Black Box PSD-4 Скачать руководство пользователя страница 6

CHAPTER 2: Introduction

5

2. Introduction

The Programmable Sharing Device enables up to 4 (TL304A) or 8 (TL305A) modems or terminals to share
a master modem, multiplexor, or computer port in an asynchronous or synchronous multipoint environment.
(Asynchronous and synchronous equipment cannot be mixed on the same PSD.)

M

AIN

C

HANNEL

The main channel transmits information to all sub-channels in parallel.

S

UB

-C

HANNELS

Sub-channels contend to transmit to the main channel by activating RTS/DCD (Request to Send/Data Carrier
Detect) or by data transitions (strap-selectable). When the sub-channel is active, the sub-channel’s transmit data
and control signals are connected to the main channel. When RTS/DCD drops, data transitions stop, or 16 idle
bits are received, the PSD will disconnect and monitor other sub-channels.

Sub-channels can be disabled either manually by front-panel pushbuttons or automatically. If a sub-channel
is streaming and staying active for longer than a configured amount of time, the PSD will automatically disable
that sub-channel. A front-panel LED will illuminate to indicate that the sub-channel has been automatically
disabled. The sub-channel will be reset when RTS/DCD drops or 16 idle bits are transmitted to it from the
attached device.

C

LOCK

M

ODES

Three clock modes are supported: internal, external from the main channel, or external from sub-channel 1.

B

UFFER

A built-in-buffer compensates for phase differences between the clocks of modems connected to the sub-
channels and the PSD main-channel transmit clock.

An extra-buffer option on the PSD-8 can be activated when the PSD is connected to equipment that cannot
accept an external clock. Examples include DDs (United States) or other digital lines and modems that cannot
be set to an external clock. This additional buffer compensates for phase differences between the PSD clock
and sub-channel clock(s).

Figure 1. The Programmable Sharing Device allows multiple devices to share a master port.

RS-232 Cable

RS-232 Cable

Modem

Modem

CSU/DSU

PSD-4

AS/400

®

Dialup Line

Leased Line

Leased Line

Modem

Modem

CSU/DSU

Controllers

Содержание PSD-4

Страница 1: ...echnical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info b...

Страница 2: ...erated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measure...

Страница 3: ...ire por los orificios de ventilaci n 10 El equipo el ctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros aparatos incluyendo amplificadore...

Страница 4: ...ADEMARKS USED IN THIS MANUAL AS 400 is a registered trademark of International Business Machines Corporation Any other trademarks mentioned in this manual are acknowledged to be the property of the tr...

Страница 5: ...rnal from sub channel 1 Data Rates Asynchronous Up to 19 2 kbps Synchronous Internal Clock 1 2 2 4 4 8 7 2 9 6 14 4 or 19 2 kbps External Clock Up to 19 2 kbps Connectors IEIA RS 232 C CCITT V 24 DCE...

Страница 6: ...for longer than a configured amount of time the PSD will automatically disable that sub channel A front panel LED will illuminate to indicate that the sub channel has been automatically disabled The s...

Страница 7: ...There are two EXT BUFFER switches on the PSD 8 These are extra buffers not external buffers Use the extra buffers when the PSD is connected to equipment that cannot accept an external clock from the P...

Страница 8: ...Chas GND J1 CONNECT DISCONNECT The CONNECT setting connects signal ground DISCONNECT to chassis ground The DISCONNECT setting isolates them PIN 24 DIS J1A ENABLE ENABLE Exits main channel when PIN 24...

Страница 9: ...PSD 4 AND PSD 8 8 Figure 3 The Printed Circuit Board of the PSD 4 Figure 4 The Printed Circuit Board of the PSD 8...

Страница 10: ...ock BIT RATE rotary switch Set BRI to the correct system speed Jumper J7 If the equipment attached to the main channel is DCE strap to NORMAL If the equipment is DTE strap to FROM EXT DTE 3 Synchroniz...

Страница 11: ...the equipment attached to the sub channel 1 is DCE strap to NORMAL If the equipment is DTE strap to FROM EXT DTE 3 4 AC Power On the rear panel of your unit locate the 110 220 VAC selector Set the se...

Страница 12: ...er source and the green Power LED does not light up check the following Make sure the rear panel rocker switch is on and is lit Verify that the 110 220 selector is set correctly Unplug the unit and ch...

Страница 13: ...The back panels of the PSD 4 top and the PSD 8 bottom FUSE POWER Rocker switch to turn AC power on or off 110 220 VAC Selector Align either 110 or 220 with the arrow SCREWS Loosen these screws to tak...

Страница 14: ...N if one of the sub channel s DTR DSR is ON SUB CHANNEL CONTROL SIGNALS RTS DCD Follows the main channel RTS DCD unless the sub channel is disabled CTS In RTS contention mode selected sub channel foll...

Страница 15: ...PSD 4 AND PSD 8 14 Figure 6 Main Channel DTE with Sub Channel DCE Figure 7 Main Channel DTE with Sub Channel DTE...

Страница 16: ...CHAPTER 5 Technical Guide 15 Figure 8 Main Channel DCE with Sub Channel DCE Figure 9 Main Channel DCE with Sub Channel DTE...

Страница 17: ...1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746 Copyright 1998 Black Box Corporation All rights reserved...

Отзывы: