyendo amplificadore...

Страница 4: ...ADEMARKS USED IN THIS MANUAL AS 400 is a registered trademark of International Business Machines Corporation Any other trademarks mentioned in this manual are acknowledged to be the property of the tr...

Страница 5: ...rnal from sub channel 1 Data Rates Asynchronous Up to 19 2 kbps Synchronous Internal Clock 1 2 2 4 4 8 7 2 9 6 14 4 or 19 2 kbps External Clock Up to 19 2 kbps Connectors IEIA RS 232 C CCITT V 24 DCE...

Страница 6: ...for longer than a configured amount of time the PSD will automatically disable that sub channel A front panel LED will illuminate to indicate that the sub channel has been automatically disabled The s...

Страница 7: ...There are two EXT BUFFER switches on the PSD 8 These are extra buffers not external buffers Use the extra buffers when the PSD is connected to equipment that cannot accept an external clock from the P...

Страница 8: ...Chas GND J1 CONNECT DISCONNECT The CONNECT setting connects signal ground DISCONNECT to chassis ground The DISCONNECT setting isolates them PIN 24 DIS J1A ENABLE ENABLE Exits main channel when PIN 24...

Страница 9: ...PSD 4 AND PSD 8 8 Figure 3 The Printed Circuit Board of the PSD 4 Figure 4 The Printed Circuit Board of the PSD 8...

Страница 10: ...ock BIT RATE rotary switch Set BRI to the correct system speed Jumper J7 If the equipment attached to the main channel is DCE strap to NORMAL If the equipment is DTE strap to FROM EXT DTE 3 Synchroniz...

Страница 11: ...the equipment attached to the sub channel 1 is DCE strap to NORMAL If the equipment is DTE strap to FROM EXT DTE 3 4 AC Power On the rear panel of your unit locate the 110 220 VAC selector Set the se...

Страница 12: ...er source and the green Power LED does not light up check the following Make sure the rear panel rocker switch is on and is lit Verify that the 110 220 selector is set correctly Unplug the unit and ch...

Страница 13: ...The back panels of the PSD 4 top and the PSD 8 bottom FUSE POWER Rocker switch to turn AC power on or off 110 220 VAC Selector Align either 110 or 220 with the arrow SCREWS Loosen these screws to tak...

Страница 14: ...N if one of the sub channel s DTR DSR is ON SUB CHANNEL CONTROL SIGNALS RTS DCD Follows the main channel RTS DCD unless the sub channel is disabled CTS In RTS contention mode selected sub channel foll...

Страница 15: ...PSD 4 AND PSD 8 14 Figure 6 Main Channel DTE with Sub Channel DCE Figure 7 Main Channel DTE with Sub Channel DTE...

Страница 16: ...CHAPTER 5 Technical Guide 15 Figure 8 Main Channel DCE with Sub Channel DCE Figure 9 Main Channel DCE with Sub Channel DTE...

Страница 17: ...1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746 Copyright 1998 Black Box Corporation All rights reserved...

Отзывы: